Entity mapping (M0 discovery, read-only)

Discovered 7 October 2026 via the HA REST/WebSocket API (HA 2026.9.3, Europe/London). 1,628 entities. Nothing was written.

Status legend: V verified from live state/attributes · ? needs confirmation · ✗ unusable.

Daikin — P1P2MQTT (bridge0)

Telemetry

Role Entity Unit / class Status / notes
Room temperature (Daikin RT sensor) sensor.bridge0_sensors_temperature_room °C, measurement V. Identical to _room_wall; this is the thermostat in the north-facing living room
Outdoor temperature sensor.bridge0_sensors_temperature_outside °C, measurement V (_outside_unit also available)
Leaving water sensor.bridge0_sensors_temperature_r1t_hp2gas_water °C, measurement V. Use R1T: r2t_leaving_water permanently reads −128 °C (✗)
Return water sensor.bridge0_sensors_temperature_r4t_return_water °C, measurement V
Flow sensor.bridge0_sensors_flow L/min, measurement V
Requested LWT sensor.bridge0_lwt_lwt_setpoint °C V. Clamped at 25 °C minimum (field setting 9-01)
Current heating deviation sensor.bridge0_lwt_deviation_heating °C V
Room heating setpoint sensor.bridge0_room_room_heating_setpoint °C V
Compressor on binary_sensor.bridge0_mode_compressor – V (no long-term statistics: binary)
Thermostat heating demand binary_sensor.bridge0_mode_valve_zone_main – V (test 7 Oct 2026): on 0 s after the setpoint exceeded room temperature, pump +10 s, compressor +4 min; off with demand
Space heating enabled switch.bridge0_mode_altherma_on; binary_sensor.bridge0_unknown_climate_active_q4 follows it – V: q4 is not demand
3-way valve binary_sensor.bridge0_dhw_valve_dhw_tank – V: on = tank position (rest position), off = radiators
Compressor frequency sensor.bridge0_mode_compressor_rpm Hz, measurement V. Usable for run/partial-hour detection in LTS
Defrost binary_sensor.bridge0_mode_defrost_active – V (no LTS)
DHW running binary_sensor.bridge0_dhw_dhw_demand – V: on exactly during DHW runs (e.g. 03:52–04:15 daily, matches compressor). _dhw_dhw = DHW function enabled (always on), _dhw_valve_dhw_tank always on, _dhw_dhw_related_q always off — not usable
Electrical power sensor.bridge0_power_consumption_heatpump W V (includes pump/controls, ?)
Thermal power sensor.bridge0_power_production_heatpump W V. Equals flow·cp·ΔT (bridge-calculated, not independent)
Backup heater power sensor.bridge0_power_consumption_buh W V. Zero all winter
Heating elec/heat counters sensor.bridge0_meters_electricity_consumed_compressor_heating, …energy_produced_compressor_heating kWh, total_increasing V. 1 kWh resolution; LTS start 2025-10-19
DHW elec/heat counters …consumed_compressor_dhw, …produced_compressor_dhw kWh V
Backup heater counters …consumed_backup_heating, …consumed_backup_dhw kWh V
Compressor hours sensor.bridge0_meters_hours_compressor_heating / _dhw h V
Compressor starts sensor.bridge0_meters_starts_compressor – V, but no state_class → no LTS
Faults sensor.bridge0_mode_errorcode1/2, _errorsubcode; Onecta binary_sensor.altherma_*_is_in_error_state_2 – ? need "no error" value
Write budget number.bridge0_bridge_write_budget (100), number.bridge0_bridge_write_budget_period (60), sensor.bridge0_bridge_writes_refused_budget, sensor.bridge0_bridge_writes_refused_busy, sensor.bridge0_bridge_error_budget – V present; budget/period semantics ?

Writable candidates (none to be used before M4)

Function Entity Bounds Notes
LWT heating deviation climate.bridge0_lwt_abs_heating (friendly name "LWT Deviation_Heating") −10…+10, step 1 Primary actuator in v1 plan. current_temperature reports −128 (ignore)
Room heating setpoint climate.bridge0_room_room_heating 16…26, step 0.5 Relevant because the unit runs in RT mode (see below)
DHW setpoint climate.bridge0_dhw_dhw_setpoint 30…60, step 1 M6 only
DHW boost switch.bridge0_dhw_dhw_boost – M6 only, semantics ?
Must never be touched button.bridge0_mode_daikin_defrost_request, button.bridge0_fieldsettings_daikin_restart_careful, field-setting numbers/selects, number.bridge0_bridge_write_budget, switch.bridge0_mode_altherma_on – Safety-excluded

Relevant native configuration (read from field settings)

Setting Value Implication
Control mode (select.bridge0_fieldsettings_rt_lwt, C-07) RT (Daikin room-thermostat control) Daikin uses its own room sensor to switch heating and modulate LWT
RT modulation (select.bridge0_fieldsettings_rt_modulation, 8-05) Modulation, max 5 K (8-06) Daikin already adds up to ±5 K room feedback on top of the WD curve
Setpoint mode (select.bridge0_mode_program_wd_abs) WD+prog Weather-dependent with schedule
Preset (select.bridge0_mode_preset_mode) Schedule; comfort 21.0, eco 19.0 Room setpoint schedule
Room temperature hysteresis (9-0C) 1.0 K
Overshoot 2
Heating LWT range (9-01 / 9-00) 25 … 47 °C 25 °C is also the plant's minimum achievable LWT (confirmed); clamps the requested LWT for To ≥ ~9 °C
DHW reheat (6-0D), disinfection (2-00…2-04) reheat 2; disinfection day 2, start 3, 55 °C, 45 min M6, must be preserved
DHW priority (C-00) 1
Quiet mode Auto
WD curve raw values (0-00…1-03) decoded values look implausible (e.g. 1, 25) ? verify decoding against the HCI/Madoka menu

Daikin — Onecta cloud integration (altherma_*_2)

Second, cloud-based path to the same unit: climate.altherma_leaving_water_offset_2, climate.altherma_room_temperature_2, water_heater.altherma_2, schedules select.altherma_climatecontrol_schedule_2 (User defined 1) and select.altherma_domestichotwatertank_schedule_2. Reports control_mode = roomTemperature, setpoint_mode = weatherDependent, rate limit 200/day.

Risk: two independent writers to the same unit. The MPC command gateway must be the only automated writer; Onecta schedules may change setpoints underneath it and must be treated as "native schedule" input.

Predbat (add-on, v9.2.0)

  • Mode select.predbat_mode = Control charge & discharge; switch.predbat_predheat_enable = on; sensor.predbat_load_ml_forecast = active.
  • Economics: sensor.predbat_marginal_energy_costs (p), binary_sensor.predbat_low_rate_slot, binary_sensor.predbat_marginal_rate_now_*, PV forecast sensor.predbat_pv_*, SOC max sensor.predbat_soc_max_calculated (26.2 kWh), reserve input_number.predbat_set_reserve_min (21 %).
  • Tariff windows set by automations automation.set_off_peak_rate / automation.set_peak_tariff (off-peak ≈ 00:00–05:00 local).
  • ? Remaining 118 predbat.* entities (plan, rates, SOC forecast attributes) to map in M1.

Predheat (inside Predbat)

predheat.heat_energy (kWh, attribute external: list of {last_updated, energy} at 10-min steps, cumulative), predheat.internal_temp (+_h1/_h2/_h8, attribute results), predheat.target_temp 21.0, predheat.volume_temp, predheat.cost*. Configuration lives in apps.yaml, not visible through the API.

Weather

weather.forecast_home (Met.no) and weather.openweathermap. Forecast via weather.get_forecasts.

Existing automations touching heating

automation.heating_switch_on/off (input_boolean.heating_switch; last used June 2025). No automation writes the LWT deviation. The overnight −6 K deviation seen in the history (below) therefore comes from a native or Onecta schedule. ?