Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathscratch_sre_gateway.py
More file actions
133 lines (106 loc) Β· 6.8 KB
/
Copy pathscratch_sre_gateway.py
File metadata and controls
133 lines (106 loc) Β· 6.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
import re
with open(r"c:\Users\bjasw\Downloads\agriculture-ai-os\backend\src\iot\Gateway.ts", "r", encoding="utf-8") as f:
content = f.read()
# Import PowerIntelligence
content = content.replace("import { TuyaProvider } from './providers/TuyaProvider';",
"import { TuyaProvider } from './providers/TuyaProvider';\nimport { PowerIntelligenceEngine } from './engine/PowerIntelligenceEngine';")
# Add class properties
props = """ private powerEngine: PowerIntelligenceEngine;
// Idempotency cache for deduplication
private commandCache: Set<string> = new Set();
// Retry tracking Map<internalDeviceId, timeoutHandle>
private retryQueue: Map<string, any> = new Map();"""
content = content.replace('private deviceRegistry: Map<string, { provider: string, providerDeviceId: string }> = new Map();',
'private deviceRegistry: Map<string, { provider: string, providerDeviceId: string }> = new Map();\n' + props)
# Initialize PowerEngine
content = content.replace('this.registerProvider(new TuyaProvider());',
'this.registerProvider(new TuyaProvider());\n this.powerEngine = new PowerIntelligenceEngine(this);')
# Rewrite executeCommand with Idempotency and Retry logic
old_exec = """ async executeCommand(internalDeviceId: string, command: string, payload?: any): Promise<void> {
const mapping = this.deviceRegistry.get(internalDeviceId);
if (!mapping) throw new Error('Device not registered in gateway memory');
const provider = this.providers.get(mapping.provider);
if (!provider) throw new Error('Provider not loaded');
// 1. Update DB: Status = 'verification'
console.log(`[IoTGateway] Updating DB to verification state for ${internalDeviceId}`);
// 2. Dispatch command
const success = await provider.sendCommand(mapping.providerDeviceId, command, payload);
if (!success) {
console.error(`[IoTGateway] Provider failed to dispatch command to ${internalDeviceId}`);
// DB Status = 'failed'
return;
}
console.log(`[IoTGateway] Command dispatched. Awaiting async telemetry verification for ${internalDeviceId}...`);
// At this point, the HTTP request from the mobile app should return HTTP 202 Accepted.
// The mobile UI goes into a 'Pending/Starting' spinner.
// Actual status change will be pushed via WebSocket when `handleIncomingTelemetry` fires.
}"""
new_exec = """ async executeCommand(internalDeviceId: string, command: string, payload?: any, retryCount: number = 0): Promise<void> {
// 1. Idempotency Check
const idempotencyKey = `${internalDeviceId}_${command}_${Date.now() / 5000 | 0}`; // Dedupe within 5 seconds
if (this.commandCache.has(idempotencyKey) && retryCount === 0) {
console.warn(`[IoTGateway] DEDUPLICATED command ${command} for ${internalDeviceId}`);
return;
}
if (retryCount === 0) this.commandCache.add(idempotencyKey);
const mapping = this.deviceRegistry.get(internalDeviceId);
if (!mapping) throw new Error('Device not registered in gateway memory');
const provider = this.providers.get(mapping.provider);
if (!provider) throw new Error('Provider not loaded');
// 2. Event Sourcing DB Logging
console.log(`[IoTGateway] [Event Sourcing] Logging COMMAND_ISSUED: ${command} for ${internalDeviceId}`);
// 3. Dispatch
const success = await provider.sendCommand(mapping.providerDeviceId, command, payload);
if (!success) {
console.error(`[IoTGateway] Provider dispatch failed. Event Sourcing: FAULT_DETECTED`);
return;
}
console.log(`[IoTGateway] Dispatched (Retry ${retryCount}). Awaiting async telemetry verification...`);
// 4. Retry Engine (Fail-safe timeout)
if (this.retryQueue.has(internalDeviceId)) {
clearTimeout(this.retryQueue.get(internalDeviceId));
}
const timeout = setTimeout(() => {
console.warn(`[IoTGateway] π¨ TIMEOUT: No async telemetry received for ${internalDeviceId} after command ${command}`);
if (retryCount < 3) {
console.log(`[IoTGateway] Initiating Retry ${retryCount + 1} for ${internalDeviceId}`);
this.executeCommand(internalDeviceId, command, payload, retryCount + 1);
} else {
console.error(`[IoTGateway] π¨ SRE FATAL: Command ${command} permanently failed after 3 retries.`);
// Broadcast fault to Android
this.broadcastWebSocketUpdate(internalDeviceId, { status: 'fault', isRunning: false, lastHeartbeat: new Date(), rawPayload: { error: 'TELEMETRY_TIMEOUT' } });
}
}, 15000); // 15 second SRE timeout
this.retryQueue.set(internalDeviceId, timeout);
}"""
content = content.replace(old_exec, new_exec)
# Integrate Event Sourcing and Power Intelligence into Telemetry Handler
telemetry_hook = """ // 2. State Verification Logic
// If command was MOTOR_ON, we verify it actually turned on by checking amperage > threshold
if (state.isRunning && state.amperage && state.amperage > 1.0) {
console.log(`[IoTGateway] HARDWARE VERIFIED: Motor is drawing ${state.amperage}A. State confirmed.`);
// Update DB command_queue status = 'completed'
} else if (state.isRunning && state.amperage && state.amperage <= 0.1) {
console.warn(`[IoTGateway] FAULT DETECTED: Motor reports ON but drawing 0A (Dry Run / Phase Failure)`);
state.status = 'fault';
}"""
new_telemetry_hook = """ // Clear any pending Retry Timeouts since telemetry arrived
if (this.retryQueue.has(internalDeviceId)) {
clearTimeout(this.retryQueue.get(internalDeviceId));
this.retryQueue.delete(internalDeviceId);
console.log(`[IoTGateway] Async telemetry received. Cleared Retry Queue for ${internalDeviceId}`);
}
// Event Sourcing Log
// SQL: INSERT INTO device_events (event_type) VALUES ('TELEMETRY_RECEIVED')
// SRE: Run Power Intelligence Protection
this.powerEngine.evaluateTelemetry(internalDeviceId, state);
// State Verification
if (state.status !== 'fault' && state.isRunning && state.amperage && state.amperage > 1.0) {
console.log(`[IoTGateway] HARDWARE VERIFIED: ${state.amperage}A. Logging STATE_CONFIRMED.`);
} else if (state.isRunning && state.amperage && state.amperage <= 0.1) {
console.warn(`[IoTGateway] FAULT DETECTED: Dry Run (0A). Logging FAULT_DETECTED.`);
state.status = 'fault';
}"""
content = content.replace(telemetry_hook, new_telemetry_hook)
with open(r"c:\Users\bjasw\Downloads\agriculture-ai-os\backend\src\iot\Gateway.ts", "w", encoding="utf-8") as f: