fix: detect the Minimed Flex pump (#91) - #93

Merged
NovaLux12 merged 1 commit into
mainfrom
fix/flex-detection-91
Oct 9, 2026
Merged

NovaLux12 merged 1 commit into
mainfrom
fix/flex-detection-91

Conversation

@NovaLux12

Copy link
Copy Markdown
Owner

Summary

The Minimed Flex pump (MMT-8062/8063/8082/8083/8084/8085) is already shipping and reported live upstream (domien-f#3, where a minimal version of this fix is also proposed as upstream PR #5): silent zero-data fetch after a 780G-to-Flex upgrade.

Neither the Flex family string nor its models match anything the bridge recognises, so isBleDevice() returns false and the account falls back to monitor/data, which returns {} for BLE-era devices.

Closes #91.

  • Six Flex model prefixes, labelled INFERRED from Medtronic's portal bundle (same labelling as the Guardian 4 / Simplera system rows).
  • The FLEX family token as a deliberate substring test — unlike BLE, which is prefix-only because it is a substring of ordinary words. Audited: FLEX is not a substring of any other known family value (GUARDIAN, NGP, CGM, CC, PARADIGM, BLE_*, SIMPLERA*); the reasoning is recorded next to the code.
  • Call-site test proving a family-only Flex payload (no model — the hardest case) takes the BLE endpoint exactly once and never touches connect/data.

Verification

npx vitest run            → 246 passing / 22 files (baseline 242)
npx tsc --noEmit          → clean

Revert-verified: removing the six rows fails the model test; removing the FLEX token fails both the family test and the call-site test (which then resolves the monitor payload instead of the BLE payload — the exact upstream symptom). Both spellings INFERRED, unverified on the wire.

The Flex (MMT-8062/8063/8082-8085, "Minimed Flex") is already shipping and
reported live upstream (domien-f#3): silent zero-data fetch
after a 780G-to-Flex upgrade. Neither its family string nor its models match
anything in BLE_DEVICE_MODELS, so isBleDevice() returns false and the bridge
falls back to monitor/data, which returns {} for BLE devices.

- Six Flex model prefixes, labelled INFERRED from the vendor bundle.
- The FLEX family token as a deliberate substring test (unlike BLE, which is
  prefix-only): audited that FLEX is not a substring of any other known family
  value, with the reasoning recorded next to the code.
- Call-site test proving a family-only Flex payload takes the BLE endpoint
  and never touches connect/data (verified to fail with the token removed).

Tests: 246 passing (baseline 242). tsc --noEmit clean.
@NovaLux12
NovaLux12 force-pushed the fix/flex-detection-91 branch from 8fde156 to c93ac46 Compare October 9, 2026 12:42
@NovaLux12
NovaLux12 merged commit 79d6e5c into main Oct 9, 2026
2 checks passed
@NovaLux12
NovaLux12 deleted the fix/flex-detection-91 branch October 9, 2026 12:48
NovaLux12 added a commit that referenced this pull request Oct 9, 2026
Medtronic publishes the complete device-family vocabulary, unauthenticated,
at GET /patient/v2/configuration/public — the same host the bridge already
talks to. #93 added the six Minimed Flex model prefixes and, alongside
them, guessed the family token as a FLEX substring match.

The published document settles it.
personal.device.family.to.model.mapping lists sixteen families, and
system.settings.transfer.feature.config.device.mapping independently maps
"CC880" to the display name "MiniMed™ Flex". So CC880 is the Flex family,
and the six models #93 added do appear under it.

isBleDevice() now matches the exact published token CC880, so a family-only
payload is detected without relying on deviceModel being present. Before
this, isBleDevice('CC880', undefined) returned false — reproducing #91's
silent zero-data fetch, the failure mode a Flex user actually hits, since
monitor/data returns deviceFamily while medicalDeviceFamily is undefined
on the patient path and models are not guaranteed.

The FLEX substring match is kept as a fallback for the display-name
spelling the vendor also publishes ("Minimed™ Flex"), on the same
reasoning that SIMPLERA_SYSTEM may arrive as "Simplera™ system". Audited
against all sixteen published families: none contains FLEX, so no real
device is misrouted today, and CC880 detection never depended on it since
that token has no FLEX in it. The residual looseness — a substring match
also accepts nonsense like "REFLEX" — is documented rather than eliminated
and is deliberately not pinned as a contract, so a later contributor can
tighten the matcher without rewriting an assertion that enshrined it.

New test classifies the entire published vocabulary: all sixteen families,
each with its expected verdict and a stated reason. CC840, EAGLE, GST,
NMX7, NMX8, GM and INSTINCT are deliberately left unmatched — nothing
confirms they are BLE-paired, and routing a non-BLE device down the BLE
endpoint is its own silent failure. The table means a family Medtronic adds
later is a decision someone makes rather than a gap that surfaces weeks
later as "the bridge uploaded nothing". Its completeness check is a
self-consistency guard, not a vendor-change detector, and is labelled as
such.

Caveat: this is Medtronic's published configuration, not an observation of
a monitor/data response. It establishes the vocabulary, not which field
carries it or in what casing. #81 stays open until a token confirms.

Tests: 323 passing (baseline 298). npm run typecheck clean.
NovaLux12 added a commit that referenced this pull request Oct 9, 2026
Medtronic publishes the complete device-family vocabulary, unauthenticated,
at GET /patient/v2/configuration/public — the same host the bridge already
talks to. #93 added the six Minimed Flex model prefixes and, alongside
them, guessed the family token as a FLEX substring match.

The published document settles it.
personal.device.family.to.model.mapping lists sixteen families, and
system.settings.transfer.feature.config.device.mapping independently maps
"CC880" to the display name "MiniMed™ Flex". So CC880 is the Flex family,
and the six models #93 added do appear under it.

isBleDevice() now matches the exact published token CC880, so a family-only
payload is detected without relying on deviceModel being present. Before
this, isBleDevice('CC880', undefined) returned false — reproducing #91's
silent zero-data fetch, the failure mode a Flex user actually hits, since
monitor/data returns deviceFamily while medicalDeviceFamily is undefined
on the patient path and models are not guaranteed.

The FLEX substring match is kept as a fallback for the display-name
spelling the vendor also publishes ("Minimed™ Flex"), on the same
reasoning that SIMPLERA_SYSTEM may arrive as "Simplera™ system". Audited
against all sixteen published families: none contains FLEX, so no real
device is misrouted today, and CC880 detection never depended on it since
that token has no FLEX in it. The residual looseness — a substring match
also accepts nonsense like "REFLEX" — is documented rather than eliminated
and is deliberately not pinned as a contract, so a later contributor can
tighten the matcher without rewriting an assertion that enshrined it.

New test classifies the entire published vocabulary: all sixteen families,
each with its expected verdict and a stated reason. CC840, EAGLE, GST,
NMX7, NMX8, GM and INSTINCT are deliberately left unmatched — nothing
confirms they are BLE-paired, and routing a non-BLE device down the BLE
endpoint is its own silent failure. The table means a family Medtronic adds
later is a decision someone makes rather than a gap that surfaces weeks
later as "the bridge uploaded nothing". Its completeness check is a
self-consistency guard, not a vendor-change detector, and is labelled as
such.

Caveat: this is Medtronic's published configuration, not an observation of
a monitor/data response. It establishes the vocabulary, not which field
carries it or in what casing. #81 stays open until a token confirms.

Tests: 323 passing (baseline 298). npm run typecheck clean.