Sunsynk Power Flow Card Configuration Examples

This document provides configuration examples for the Sunsynk Power Flow Card, tailored for the Deye Inverter setup in this project.

Prerequisites

To use these configurations, you must have the Sunsynk Power Flow Card installed in your Home Assistant instance.

  • Project Link: Sunsynk Power Flow Card on GitHub
  • Installation: It is recommended to install this card via HACS (Home Assistant Community Store). Search for sunsynk-power-flow-card in the frontend section.

Configuration Examples

Note: These examples are currently ready to use only for 3-phase inverters. For 1-phase inverters, you must adapt the configuration to use the entities available in the single-phase Deye integration.

Below are three different dashboard card configurations. Each example serves a different visual preference.

Example 1: Full Style (Modern) - 3-Phase

This configuration uses the full card style with a modern inverter look. It features large fonts and displays a single battery. This is suitable for a standard dashboard view where you want clear, readable information.

Full Style

type: custom:sunsynk-power-flow-card
cardstyle: full
wide: false
large_font: true
show_battery: true
show_solar: true
show_grid: true
grid_options:
  columns: full
solar:
  mppts: 2
  show_daily: true
  max_power: 12000
  pv1_name: String 1
  pv2_name: String 2
  pv1_max_power: 8000
  pv2_max_power: 4000
  efficiency: 3
  display_mode: 3
inverter:
  modern: true
  autarky: power
  auto_scale: true
  three_phase: true
  colour: "#ffffff"
battery:
  show_daily: true
  max_power: 12000
  count: 1
  hide_soc: false
  show_remaining_energy: true
  animate: true
  dynamic_colour: true
  linear_gradient: true
  remaining_energy_to_shutdown: true
  shutdown_soc_offgrid: number.deye_inverter_battery_shutdown_soc
  shutdown_soc: number.deye_inverter_battery_grid_charging_start_soc
load:
  show_daily: true
  max_power: 12000
  essential_name: Load/Home
  label_daily_load: Load Energy
grid:
  grid_name: Grid Name
  show_daily_buy: true
  show_nonessential: false
  max_power: 21000
  show_daily_sell: true
  label_daily_grid_sell: Sold Energy
  label_daily_grid_buy: Bought Energy
entities:
  inverter_status_59: sensor.deye_inverter_running_status
  priority_load_243: switch.deye_inverter_load_priority
  grid_ct_power_172: sensor.deye_inverter_grid_l1_power
  grid_ct_power_L2: sensor.deye_inverter_grid_l2_power
  grid_ct_power_L3: sensor.deye_inverter_grid_l3_power
  max_sell_power: number.deye_inverter_max_sell_power
  grid_power_169: sensor.deye_inverter_grid_power
  load_power_L1: sensor.deye_inverter_load_l1_power
  load_power_L2: sensor.deye_inverter_load_l2_power
  load_power_L3: sensor.deye_inverter_load_l3_power
  load_frequency_192: sensor.deye_inverter_load_frequency
  inverter_voltage_154: sensor.deye_inverter_output_l1_voltage
  inverter_voltage_L2: sensor.deye_inverter_output_l2_voltage
  inverter_voltage_L3: sensor.deye_inverter_output_l3_voltage
  inverter_power_175: sensor.deye_inverter_output_power
  inverter_current_164: sensor.deye_inverter_output_l1_current
  inverter_current_L2: sensor.deye_inverter_output_l2_current
  inverter_current_L3: sensor.deye_inverter_output_l3_current
  radiator_temp_91: sensor.deye_inverter_ac_temperature
  battery_voltage_183: sensor.deye_inverter_battery_voltage
  battery_soc_184: sensor.deye_inverter_battery
  battery_power_190: sensor.deye_inverter_battery_power
  battery_current_191: sensor.deye_inverter_battery_current
  battery_temp_182: sensor.deye_inverter_battery_temperature
  battery_rated_capacity: number.deye_inverter_battery_capacity
  pv1_power_186: sensor.deye_inverter_pv1_power
  pv2_power_187: sensor.deye_inverter_pv2_power
  pv1_voltage_109: sensor.deye_inverter_pv1_voltage
  pv1_current_110: sensor.deye_inverter_pv1_current
  pv2_voltage_111: sensor.deye_inverter_pv2_voltage
  pv2_current_112: sensor.deye_inverter_pv2_current
  solar_sell_247: switch.deye_inverter_solar_sell
  total_pv_generation: sensor.deye_inverter_total_pv_production
  day_pv_energy_108: sensor.deye_inverter_daily_pv_production
  day_battery_charge_70: sensor.deye_inverter_daily_battery_charge
  day_battery_discharge_71: sensor.deye_inverter_daily_battery_discharge
  day_load_energy_84: sensor.deye_inverter_daily_load_consumption
  day_grid_import_76: sensor.deye_inverter_daily_energy_bought
  day_grid_export_77: sensor.deye_inverter_daily_energy_sold
  grid_connected_status_194: binary_sensor.deye_inverter_ac_grid_relay
  use_timer_248: switch.deye_inverter_time_of_use
  prog1_time: time.deye_inverter_time_of_use_1_start
  prog2_time: time.deye_inverter_time_of_use_2_start
  prog3_time: time.deye_inverter_time_of_use_3_start
  prog4_time: time.deye_inverter_time_of_use_4_start
  prog5_time: time.deye_inverter_time_of_use_5_start
  prog6_time: time.deye_inverter_time_of_use_6_start
  prog1_capacity: number.deye_inverter_time_of_use_1_soc
  prog2_capacity: number.deye_inverter_time_of_use_2_soc
  prog3_capacity: number.deye_inverter_time_of_use_3_soc
  prog4_capacity: number.deye_inverter_time_of_use_4_soc
  prog5_capacity: number.deye_inverter_time_of_use_5_soc
  prog6_capacity: number.deye_inverter_time_of_use_6_soc
  prog1_charge: switch.deye_inverter_time_of_use_1_grid_charge
  prog2_charge: switch.deye_inverter_time_of_use_2_grid_charge
  prog3_charge: switch.deye_inverter_time_of_use_3_grid_charge
  prog4_charge: switch.deye_inverter_time_of_use_4_grid_charge
  prog5_charge: switch.deye_inverter_time_of_use_5_grid_charge
  prog6_charge: switch.deye_inverter_time_of_use_6_grid_charge

Example 2: Compact Style - 3-Phase

This version uses the compact card style. It is designed to take up less space on the dashboard while still providing essential information. The inverter icon is set to the deye style (modern: false and model: deye).

Compact Style

type: custom:sunsynk-power-flow-card
cardstyle: compact
wide: false
large_font: true
show_battery: true
show_solar: true
show_grid: true
grid_options:
  columns: full
solar:
  mppts: 2
  show_daily: true
  max_power: 12000
  pv1_name: String 1
  pv2_name: String 2
  pv1_max_power: 8000
  pv2_max_power: 4000
  efficiency: 3
  display_mode: 3
inverter:
  modern: false
  autarky: energy
  auto_scale: true
  three_phase: true
  model: deye
  colour: "#ffffff"
battery:
  show_daily: true
  max_power: 12000
  count: 1
  hide_soc: false
  show_remaining_energy: true
  animate: true
  dynamic_colour: true
  linear_gradient: true
  remaining_energy_to_shutdown: true
  shutdown_soc_offgrid: number.deye_inverter_battery_shutdown_soc
  shutdown_soc: number.deye_inverter_battery_grid_charging_start_soc
load:
  show_daily: true
  max_power: 12000
  essential_name: Load/Home
  label_daily_load: Load Energy
grid:
  grid_name: Grid Name
  show_daily_buy: true
  show_nonessential: false
  max_power: 21000
  show_daily_sell: true
  label_daily_grid_sell: Sold Energy
  label_daily_grid_buy: Bought Energy
entities:
  inverter_status_59: sensor.deye_inverter_running_status
  priority_load_243: switch.deye_inverter_load_priority
  grid_ct_power_172: sensor.deye_inverter_grid_l1_power
  grid_ct_power_L2: sensor.deye_inverter_grid_l2_power
  grid_ct_power_L3: sensor.deye_inverter_grid_l3_power
  max_sell_power: number.deye_inverter_max_sell_power
  grid_power_169: sensor.deye_inverter_grid_power
  load_power_L1: sensor.deye_inverter_load_l1_power
  load_power_L2: sensor.deye_inverter_load_l2_power
  load_power_L3: sensor.deye_inverter_load_l3_power
  load_frequency_192: sensor.deye_inverter_load_frequency
  inverter_voltage_154: sensor.deye_inverter_output_l1_voltage
  inverter_voltage_L2: sensor.deye_inverter_output_l2_voltage
  inverter_voltage_L3: sensor.deye_inverter_output_l3_voltage
  inverter_power_175: sensor.deye_inverter_output_power
  inverter_current_164: sensor.deye_inverter_output_l1_current
  inverter_current_L2: sensor.deye_inverter_output_l2_current
  inverter_current_L3: sensor.deye_inverter_output_l3_current
  radiator_temp_91: sensor.deye_inverter_ac_temperature
  battery_voltage_183: sensor.deye_inverter_battery_voltage
  battery_soc_184: sensor.deye_inverter_battery
  battery_power_190: sensor.deye_inverter_battery_power
  battery_current_191: sensor.deye_inverter_battery_current
  battery_temp_182: sensor.deye_inverter_battery_temperature
  battery_rated_capacity: number.deye_inverter_battery_capacity
  pv1_power_186: sensor.deye_inverter_pv1_power
  pv2_power_187: sensor.deye_inverter_pv2_power
  pv1_voltage_109: sensor.deye_inverter_pv1_voltage
  pv1_current_110: sensor.deye_inverter_pv1_current
  pv2_voltage_111: sensor.deye_inverter_pv2_voltage
  pv2_current_112: sensor.deye_inverter_pv2_current
  solar_sell_247: switch.deye_inverter_solar_sell
  total_pv_generation: sensor.deye_inverter_total_pv_production
  day_pv_energy_108: sensor.deye_inverter_daily_pv_production
  day_battery_charge_70: sensor.deye_inverter_daily_battery_charge
  day_battery_discharge_71: sensor.deye_inverter_daily_battery_discharge
  day_load_energy_84: sensor.deye_inverter_daily_load_consumption
  day_grid_import_76: sensor.deye_inverter_daily_energy_bought
  day_grid_export_77: sensor.deye_inverter_daily_energy_sold
  grid_connected_status_194: binary_sensor.deye_inverter_ac_grid_relay
  use_timer_248: switch.deye_inverter_time_of_use
  prog1_time: time.deye_inverter_time_of_use_1_start
  prog2_time: time.deye_inverter_time_of_use_2_start
  prog3_time: time.deye_inverter_time_of_use_3_start
  prog4_time: time.deye_inverter_time_of_use_4_start
  prog5_time: time.deye_inverter_time_of_use_5_start
  prog6_time: time.deye_inverter_time_of_use_6_start
  prog1_capacity: number.deye_inverter_time_of_use_1_soc
  prog2_capacity: number.deye_inverter_time_of_use_2_soc
  prog3_capacity: number.deye_inverter_time_of_use_3_soc
  prog4_capacity: number.deye_inverter_time_of_use_4_soc
  prog5_capacity: number.deye_inverter_time_of_use_5_soc
  prog6_capacity: number.deye_inverter_time_of_use_6_soc
  prog1_charge: switch.deye_inverter_time_of_use_1_grid_charge
  prog2_charge: switch.deye_inverter_time_of_use_2_grid_charge
  prog3_charge: switch.deye_inverter_time_of_use_3_grid_charge
  prog4_charge: switch.deye_inverter_time_of_use_4_grid_charge
  prog5_charge: switch.deye_inverter_time_of_use_5_grid_charge
  prog6_charge: switch.deye_inverter_time_of_use_6_grid_charge

Example 3: Wide Style with Dual Battery - 3-Phase

This configuration uses the full card style but with the wide: true option, which is ideal for wider dashboard layouts (e.g., tablets or desktop views). It also demonstrates how to configure two batteries (battery and battery2), which is useful if you have a multi-battery setup.

Wide Style

type: custom:sunsynk-power-flow-card
cardstyle: full
wide: true
large_font: true
show_battery: true
show_solar: true
show_grid: true
grid_options:
  columns: full
solar:
  mppts: 2
  show_daily: true
  max_power: 12000
  pv1_name: String 1
  pv2_name: String 2
  pv1_max_power: 8000
  pv2_max_power: 4000
  efficiency: 3
  display_mode: 3
inverter:
  modern: false
  model: deye-new
  autarky: power
  auto_scale: true
  three_phase: true
  colour: "#ffffff"
battery:
  show_daily: true
  max_power: 12000
  count: 2
  hide_soc: false
  show_remaining_energy: true
  animate: true
  dynamic_colour: true
  linear_gradient: true
  remaining_energy_to_shutdown: true
  shutdown_soc_offgrid: number.deye_inverter_battery_shutdown_soc
  shutdown_soc: number.deye_inverter_battery_grid_charging_start_soc
battery2:
  max_power: 12000
  hide_soc: false
  show_remaining_energy: true
  animate: true
  dynamic_colour: true
  linear_gradient: true
  remaining_energy_to_shutdown: true
  shutdown_soc_offgrid: number.deye_inverter_battery_shutdown_soc
  shutdown_soc: number.deye_inverter_battery_grid_charging_start_soc
load:
  show_daily: true
  max_power: 12000
  essential_name: Load/Home
  label_daily_load: Load Energy
grid:
  grid_name: Grid Name
  show_daily_buy: true
  show_nonessential: false
  max_power: 21000
  show_daily_sell: true
  label_daily_grid_sell: Sold Energy
  label_daily_grid_buy: Bought Energy
entities:
  inverter_status_59: sensor.deye_inverter_running_status
  priority_load_243: switch.deye_inverter_load_priority
  grid_ct_power_172: sensor.deye_inverter_grid_l1_power
  grid_ct_power_L2: sensor.deye_inverter_grid_l2_power
  grid_ct_power_L3: sensor.deye_inverter_grid_l3_power
  max_sell_power: number.deye_inverter_max_sell_power
  grid_power_169: sensor.deye_inverter_grid_power
  load_power_L1: sensor.deye_inverter_load_l1_power
  load_power_L2: sensor.deye_inverter_load_l2_power
  load_power_L3: sensor.deye_inverter_load_l3_power
  load_frequency_192: sensor.deye_inverter_load_frequency
  inverter_voltage_154: sensor.deye_inverter_output_l1_voltage
  inverter_voltage_L2: sensor.deye_inverter_output_l2_voltage
  inverter_voltage_L3: sensor.deye_inverter_output_l3_voltage
  inverter_power_175: sensor.deye_inverter_output_power
  inverter_current_164: sensor.deye_inverter_output_l1_current
  inverter_current_L2: sensor.deye_inverter_output_l2_current
  inverter_current_L3: sensor.deye_inverter_output_l3_current
  radiator_temp_91: sensor.deye_inverter_ac_temperature
  battery_voltage_183: sensor.deye_inverter_battery_voltage
  battery_soc_184: sensor.deye_inverter_battery
  battery_power_190: sensor.deye_inverter_battery_power
  battery_current_191: sensor.deye_inverter_battery_current
  battery_temp_182: sensor.deye_inverter_battery_temperature
  battery_rated_capacity: number.deye_inverter_battery_capacity
  battery2_voltage_183: sensor.deye_inverter_battery_voltage
  battery2_soc_184: sensor.deye_inverter_battery
  battery2_power_190: sensor.deye_inverter_battery_power
  battery2_current_191: sensor.deye_inverter_battery_current
  battery2_temp_182: sensor.deye_inverter_battery_temperature
  battery2_rated_capacity: number.deye_inverter_battery_capacity
  pv1_power_186: sensor.deye_inverter_pv1_power
  pv2_power_187: sensor.deye_inverter_pv2_power
  pv1_voltage_109: sensor.deye_inverter_pv1_voltage
  pv1_current_110: sensor.deye_inverter_pv1_current
  pv2_voltage_111: sensor.deye_inverter_pv2_voltage
  pv2_current_112: sensor.deye_inverter_pv2_current
  solar_sell_247: switch.deye_inverter_solar_sell
  total_pv_generation: sensor.deye_inverter_total_pv_production
  day_pv_energy_108: sensor.deye_inverter_daily_pv_production
  day_battery_charge_70: sensor.deye_inverter_daily_battery_charge
  day_battery_discharge_71: sensor.deye_inverter_daily_battery_discharge
  day_load_energy_84: sensor.deye_inverter_daily_load_consumption
  day_grid_import_76: sensor.deye_inverter_daily_energy_bought
  day_grid_export_77: sensor.deye_inverter_daily_energy_sold
  grid_connected_status_194: binary_sensor.deye_inverter_ac_grid_relay
  use_timer_248: switch.deye_inverter_time_of_use
  prog1_time: time.deye_inverter_time_of_use_1_start
  prog2_time: time.deye_inverter_time_of_use_2_start
  prog3_time: time.deye_inverter_time_of_use_3_start
  prog4_time: time.deye_inverter_time_of_use_4_start
  prog5_time: time.deye_inverter_time_of_use_5_start
  prog6_time: time.deye_inverter_time_of_use_6_start
  prog1_capacity: number.deye_inverter_time_of_use_1_soc
  prog2_capacity: number.deye_inverter_time_of_use_2_soc
  prog3_capacity: number.deye_inverter_time_of_use_3_soc
  prog4_capacity: number.deye_inverter_time_of_use_4_soc
  prog5_capacity: number.deye_inverter_time_of_use_5_soc
  prog6_capacity: number.deye_inverter_time_of_use_6_soc
  prog1_charge: switch.deye_inverter_time_of_use_1_grid_charge
  prog2_charge: switch.deye_inverter_time_of_use_2_grid_charge
  prog3_charge: switch.deye_inverter_time_of_use_3_grid_charge
  prog4_charge: switch.deye_inverter_time_of_use_4_grid_charge
  prog5_charge: switch.deye_inverter_time_of_use_5_grid_charge
  prog6_charge: switch.deye_inverter_time_of_use_6_grid_charge