Predheat replay and calibration (M1)

Generated 2026-10-07 by tools/predheat_replay.py. Window 2025-11-01 … 2026-03-31, 150 complete days (74 train / 76 test, split by ISO-week parity). Outdoor sensor to_ecowitt, measured (perfect forecast). Mean measured heating electricity on test days: 5.14 kWh/day.

Hold-out error

Set Elec MAE kWh/day Elec bias kWh/day Room RMSE K (hourly) Room MAE @6 h K Room MAE @24 h K
current 0.98 +0.40 1.90 0.65 2.56
fitted 0.84 -0.11 1.16 0.82 1.16
calibrated 0.92 +0.49 0.75 0.32 0.79

Parameters

Parameter current fitted calibrated
heat_loss_watts 156 94 94
heat_loss_degrees 0.0194 0.0315 0.02
heat_gain_static 400 440 440
heat_min_power 500 680 1500
flow_difference_target 5 5 1
heat_cop 3.68 3.81 3.81
hysteresis 1 1 1.5
hysteresis_off 1 1 0.1091
implied C (kWh/K) 8.0 3.0 4.7

Calibrated parameters at a search bound (structural mismatch, treat with caution): heat_loss_degrees, heat_min_power, flow_difference_target, hysteresis.

Recommended predheat: values (fitted set: lowest hold-out electricity error)

    heat_loss_watts: 94
    heat_loss_degrees: 0.0315
    heat_gain_static: 440
    heat_min_power: 680
    flow_difference_target: 5.0
    heat_cop: 3.81
    hysteresis: 1.00
    hysteresis_off: 1.00
    heat_pump_efficiency:
      -20: 1.93
      -18: 1.97
      -16: 2.02
      -14: 2.07
      -12: 2.11
      -10: 2.2
      -8: 2.3
      -6: 2.39
      -4: 2.48
      -2: 2.57
      0: 2.66
      2: 2.83
      4: 2.97
      6: 3.14
      8: 3.28
      10: 3.28
      12: 3.63
      14: 3.81
      16: 3.81
      18: 3.81
      20: 3.81

Limitations: Predheat does not model the Daikin's RT modulation, the overnight deviation schedule or DHW interruptions; the daily counters have 1 kWh resolution; hourly room temperatures are means.