| 1 | +# Canonical energy sensors — PHASE A (new sensors only; nothing existing is changed) |
| 2 | +# Plan and rationale: docs/energy_sensors_plan.md |
| 3 | +# |
| 4 | +# Install: |
| 5 | +# 1. configuration.yaml: homeassistant: |
| 6 | +# packages: !include_dir_named packages |
| 7 | +# 2. copy this file to /config/packages/energy.yaml |
| 8 | +# 3. Developer tools → YAML → Check configuration, then restart Home Assistant. |
| 9 | +# |
| 10 | +# Sign conventions: grid + = import; Solis AC + = inverter delivering to the house (− = charging from |
| 11 | +# the grid); battery + = discharging; generation and loads ≥ 0. |
| 12 | +# |
| 13 | +# The four sensors ending in "_new" are the replacements for the faulty helpers solis_power, |
| 14 | +# pv_power, house_power and total_house_consumption. Phase B (after 3–7 days of comparison) gives |
| 15 | +# them the old entity IDs; until then the old helpers stay untouched. |
| 16 | + |
| 17 | +template: |
| 18 | + - sensor: |
| 19 | + # --- power (W) --------------------------------------------------------------------------- |
| 20 | + - name: "Grid power" |
| 21 | + unique_id: energy_grid_power_new |
| 22 | + default_entity_id: sensor.solis_power_new |
| 23 | + unit_of_measurement: W |
| 24 | + device_class: power |
| 25 | + state_class: measurement |
| 26 | + # Glow/Hildebrand smart meter; Solis CT (≈ −0.94 × smart meter + 53 W) only as fallback. |
| 27 | + state: > |
| 28 | + {% set sm = states('sensor.smart_meter_electricity_power') %} |
| 29 | + {% if is_number(sm) %}{{ sm | float | round(0) }} |
| 30 | + {% else %}{{ ((53 - states('sensor.solis_meter_active_power') | float) / 0.94) | round(0) }} |
| 31 | + {% endif %} |
| 32 | + availability: > |
| 33 | + {{ is_number(states('sensor.smart_meter_electricity_power')) |
| 34 | + or is_number(states('sensor.solis_meter_active_power')) }} |
| 35 | +
|
| 36 | + - name: "PV power" |
| 37 | + unique_id: energy_pv_power_new |
| 38 | + default_entity_id: sensor.pv_power_new |
| 39 | + unit_of_measurement: W |
| 40 | + device_class: power |
| 41 | + state_class: measurement |
| 42 | + # Solis PV (DC, garage) + roof GW2000 (HomeWizard meter, export negative) + shed micro-inverter |
| 43 | + state: > |
| 44 | + {{ (states('sensor.solis_pv_total_power') | float(0) |
| 45 | + + [0, -(states('sensor.kwh_meter_power_2') | float(0))] | max |
| 46 | + + states('sensor.shed_power_ac') | float(0)) | round(0) }} |
| 47 | + availability: > |
| 48 | + {{ is_number(states('sensor.solis_pv_total_power')) |
| 49 | + and is_number(states('sensor.kwh_meter_power_2')) }} |
| 50 | +
|
| 51 | + - name: "House power" |
| 52 | + unique_id: energy_house_power_new |
| 53 | + default_entity_id: sensor.house_power_new |
| 54 | + unit_of_measurement: W |
| 55 | + device_class: power |
| 56 | + state_class: measurement |
| 57 | + # AC side: grid + Solis AC output + roof (net, incl. its standby) + shed. |
| 58 | + # Excludes the Solis conversion/standby losses (see solis_loss_power). |
| 59 | + state: > |
| 60 | + {% set grid = states('sensor.solis_power_new') | float(0) %} |
| 61 | + {% set solis = states('sensor.solis_active_power') | float(0) %} |
| 62 | + {% set roof = -(states('sensor.kwh_meter_power_2') | float(0)) %} |
| 63 | + {% set shed = states('sensor.shed_power_ac') | float(0) %} |
| 64 | + {{ [grid + solis + roof + shed, 0] | max | round(0) }} |
| 65 | + availability: > |
| 66 | + {{ has_value('sensor.solis_power_new') |
| 67 | + and is_number(states('sensor.solis_active_power')) |
| 68 | + and is_number(states('sensor.kwh_meter_power_2')) }} |
| 69 | +
|
| 70 | + - name: "Solis loss power" |
| 71 | + unique_id: energy_solis_loss_power |
| 72 | + default_entity_id: sensor.solis_loss_power |
| 73 | + unit_of_measurement: W |
| 74 | + device_class: power |
| 75 | + state_class: measurement |
| 76 | + # Conversion + standby losses of the Solis (inside the house): PV + battery − AC output. |
| 77 | + state: > |
| 78 | + {{ [states('sensor.solis_pv_total_power') | float(0) |
| 79 | + + states('sensor.battery_power') | float(0) |
| 80 | + - states('sensor.solis_active_power') | float(0), 0] | max | round(0) }} |
| 81 | + availability: > |
| 82 | + {{ is_number(states('sensor.solis_pv_total_power')) |
| 83 | + and is_number(states('sensor.battery_power')) |
| 84 | + and is_number(states('sensor.solis_active_power')) }} |
| 85 | +
|
| 86 | + - name: "Heat pump power" |
| 87 | + unique_id: energy_heat_pump_power |
| 88 | + default_entity_id: sensor.heat_pump_power |
| 89 | + unit_of_measurement: W |
| 90 | + device_class: power |
| 91 | + state_class: measurement |
| 92 | + state: "{{ [states('sensor.kwh_meter_power') | float(0), 0] | max | round(0) }}" |
| 93 | + availability: "{{ is_number(states('sensor.kwh_meter_power')) }}" |
| 94 | + |
| 95 | + # Split of the metered heat-pump power. The 3-way valve rests on "tank" when idle, so the |
| 96 | + # DHW demand signal is used (4–10 Oct 2026: 6.8 kWh DHW, 2.3 kWh standby, heating ≈ 0). |
| 97 | + - name: "Heat pump DHW power" |
| 98 | + unique_id: energy_heat_pump_dhw_power |
| 99 | + default_entity_id: sensor.heat_pump_dhw_power |
| 100 | + unit_of_measurement: W |
| 101 | + device_class: power |
| 102 | + state_class: measurement |
| 103 | + state: > |
| 104 | + {{ states('sensor.heat_pump_power') | float(0) |
| 105 | + if is_state('binary_sensor.bridge0_dhw_dhw_demand', 'on') else 0 }} |
| 106 | + availability: > |
| 107 | + {{ has_value('sensor.heat_pump_power') |
| 108 | + and has_value('binary_sensor.bridge0_dhw_dhw_demand') }} |
| 109 | +
|
| 110 | + - name: "Heat pump heating power" |
| 111 | + unique_id: energy_heat_pump_heating_power |
| 112 | + default_entity_id: sensor.heat_pump_heating_power |
| 113 | + unit_of_measurement: W |
| 114 | + device_class: power |
| 115 | + state_class: measurement |
| 116 | + # space heating: compressor or circulation pump running without DHW demand (incl. defrost) |
| 117 | + state: > |
| 118 | + {% set running = is_state('binary_sensor.bridge0_mode_compressor', 'on') |
| 119 | + or is_state('binary_sensor.bridge0_mode_circulation_pump', 'on') %} |
| 120 | + {{ states('sensor.heat_pump_power') | float(0) |
| 121 | + if running and not is_state('binary_sensor.bridge0_dhw_dhw_demand', 'on') else 0 }} |
| 122 | + availability: > |
| 123 | + {{ has_value('sensor.heat_pump_power') |
| 124 | + and has_value('binary_sensor.bridge0_dhw_dhw_demand') |
| 125 | + and has_value('binary_sensor.bridge0_mode_compressor') |
| 126 | + and has_value('binary_sensor.bridge0_mode_circulation_pump') }} |
| 127 | +
|
| 128 | + - name: "Heat pump standby power" |
| 129 | + unique_id: energy_heat_pump_standby_power |
| 130 | + default_entity_id: sensor.heat_pump_standby_power |
| 131 | + unit_of_measurement: W |
| 132 | + device_class: power |
| 133 | + state_class: measurement |
| 134 | + state: > |
| 135 | + {{ [states('sensor.heat_pump_power') | float(0) |
| 136 | + - states('sensor.heat_pump_dhw_power') | float(0) |
| 137 | + - states('sensor.heat_pump_heating_power') | float(0), 0] | max }} |
| 138 | + availability: > |
| 139 | + {{ has_value('sensor.heat_pump_dhw_power') and has_value('sensor.heat_pump_heating_power') }} |
| 140 | +
|
| 141 | + - name: "House power excl. heating" |
| 142 | + unique_id: energy_house_power_excl_heating |
| 143 | + default_entity_id: sensor.house_power_excl_heating |
| 144 | + unit_of_measurement: W |
| 145 | + device_class: power |
| 146 | + state_class: measurement |
| 147 | + # household load for Predbat/Predheat: space heating removed, DHW and standby kept |
| 148 | + state: > |
| 149 | + {{ [states('sensor.house_power_new') | float(0) |
| 150 | + - states('sensor.heat_pump_heating_power') | float(0), 0] | max }} |
| 151 | + availability: > |
| 152 | + {{ has_value('sensor.house_power_new') and has_value('sensor.heat_pump_heating_power') }} |
| 153 | +
|
| 154 | + - name: "House power excl. heat pump" |
| 155 | + unique_id: energy_house_power_excl_heat_pump |
| 156 | + default_entity_id: sensor.house_power_excl_heat_pump |
| 157 | + unit_of_measurement: W |
| 158 | + device_class: power |
| 159 | + state_class: measurement |
| 160 | + state: > |
| 161 | + {{ [states('sensor.house_power_new') | float(0) |
| 162 | + - states('sensor.heat_pump_power') | float(0), 0] | max }} |
| 163 | + availability: > |
| 164 | + {{ has_value('sensor.house_power_new') and has_value('sensor.heat_pump_power') }} |
| 165 | +
|
| 166 | +# --- energy (kWh): integrals of the power sensors --------------------------------------------- |
| 167 | +sensor: |
| 168 | + - platform: integration |
| 169 | + source: sensor.house_power_new |
| 170 | + name: House energy total |
| 171 | + unique_id: energy_house_energy_total |
| 172 | + method: left |
| 173 | + round: 3 |
| 174 | + unit_prefix: k |
| 175 | + unit_time: h |
| 176 | + max_sub_interval: |
| 177 | + minutes: 1 |
| 178 | + - platform: integration |
| 179 | + source: sensor.house_power_excl_heating |
| 180 | + name: House energy excl heating total |
| 181 | + unique_id: energy_house_energy_excl_heating_total |
| 182 | + method: left |
| 183 | + round: 3 |
| 184 | + unit_prefix: k |
| 185 | + unit_time: h |
| 186 | + max_sub_interval: |
| 187 | + minutes: 1 |
| 188 | + - platform: integration |
| 189 | + source: sensor.solis_loss_power |
| 190 | + name: Solis loss energy total |
| 191 | + unique_id: energy_solis_loss_energy_total |
| 192 | + method: left |
| 193 | + round: 3 |
| 194 | + unit_prefix: k |
| 195 | + unit_time: h |
| 196 | + max_sub_interval: |
| 197 | + minutes: 1 |
| 198 | + - platform: integration |
| 199 | + source: sensor.heat_pump_dhw_power |
| 200 | + name: Heat pump DHW energy total |
| 201 | + unique_id: energy_heat_pump_dhw_energy_total |
| 202 | + method: left |
| 203 | + round: 3 |
| 204 | + unit_prefix: k |
| 205 | + unit_time: h |
| 206 | + max_sub_interval: |
| 207 | + minutes: 1 |
| 208 | + - platform: integration |
| 209 | + source: sensor.heat_pump_heating_power |
| 210 | + name: Heat pump heating energy total |
| 211 | + unique_id: energy_heat_pump_heating_energy_total |
| 212 | + method: left |
| 213 | + round: 3 |
| 214 | + unit_prefix: k |
| 215 | + unit_time: h |
| 216 | + max_sub_interval: |
| 217 | + minutes: 1 |
| 218 | + - platform: integration |
| 219 | + source: sensor.heat_pump_standby_power |
| 220 | + name: Heat pump standby energy total |
| 221 | + unique_id: energy_heat_pump_standby_energy_total |
| 222 | + method: left |
| 223 | + round: 3 |
| 224 | + unit_prefix: k |
| 225 | + unit_time: h |
| 226 | + max_sub_interval: |
| 227 | + minutes: 1 |
| 228 | + |
| 229 | +# --- daily / periodic counters ------------------------------------------------------------------ |
| 230 | +utility_meter: |
| 231 | + total_house_consumption_new: |
| 232 | + unique_id: energy_total_house_consumption_new |
| 233 | + source: sensor.house_energy_total |
| 234 | + cycle: daily |
| 235 | + house_load_excl_heating_daily: |
| 236 | + unique_id: energy_house_load_excl_heating_daily |
| 237 | + source: sensor.house_energy_excl_heating_total |
| 238 | + cycle: daily |
| 239 | + solis_loss_energy_daily: |
| 240 | + unique_id: energy_solis_loss_energy_daily |
| 241 | + source: sensor.solis_loss_energy_total |
| 242 | + cycle: daily |
| 243 | + # Replacements for the broken YAML templates ashp_{heating,dhw}_power_consumption_* (phase B |
| 244 | + # renames these keys to the ashp_* names after the old templates are removed). |
| 245 | + heat_pump_dhw_energy_daily: |
| 246 | + unique_id: energy_heat_pump_dhw_energy_daily |
| 247 | + source: sensor.heat_pump_dhw_energy_total |
| 248 | + cycle: daily |
| 249 | + heat_pump_dhw_energy_weekly: |
| 250 | + unique_id: energy_heat_pump_dhw_energy_weekly |
| 251 | + source: sensor.heat_pump_dhw_energy_total |
| 252 | + cycle: weekly |
| 253 | + heat_pump_dhw_energy_monthly: |
| 254 | + unique_id: energy_heat_pump_dhw_energy_monthly |
| 255 | + source: sensor.heat_pump_dhw_energy_total |
| 256 | + cycle: monthly |
| 257 | + heat_pump_dhw_energy_annually: |
| 258 | + unique_id: energy_heat_pump_dhw_energy_annually |
| 259 | + source: sensor.heat_pump_dhw_energy_total |
| 260 | + cycle: yearly |
| 261 | + heat_pump_heating_energy_daily: |
| 262 | + unique_id: energy_heat_pump_heating_energy_daily |
| 263 | + source: sensor.heat_pump_heating_energy_total |
| 264 | + cycle: daily |
| 265 | + heat_pump_heating_energy_weekly: |
| 266 | + unique_id: energy_heat_pump_heating_energy_weekly |
| 267 | + source: sensor.heat_pump_heating_energy_total |
| 268 | + cycle: weekly |
| 269 | + heat_pump_heating_energy_monthly: |
| 270 | + unique_id: energy_heat_pump_heating_energy_monthly |
| 271 | + source: sensor.heat_pump_heating_energy_total |
| 272 | + cycle: monthly |
| 273 | + heat_pump_heating_energy_annually: |
| 274 | + unique_id: energy_heat_pump_heating_energy_annually |
| 275 | + source: sensor.heat_pump_heating_energy_total |
| 276 | + cycle: yearly |
| 277 | + heat_pump_standby_energy_daily: |
| 278 | + unique_id: energy_heat_pump_standby_energy_daily |
| 279 | + source: sensor.heat_pump_standby_energy_total |
| 280 | + cycle: daily |
0 commit comments