Add remote mode control. - #148

Open
lutorm wants to merge 1 commit into
Lewa-Reka:mainfrom
lutorm:remote
Open

lutorm wants to merge 1 commit into
Lewa-Reka:mainfrom
lutorm:remote

Conversation

@lutorm

@lutorm lutorm commented Sep 27, 2026 •

Copy link
Copy Markdown

Description

Add inverter remote mode modbus registers. I have tested this on my SUN-15K-SG01HP3-EU-AM2 and I'm now using it to control the inverter from my EMHASS optimization.

Changes relate to

  • Docs
  • Deye 3P LP
  • Deye 3P HV
  • Deye 1P LP
  • Other

I only have a 3P HV inverter but I suspect this is common for all inverter types.

Summary by Sourcery

New Features:

  • Add configurable Deye 3-phase inverter remote-mode controls for selecting control strategies and setting battery, phase output, and solar power targets through Modbus.

@Lewa-Reka

Copy link
Copy Markdown
Owner

First of all, thanks for your PR. Good job!

But to be honest, I didn't add this before on purpose. Are you aware of all the drawbacks of the remote mode?

I think we can try to merge this, but it might be a good idea to add a dedicated documentation file and explain how it works. The most important part is describing all the risks for users.

@lutorm

lutorm commented Oct 4, 2026 via email

Copy link
Copy Markdown
Author

@Lewa-Reka

Copy link
Copy Markdown
Owner

@sourcery-ai review

@sourcery-ai

sourcery-ai Bot commented Oct 10, 2026

Copy link
Copy Markdown

Reviewer's Guide

Introduces Modbus-backed controls for operating the inverter in remote mode, including control-mode selection and scaled battery, phase-power, watchdog, and solar-power parameters, and wires them into the 3-phase inverter configuration.

File-Level Changes

Change Details Files
Adds a reusable remote-control Modbus package and enables it for the 3-phase inverter configuration.
  • Includes the new remote package in the inverter YAML.
  • Defines select entities for remote mode, output-power control mode, battery-side control, and phase control.
  • Defines numeric controls for watchdog timing, battery voltage/current/power/SOC, per-phase or combined inverter output power, and maximum solar power.
  • Maps each entity to the documented Modbus registers with appropriate scaling, signedness, units, limits, and write-multiple support.
pv_inverter/deye_hybrid_3p_lv.yaml
pv_inverter/packages/deye_hybrid_3p/remote.yaml

Tips and commands

Interacting with Sourcery

  • Trigger a new review: Comment @sourcery-ai review on the pull request.
  • Continue discussions: Reply directly to Sourcery's review comments.
  • Generate a GitHub issue from a review comment: Ask Sourcery to create an
    issue from a review comment by replying to it. You can also reply to a
    review comment with @sourcery-ai issue to create an issue from it.
  • Generate a pull request title: Write @sourcery-ai anywhere in the pull
    request title to generate a title at any time. You can also comment
    @sourcery-ai title on the pull request to (re-)generate the title at any time.
  • Generate a pull request summary: Write @sourcery-ai summary anywhere in
    the pull request body to generate a PR summary at any time exactly where you
    want it. You can also comment @sourcery-ai summary on the pull request to
    (re-)generate the summary at any time.
  • Generate reviewer's guide: Comment @sourcery-ai guide on the pull
    request to (re-)generate the reviewer's guide at any time.
  • Resolve all Sourcery comments: Comment @sourcery-ai resolve on the
    pull request to resolve all Sourcery comments. Useful if you've already
    addressed all the comments and don't want to see them anymore.
  • Dismiss all Sourcery reviews: Comment @sourcery-ai dismiss on the pull
    request to dismiss all existing Sourcery reviews. Especially useful if you
    want to start fresh with a new review - don't forget to comment
    @sourcery-ai review to trigger a new review!

Customizing Your Experience

Access your dashboard to:

  • Enable or disable review features such as the Sourcery-generated pull request
    summary, the reviewer's guide, and others.
  • Change the review language.
  • Add, remove or edit custom review instructions.
  • Adjust other review settings.

Getting Help

@sourcery-ai sourcery-ai Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Hey - I've found 5 issues

Prompt for AI Agents
Please address the comments from this code review:

## Individual Comments

### Comment 1
<location path="pv_inverter/packages/deye_hybrid_3p/remote.yaml" line_range="5" />
<code_context>
+  - platform: modbus_controller
+    use_write_multiple: true
+    modbus_controller_id: ${modbus_controller_id}
+    id: remote_mode
+    name: "Remote mode"
+    address: 1100
</code_context>
<issue_to_address>
**Remote setpoints survive disconnect**

When home Assistant disconnects while remote mode is enabled and the watchdog has not expired, `set_safe_modbus_registers` writes the existing safe settings but never disables `remote_mode`, so the inverter continues applying its last remote setpoints instead of those safe settings until the watchdog expires.

Disable `remote_mode` in the safe-mode sequence.
</issue_to_address>

### Comment 2
<location path="pv_inverter/packages/deye_hybrid_3p/remote.yaml" line_range="18" />
<code_context>
+  - platform: modbus_controller
+    use_write_multiple: true
+    modbus_controller_id: ${modbus_controller_id}
+    id: inverter_output_power_control_mode
+    name: "Inverter output power control mode"
+    address: 1104
</code_context>
<issue_to_address>
**Mode switches use stale setpoints**

When a client switches to per-phase control while changing its phase setpoints, or a Modbus write fails partway through those changes, `inverter_output_power_control_mode` can enable per-phase control before the separate phase setpoint writes complete, so the inverter applies previously stored phase values in the meantime; a dropped write leaves the new mode using a mixed set of values. Update the setpoints before switching modes, or provide a grouped update that switches modes last.

Apply all setpoints first and switch the active control mode last, ideally through one coordinated update.

Also at `pv_inverter/packages/deye_hybrid_3p/remote.yaml:117-164`.
</issue_to_address>

### Comment 3
<location path="pv_inverter/packages/deye_hybrid_3p/remote.yaml" line_range="68" />
<code_context>
+    id: battery_constant_voltage_mode
+    name: "Battery constant voltage mode"
+    min_value: 0
+    max_value: 1000
+    step: 0.1
+    unit_of_measurement: "V"
</code_context>
<issue_to_address>
**Unsupported battery targets are accepted**

When a caller sets the remote battery voltage above the applicable battery limit, the 0–1000 V range permits writing unsupported targets to register 1107; 3P LV controls are bounded to 38–61 V and HV controls to 710 V, so the inverter cannot apply an out-of-range remote setpoint reliably.

Constrain the accepted maximum to the applicable LV or HV battery-voltage limit.

Also at `pv_inverter/deye_hybrid_3p_lv.yaml:40`.
</issue_to_address>

### Comment 4
<location path="pv_inverter/packages/deye_hybrid_3p/remote.yaml" line_range="55-61" />
<code_context>
+  - platform: modbus_controller
+    use_write_multiple: true
+    modbus_controller_id: ${modbus_controller_id}
+    id: remote_mode_watchdog_time
+    name: "Remote mode watchdog time"
+    min_value: 10
+    step: 1
+    address: 1101
+    value_type: U_WORD
+
+  - platform: modbus_controller
+    use_write_multiple: true
</code_context>
<issue_to_address>
**Remote control times out**

When remote mode remains enabled past the configured watchdog interval without another write, the inverter's watchdog expires the remote-control session, so the configured remote mode stops applying and the inverter no longer follows the caller's setpoints.

Add a periodic refresh of the remote-control session before the watchdog expires, or make the expected refresh responsibility explicit to callers.
</issue_to_address>

### Comment 5
<location path="pv_inverter/packages/deye_hybrid_3p/remote.yaml" line_range="57" />
<code_context>
+    modbus_controller_id: ${modbus_controller_id}
+    id: remote_mode_watchdog_time
+    name: "Remote mode watchdog time"
+    min_value: 10
+    step: 1
+    address: 1101
</code_context>
<issue_to_address>
**Watchdog timeout is capped at 100 seconds**

When a caller needs a watchdog duration above 100 seconds, with `max_value` omitted, the number entity defaults to 100 even though register 1101 is a `U_WORD`, so callers cannot configure a longer watchdog timeout.

Set `max_value` to permit the longer watchdog durations supported by the register.
</issue_to_address>

Sourcery assessment

Needs a human reviewer. 5 findings to address first, and this adds direct Modbus writes for inverter operating mode, battery voltage/current/SOC, and phase power limits. An incorrect register mapping or value could cause unwanted charging, discharging, power output, or an outage, and reverting the configuration would not necessarily restore values already written to the inverter.

Blocking findings: pv_inverter/packages/deye_hybrid_3p/remote.yaml:5, pv_inverter/packages/deye_hybrid_3p/remote.yaml:18, pv_inverter/packages/deye_hybrid_3p/remote.yaml:68, pv_inverter/packages/deye_hybrid_3p/remote.yaml:61, pv_inverter/packages/deye_hybrid_3p/remote.yaml:57


Sourcery is free for open source - if you like our reviews please consider sharing them ✨

Comment thread pv_inverter/packages/deye_hybrid_3p/remote.yaml
- platform: modbus_controller
use_write_multiple: true
modbus_controller_id: ${modbus_controller_id}
id: inverter_output_power_control_mode

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Medium · Mode switches use stale setpoints

When a client switches to per-phase control while changing its phase setpoints, or a Modbus write fails partway through those changes, inverter_output_power_control_mode can enable per-phase control before the separate phase setpoint writes complete, so the inverter applies previously stored phase values in the meantime; a dropped write leaves the new mode using a mixed set of values. Update the setpoints before switching modes, or provide a grouped update that switches modes last.

Apply all setpoints first and switch the active control mode last, ideally through one coordinated update.

Also at pv_inverter/packages/deye_hybrid_3p/remote.yaml:117-164.

Prompt for AI agents
In `pv_inverter/packages/deye_hybrid_3p/remote.yaml` at line 18:

**Mode switches use stale setpoints**

When a client switches to per-phase control while changing its phase setpoints, or a Modbus write fails partway through those changes, `inverter_output_power_control_mode` can enable per-phase control before the separate phase setpoint writes complete, so the inverter applies previously stored phase values in the meantime; a dropped write leaves the new mode using a mixed set of values. Update the setpoints before switching modes, or provide a grouped update that switches modes last.

Apply all setpoints first and switch the active control mode last, ideally through one coordinated update.

Also at `pv_inverter/packages/deye_hybrid_3p/remote.yaml:117-164`.

Copy link
Copy Markdown
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Yes, switching the control mode should be done such that the setpoints are written first and the mode change last. I'm not sure that's the job of this package. The question of a modbus write fail is interesting though, is there a way to block several register updates such that they all succeed or fail together?

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Not with the normal number and select entities. In the current file, use_write_multiple: true makes each individual entity use Modbus function 16, but it does not combine writes made to separate entities into one transaction. ESPHome documents this as selecting the multiple-register function for that component’s write, not as providing transaction or rollback semantics. (ESPHome documentation)

A custom ESPHome lambda/script can send one function-16 command containing the contiguous registers. This repository already uses that approach in time_sync.yaml. For this case, the safest sequence would be:

  1. Send registers 1105–1115 together.
  2. Only after that succeeds, write register 1104 to change the active control mode.

That prevents a failed setpoint write from activating the new mode, although it still cannot guarantee rollback if the inverter applies the write and the response is lost. Modbus defines request/reply transactions and function 16, but does not provide a general multi-request commit/rollback mechanism; whether a single function-16 write is internally atomic is device-specific. (Modbus Application Protocol Specification)

For EMHASS, I would expose a single coordinated action/script for changing the mode and its setpoints, rather than relying on clients to update the independent entities in the correct order.

id: battery_constant_voltage_mode
name: "Battery constant voltage mode"
min_value: 0
max_value: 1000

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Medium · Unsupported battery targets are accepted

When a caller sets the remote battery voltage above the applicable battery limit, the 0–1000 V range permits writing unsupported targets to register 1107; 3P LV controls are bounded to 38–61 V and HV controls to 710 V, so the inverter cannot apply an out-of-range remote setpoint reliably.

Constrain the accepted maximum to the applicable LV or HV battery-voltage limit.

Also at pv_inverter/deye_hybrid_3p_lv.yaml:40.

Prompt for AI agents
In `pv_inverter/packages/deye_hybrid_3p/remote.yaml` at line 68:

**Unsupported battery targets are accepted**

When a caller sets the remote battery voltage above the applicable battery limit, the 0–1000 V range permits writing unsupported targets to register 1107; 3P LV controls are bounded to 38–61 V and HV controls to 710 V, so the inverter cannot apply an out-of-range remote setpoint reliably.

Constrain the accepted maximum to the applicable LV or HV battery-voltage limit.

Also at `pv_inverter/deye_hybrid_3p_lv.yaml:40`.

Comment thread pv_inverter/packages/deye_hybrid_3p/remote.yaml
Comment thread pv_inverter/packages/deye_hybrid_3p/remote.yaml

This branch has not been deployed

No deployments