"_comment": "Single source of truth for BMS-EV controller facts. Update here; the documentation pages read this file at load time.",
"firmware": {
"current": "16.5.0",
"previous": "15.0.14",
"released": "2026-09-21",
"changes": [
"Generator (genset) control via SoC hysteresis relay output",
"Battery heating and cooling control with per-cell thresholds and hysteresis"
]
},
"hardware": {
"current": "HW3.1"
},
"features": {
"generator_control": {
"available": true,
"since_firmware": "16.5.0",
"soc_start_default_pct": 20,
"soc_stop_default_pct": 50,
"single_battery_only": true,
"note": "Relay output only. The generator's starter circuit needs its own relay or contactor rated for the load."
},
"thermal_control": {
"available": true,
"since_firmware": "16.5.0",
"heat_below_default_c": 5,
"cool_above_default_c": 36,
"hysteresis_default_c": 5,
"heating_hard_block_above_c": 50,
"heating_follows": "coldest cell",
"cooling_follows": "hottest cell",
"single_battery_only": true,
"interlocks": [
"Both circuits switch off if battery communication is lost",
"Heating blocked above 50 C regardless of user setting",
"Heating and cooling never run simultaneously",
"Cooling takes priority when the pack is both too hot and too cold",
"Both circuits held off for the first seconds after power-up"
],
"note": "Relay outputs only. Heater and cooling hardware need their own relays or contactors rated for the load."
}
},
"generated": "2026-09-21"
}