| select: | ||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: remote_mode | ||
| name: "Remote mode" | ||
| address: 1100 | ||
| value_type: U_WORD | ||
| optionsmap: | ||
| "Disable": 0 | ||
| "Enable remote mode 1": 1 | ||
| "Enable remote mode 2": 2 | ||
| "Enable remote mode 3": 3 | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: inverter_output_power_control_mode | ||
|
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. 🟡 Medium · Mode switches use stale setpoints When a client switches to per-phase control while changing its phase setpoints, or a Modbus write fails partway through those changes, Apply all setpoints first and switch the active control mode last, ideally through one coordinated update. Also at Prompt for AI agentsIn `pv_inverter/packages/deye_hybrid_3p/remote.yaml` at line 18:
**Mode switches use stale setpoints**
When a client switches to per-phase control while changing its phase setpoints, or a Modbus write fails partway through those changes, `inverter_output_power_control_mode` can enable per-phase control before the separate phase setpoint writes complete, so the inverter applies previously stored phase values in the meantime; a dropped write leaves the new mode using a mixed set of values. Update the setpoints before switching modes, or provide a grouped update that switches modes last.
Apply all setpoints first and switch the active control mode last, ideally through one coordinated update.
Also at `pv_inverter/packages/deye_hybrid_3p/remote.yaml:117-164`.
Author
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Yes, switching the control mode should be done such that the setpoints are written first and the mode change last. I'm not sure that's the job of this package. The question of a modbus write fail is interesting though, is there a way to block several register updates such that they all succeed or fail together? There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Not with the normal A custom ESPHome lambda/script can send one function-16 command containing the contiguous registers. This repository already uses that approach in
That prevents a failed setpoint write from activating the new mode, although it still cannot guarantee rollback if the inverter applies the write and the response is lost. Modbus defines request/reply transactions and function 16, but does not provide a general multi-request commit/rollback mechanism; whether a single function-16 write is internally atomic is device-specific. (Modbus Application Protocol Specification) For EMHASS, I would expose a single coordinated action/script for changing the mode and its setpoints, rather than relying on clients to update the independent entities in the correct order. |
||
| name: "Inverter output power control mode" | ||
| address: 1104 | ||
| value_type: U_WORD | ||
| optionsmap: | ||
| "Enable AC side control mode": 0 | ||
| "Enable battery side control mode": 1 | ||
| "Enable grid side control mode": 2 | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: battery_side_control | ||
| name: "Battery side control" | ||
| address: 1105 | ||
| value_type: U_WORD | ||
| optionsmap: | ||
| "Power": 2 | ||
| "SOC": 3 | ||
| "Voltage+Current": 4 | ||
| "Power+SOC": 5 | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: ac_power_control_mode | ||
| name: "AC power control mode" | ||
| address: 1106 | ||
| value_type: U_WORD | ||
| optionsmap: | ||
| "3 phase together": 0 | ||
| "Each phase independent": 1 | ||
|
|
||
| number: | ||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: remote_mode_watchdog_time | ||
| name: "Remote mode watchdog time" | ||
| min_value: 10 | ||
|
sourcery-ai[bot] marked this conversation as resolved.
|
||
| step: 1 | ||
| address: 1101 | ||
| value_type: U_WORD | ||
|
|
||
|
sourcery-ai[bot] marked this conversation as resolved.
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: battery_constant_voltage_mode | ||
| name: "Battery constant voltage mode" | ||
| min_value: 0 | ||
| max_value: 1000 | ||
|
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. 🟡 Medium · Unsupported battery targets are accepted When a caller sets the remote battery voltage above the applicable battery limit, the 0–1000 V range permits writing unsupported targets to register 1107; 3P LV controls are bounded to 38–61 V and HV controls to 710 V, so the inverter cannot apply an out-of-range remote setpoint reliably. Constrain the accepted maximum to the applicable LV or HV battery-voltage limit. Also at Prompt for AI agentsIn `pv_inverter/packages/deye_hybrid_3p/remote.yaml` at line 68:
**Unsupported battery targets are accepted**
When a caller sets the remote battery voltage above the applicable battery limit, the 0–1000 V range permits writing unsupported targets to register 1107; 3P LV controls are bounded to 38–61 V and HV controls to 710 V, so the inverter cannot apply an out-of-range remote setpoint reliably.
Constrain the accepted maximum to the applicable LV or HV battery-voltage limit.
Also at `pv_inverter/deye_hybrid_3p_lv.yaml:40`. |
||
| step: 0.1 | ||
| unit_of_measurement: "V" | ||
| multiply: 10 | ||
| address: 1107 | ||
| value_type: U_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: battery_constant_current_mode | ||
| name: "Battery constant current mode" | ||
| min_value: 0 | ||
| max_value: 200 | ||
| step: 0.1 | ||
| unit_of_measurement: "A" | ||
| multiply: 10 | ||
| address: 1108 | ||
| value_type: U_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: battery_constant_power_mode | ||
| name: "Battery constant power mode" | ||
| min_value: -120 | ||
| max_value: 120 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1109 | ||
| value_type: S_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: battery_constant_soc_mode | ||
| name: "Battery constant SOC mode" | ||
| min_value: 0 | ||
| max_value: 100 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1110 | ||
| value_type: U_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: inv_output_power_ABC | ||
| name: "Inverter output power phase ABC" | ||
| min_value: -120 | ||
| max_value: 120 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1111 | ||
| value_type: S_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: inv_output_power_A | ||
| name: "Inverter output power phase A" | ||
| min_value: -120 | ||
| max_value: 120 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1112 | ||
| value_type: S_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: inv_output_power_B | ||
| name: "Inverter output power phase B" | ||
| min_value: -120 | ||
| max_value: 120 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1113 | ||
| value_type: S_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: inv_output_power_C | ||
| name: "Inverter output power phase C" | ||
| min_value: -120 | ||
| max_value: 120 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1114 | ||
| value_type: S_WORD | ||
|
|
||
| - platform: modbus_controller | ||
| use_write_multiple: true | ||
| modbus_controller_id: ${modbus_controller_id} | ||
| id: remote_mode_max_solar_power | ||
| name: "Remote Mode max solar power" | ||
| min_value: 0 | ||
| max_value: 200 | ||
| step: 0.1 | ||
| unit_of_measurement: "%" | ||
| multiply: 10 | ||
| address: 1115 | ||
| value_type: U_WORD | ||