validation: Delta Flume riser VIV in a stepped current (L3-D) (#167)
Validation case L3-D: cross-flow and in-line VIV of the Delta Flume riser (Chaplin et al. 2005a, 2005b) in the nine blind-trial stepped currents, U 0.16-0.95 m/s over the lower 5.94 m of a 13.12 m pinned riser with the top spring in series. The VIV set is the synchronisation model with nothing fitted to these data: Cl 0.8 in f0 0.18 +/- 0.08, in-line Cx 0.85 and alpha 0.15, CD 1.2 and Chaplin's in-line drag amplification. Measurements are the experimenters' processed results from the blind-trial presentation, read from the vector graphics through the tick labels. Dominant mode right in 5 of 9 cases and within one in all; mean in-line displacement within 17 % in 7 of 9; CF amplitude -44 % to +4 % of the summary maxima. dt/2 and 128 elements move the std and mean metrics by at most 2.6 % except the beating case 5 and the two-response case 9, both documented. The mode projection uses a row-wise trapezoid so NumPy 1.x runs it. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
1 parent 5114299 commit 6c469fe

22 files changed

Lines changed: 2177 additions & 4 deletions

‎CHANGELOG.md‎

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -103,6 +103,11 @@ All notable changes to CableDyn are recorded in this file. The format follows
103103
Thorsen et al. (2017) use for it: dominant strain frequency 0.992 Hz against the measured
104104
1.00 Hz, largest r.m.s. strain 7.3 % above the measured largest, station mean 3.6 % above;
105105
converged in mesh and time step to 0.2 %.
106+
- Validation case L3-D (`validation/experiments/delta_flume`): cross-flow and in-line VIV of the
107+
Delta Flume riser in the nine blind-trial stepped-current cases of Chaplin et al. (2005b), with
108+
one generic coefficient set and the drag amplification on the in-line drag alone, against the
109+
experimenters' measured envelopes and summaries: dominant mode right in 5 of 9 and within one in
110+
all, mean in-line displacement within 17 % in 7 of 9, cross-flow amplitude −44 % to +4 %.
106111
- Theory manual, Published coefficient sets: the VIV coefficient sets of Thorsen et al. (2016,
107112
2017), Ulveseter et al. (2018), Andersen et al. (2024a, b) and Facchinetti et al. (2004), each
108113
with its source, its test data and the line-type columns it maps to, and Thorsen et al.'s

‎VALIDATION.md‎

Lines changed: 19 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -82,6 +82,7 @@ article's methods, are compared in
8282
| **L3-H** | Holcombe static lazy-wave experiment | measured marker geometry | position RMSE 1.07–1.89% of suspended length; peak marker-curvature error 0.34–5.54% | end-restraint bracket | Pass |
8383
| **L3-B** | Bergdahl chain experiment, 30 orbit conditions | measured upper-end force | RMSE 1.58 N; MAPE 3.11%; Pearson 0.993; Lin concordance 0.989 | full published matrix | Pass |
8484
| **L3-C** | Chaplin Delta Flume riser, still-water natural frequencies | measured modes 1–7 at five tensions | mean error +1.87%, mean absolute 2.28%, largest 4.88% (34 of 35; one outlier reported) | full published table, no fitted parameter | Pass |
85+
| **L3-D** | Chaplin Delta Flume riser in a stepped current, blind-trial cases 1–9, cross-flow and in-line VIV | measured dominant mode, peak cross-flow amplitude, mean in-line displacement, curvature standard deviations | mode right in 5/9, within one in 9/9; mean in-line within ±17% in 7/9 (−25% to +34%); cross-flow amplitude −44% to +4%; cross-flow curvature −39% to +26% | generic coefficient set, no fitted parameter | Pass measured |
8586
| **L3-W** | SJTU steel catenary riser in 0.2 m/s current, cross-flow VIV | measured r.m.s. strain (25 stations) and dominant frequency | frequency 0.992 vs 1.00 Hz; max r.m.s. strain +7.3%, station mean +3.6% | published coefficient set, no fitted parameter | Pass |
8687
| **L-fig** | Along-arc curvature overlay (CableDyn / OrcaFlex / MoorDyn-F ±4×) | 3-code committed record | CableDyn peak 0.11% from OrcaFlex | <0.5% | Pass |
8788
| **L4-1** | Coupled platform + mooring | synthetic reference | bit-for-bit | — | Pass |
@@ -339,6 +340,24 @@ scripts, results, and source provenance are in
339340
separately. 128 elements and ten times the unpublished axial stiffness change no frequency by
340341
more than 3e-6 and 1.2e-4.
341342

343+
- **L3-D Delta Flume riser, VIV in a stepped current**
344+
([Chaplin et al., 2005a](https://cabledyn.readthedocs.io/en/latest/references.html#ref-chaplin2005);
345+
[Chaplin et al., 2005b](https://cabledyn.readthedocs.io/en/latest/references.html#ref-chaplin2005b)):
346+
the nine blind-trial cases, the lower 5.94 m of the L3-C riser in 0.16–0.95 m/s, with the top
347+
spring in series and the measured mean top tension set statically. One generic set for all
348+
cases: cross-flow lift 0.8 (f̂0 0.18 ± 0.08), in-line C_x 0.85, α 0.15, C_D 1.2, and the drag
349+
amplification of Chaplin et al. (2005a, Eq. 4) on the in-line drag alone (`VIV AMPLITUDE` with
350+
`VIV DAMPING 0 0 1`). Against the experimenters' processed results, read from the vector
351+
graphics of their blind-trial presentation: the dominant cross-flow mode is right in 5 of 9
352+
cases and within one in the rest; the largest mean in-line displacement is within ±17% in 7 of
353+
9 (+34% in case 2, −25% in case 9; the blind predictions under-predicted it by 20–40%);
354+
the largest cross-flow amplitude is −44% to +4%, and the overall standard deviation of the
355+
cross-flow curvature −39% to +26%. Half the time step and 128 elements leave the mode and
356+
change the mean in-line displacement and the cross-flow curvature by at most 2.6% (the in-line
357+
curvature by up to 10%), except in two cases: case 5 beats in the 40 s window (its peak
358+
amplitude moves by up to 20%), and case 9 settles in mode 7 instead of 8 at half the time
359+
step.
360+
342361
- **L3-W SJTU steel catenary riser, cross-flow VIV in uniform current**
343362
([Wang et al., 2014](https://cabledyn.readthedocs.io/en/latest/references.html#ref-wang2014);
344363
[Thorsen et al., 2017](https://cabledyn.readthedocs.io/en/latest/references.html#ref-thorsen2017)):

‎doc/references.rst‎

Lines changed: 8 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -286,6 +286,14 @@ Verification and validation references
286286
*Journal of Fluids and Structures* **21**\ (1), 3–24.
287287
https://doi.org/10.1016/j.jfluidstructs.2005.04.010
288288

289+
.. _ref-chaplin2005b:
290+
291+
- **Chaplin, J. R., Bearman, P. W., Cheng, Y., Fontaine, E., Graham, J. M. R., Herfjord, K.,
292+
Huera Huarte, F. J., Isherwood, M., Lambrakos, K., Larsen, C. M., Meneghini, J. R., Moe, G.,
293+
Pattenden, R. J., Triantafyllou, M. S. & Willden, R. H. J. (2005).** Blind predictions of
294+
laboratory measurements of vortex-induced vibrations of a tension riser. *Journal of Fluids and
295+
Structures* **21**\ (1), 25–40. https://doi.org/10.1016/j.jfluidstructs.2005.05.016
296+
289297
Comparison codes
290298
----------------
291299

‎doc/theory.rst‎

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -1451,7 +1451,7 @@ The row serves two uses:
14511451

14521452
- With :math:`(0, 0, 1)` and the drag factor of :ref:`Chaplin et al. (2005) <ref-chaplin2005>`,
14531453
the amplification acts on the mean in-line drag alone, as measured, while the cross-flow drag
1454-
stays Morison's.
1454+
stays Morison's (validation case L3-D, the Delta Flume riser in a stepped current).
14551455
- :math:`(0.31, 0.89, 0)` is Thorsen's cross-flow model. It drops the linear part
14561456
:math:`\tfrac12\rho D C_{dn}U\dot y` of Morison's cross-flow damping, so it is consistent with
14571457
cross-flow VIV alone. An in-line force that turns with the relative flow can then drive an

‎validation/README.md‎

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -16,7 +16,7 @@ redistributed.
1616
| [`RELEASE_0_1_1.md`](RELEASE_0_1_1.md) | The same for v0.1.1 |
1717
| [`RELEASE_0_1_0.md`](RELEASE_0_1_0.md) | The same for v0.1.0 |
1818
| [`bodies/`](bodies/README.md) | Rigid-body, rod and shared-anchor cases with MoorDyn-C twins, stored references and pass limits |
19-
| [`experiments/`](experiments/README.md) | Holcombe et al. (2025) static lazy-wave, Bergdahl et al. (2016) dynamic-chain, Chaplin et al. (2005) riser natural-frequency and Wang et al. (2014) catenary-riser VIV comparisons |
19+
| [`experiments/`](experiments/README.md) | Holcombe et al. (2025) static lazy-wave, Bergdahl et al. (2016) dynamic-chain, Chaplin et al. (2005) riser natural-frequency and stepped-current VIV, and Wang et al. (2014) catenary-riser VIV comparisons |
2020
| [`PERFORMANCE_0_1_0.md`](PERFORMANCE_0_1_0.md) | Wall time of CableDyn 0.1.0, MoorDyn-C and MoorDyn-F at equal accuracy on five mooring, cable, buoy and coupled cases |
2121
| [`performance/`](performance/README.md) | Same-host wall-clock records of the L5 cases: the resolved lazy-wave spans, the one-hour VolturnUS-S mooring and the tension-only chain |
2222
| [`PAPER_REPRODUCTION.md`](PAPER_REPRODUCTION.md) | Every CableDyn result in the journal article, re-run with the release defaults and in paper mode |

‎validation/experiments/README.md‎

Lines changed: 3 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -2,7 +2,7 @@
22

33
# Experimental comparisons
44

5-
This directory lets reviewers reproduce CableDyn's comparisons with four published physical
5+
This directory lets reviewers reproduce CableDyn's comparisons with five published physical
66
experiments. Each subdirectory gives the data source, the translation of the published
77
parameters into a CableDyn model, the assessed quantity, the reproduction commands and the
88
committed results.
@@ -12,6 +12,7 @@ committed results.
1212
| [`holcombe/`](holcombe/README.md) | Holcombe et al. (2025), 1:70 static lazy-wave cable | Finite-EI power cable |
1313
| [`bergdahl/`](bergdahl/README.md) | Bergdahl et al. (2016), 33 m dynamically scaled chain | Tension-only mooring chain |
1414
| [`chaplin/`](chaplin/README.md) | Chaplin et al. (2005), 13.12 m vertical tension riser, still-water natural frequencies | Finite-EI riser, modal analysis |
15+
| [`delta_flume/`](delta_flume/README.md) | Chaplin et al. (2005), 13.12 m vertical tension riser, stepped current, blind-trial cases 1–9 | Finite-EI riser, synchronisation VIV, cross-flow and in-line |
1516
| [`wang_scr/`](wang_scr/README.md) | Wang et al. (2014), truncated steel catenary riser in uniform current, cross-flow VIV | Finite-EI riser, synchronisation VIV |
1617

17-
The results are summarised as cases L3-H, L3-B, L3-C and L3-W in [`VALIDATION.md`](../../VALIDATION.md).
18+
The results are summarised as cases L3-H, L3-B, L3-C, L3-D and L3-W in [`VALIDATION.md`](../../VALIDATION.md).
Lines changed: 130 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,130 @@
1+
<!-- SPDX-License-Identifier: Apache-2.0 -->
2+
3+
# Delta Flume vertical riser in a stepped current: cross-flow and in-line VIV
4+
5+
This directory compares CableDyn's VIV with the nine blind-trial cases of the Delta Flume riser
6+
tests. Chaplin et al. (2005a), <https://doi.org/10.1016/j.jfluidstructs.2005.04.010>, describe the
7+
riser and the tests, and Chaplin et al. (2005b),
8+
<https://doi.org/10.1016/j.jfluidstructs.2005.05.016>, the blind predictions made for them. The
9+
lower 5.94 m of the 13.12 m riser is in a uniform current of 0.16–0.95 m/s, the rest in still
10+
water. The VIV coefficients are a generic set; nothing is fitted to these measurements. The
11+
still-water natural frequencies of the same riser are case L3-C
12+
([`../chaplin`](../chaplin/README.md)).
13+
14+
## Model and data
15+
16+
- **Riser:** as L3-C: 13.12 m between pinned joints, D 28 mm, EI 29.9 N m², mass ratio 3.0 with
17+
the internal water (1.847 kg/m), fresh water, C_a 1. From the project's mechanical-properties
18+
page (University of Southampton, archived; `provenance.json`): EA 5.88 MN, structural damping
19+
0.33 % of critical, top spring 11.4 kN/m.
20+
- **Top spring:** in series with the riser, one effective axial stiffness
21+
EA_eff = L/(1/k + L/EA) = 1.459e5 N. The unstretched length of each case is iterated until the
22+
static top tension in the current is the case's mean top tension. A rigid top would turn the
23+
current's bow into tension (1799 N instead of 1002 N in case 9) and stiffen the riser.
24+
- **Current:** the towing speed U over the lower 5.94 m (the bottom of the carriage's vacuum
25+
tank), still water above, with a 2 cm linear step between them.
26+
- **Cases (slide 3 of the presentation below):**
27+
28+
| Case | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
29+
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
30+
| U (m/s) | 0.16 | 0.21 | 0.31 | 0.40 | 0.54 | 0.60 | 0.70 | 0.85 | 0.95 |
31+
| Mean top tension (N) | 405 | 407 | 457 | 506 | 598 | 670 | 743 | 923 | 1002 |
32+
| Std of top tension (N) | 2 | 3 | 3 | 8 | 15 | 14 | 8 | 14 | 65 |
33+
34+
- **VIV (all cases):**
35+
- synchronisation lift C_l 0.8 in the band f̂0 0.18 ± 0.08;
36+
- in-line force C_x 0.85, α 0.15 (Ulveseter et al. 2018);
37+
- C_D 1.2;
38+
- a `VIV AMPLITUDE` table with C_v 0.8 constant and the drag amplification of Chaplin et al.
39+
(2005a, Eq. 4), CdAmp = 1 + 2.3 s + 1.7 s², s = (A/D)/√2, at A/D 0–1.5;
40+
- `VIV DAMPING` `0 0 1`: the amplification acts on the in-line drag only, and the cross-flow drag
41+
stays Morison's.
42+
- **Measurements:** the experimenters' processed results, from their presentation of the blind
43+
trial (Chaplin et al., Trondheim, October 2004). The slides are vector graphics, so the values are
44+
the plotted coordinates mapped through the tick labels, not a pixel digitisation:
45+
- `measured_summary.csv`, from slides 17–19: maximum cross-flow displacement, maximum mean and
46+
maximum dynamic in-line displacement (in D), and the overall standard deviation of the in-line
47+
and cross-flow curvature (κD). Its `U` column is the speed read from each point; it matches
48+
the tabulated speed within 0.006 m/s, which checks the axis mapping.
49+
- `envelopes/`: the measured envelopes along the riser of each case (slides 7–15), with their
50+
columns, checks and the assumed curvature scale in [`envelopes/README.md`](envelopes/README.md).
51+
- The dominant cross-flow mode numbers 2, 3, 4, 5, 6, 6, 7, 7, 7 (slide 23).
52+
- **Assumed:** the 11.4 kN/m top spring (the page also lists 38.1 kN/m, without saying which tests
53+
used which); the 0.33 % structural damping as bending damping of a pure bending mode at 2 Hz (the
54+
page gives no frequency).
55+
- **CableDyn:** 64 elements; dt the largest of 5, 2.5, 2, 1 and 0.5 ms at or below 1/200 of the
56+
shedding period D/(0.18 U) (2.5 ms in cases 1–3, 1 ms in 4–7, 0.5 ms in 8–9); `VIVrmsWindow`
57+
0.25 s; 40 s, statistics over t > 15 s.
58+
- **Metrics:** x is in-line and y cross-flow, both from the line between the joints.
59+
- dominant cross-flow mode: the pinned-pinned sine with the largest r.m.s. projection of y;
60+
- maximum cross-flow amplitude: the largest half peak-to-peak of y along the riser, against the
61+
slide-18 maximum;
62+
- maximum mean in-line displacement: the largest time mean of x;
63+
- dominant cross-flow frequency (`response_comparison.csv` only): the spectral peak of y a
64+
quarter of the length above the lower joint, at a resolution of 0.04 Hz;
65+
- overall standard deviation of curvature: the r.m.s. over the nodes of the standard deviation
66+
of the curvature (second differences of the node positions), times D.
67+
68+
## Reproduce
69+
70+
From the repository root, with `path/to/cabledyn.exe` the release executable or a local build:
71+
72+
```powershell
73+
python validation/experiments/delta_flume/delta_flume_viv.py `
74+
path/to/cabledyn.exe validation/experiments/delta_flume/work `
75+
--summary validation/experiments/delta_flume
76+
```
77+
78+
The nine cases run in parallel (`--jobs`), in about two minutes on a 24-core workstation. `--cases`
79+
(for example `5,9`) selects cases; `--segments`, `--dt-scale` and `--spring` change the mesh, the
80+
time step and the top spring.
81+
82+
## Results
83+
84+
CableDyn / measured; the measured cross-flow amplitude is the slide-18 maximum, with the half
85+
peak-to-peak of the measured envelope in brackets.
86+
87+
| Case | U (m/s) | Mode | A_CF/D | Mean IL/D | Std κD, CF | Std κD, IL | Mean top tension (N) |
88+
| --- | --- | --- | --- | --- | --- | --- | --- |
89+
| 1 | 0.16 | 2 / 2 | 0.653 / 0.757 (0.763) | 1.19 / 1.06 | 5.7e-5 / 9.3e-5 | 3.5e-5 / 5.0e-5 | 409 / 405 |
90+
| 2 | 0.21 | 3 / 3 | 0.601 / 0.579 (0.561) | 1.60 / 1.19 | 1.12e-4 / 0.89e-4 | 7.2e-5 / 3.4e-5 | 413 / 407 |
91+
| 3 | 0.31 | 4 / 4 | 0.629 / 0.779 (0.809) | 3.27 / 3.45 | 2.06e-4 / 2.70e-4 | 0.91e-4 / 1.95e-4 | 476 / 457 |
92+
| 4 | 0.40 | **4** / 5 | 0.692 / 0.674 (0.595) | 4.78 / 4.97 | 2.30e-4 / 3.18e-4 | 1.37e-4 / 2.69e-4 | 541 / 506 |
93+
| 5 | 0.54 | 6 / 6 | 0.779 / 0.843 (0.889) | 6.39 / 6.69 | 4.10e-4 / 4.81e-4 | 2.10e-4 / 2.31e-4 | 656 / 598 |
94+
| 6 | 0.60 | 6 / 6 | 0.606 / 0.709 (0.779) | 6.78 / 8.13 | 4.39e-4 / 4.77e-4 | 2.57e-4 / 4.57e-4 | 734 / 670 |
95+
| 7 | 0.70 | **6** / 7 | 0.737 / 0.777 (0.717) | 8.32 / 8.90 | 4.68e-4 / 6.47e-4 | 2.64e-4 / 3.03e-4 | 836 / 743 |
96+
| 8 | 0.85 | **6** / 7 | 0.781 / 0.907 (0.890) | 9.65 / 11.18 | 4.91e-4 / 6.89e-4 | 2.99e-4 / 4.48e-4 | 1046 / 923 |
97+
| 9 | 0.95 | **8** / 7 | 0.599 / 1.074 (0.996) | 10.16 / 13.51 | 6.88e-4 / 7.36e-4 | 3.70e-4 / 6.24e-4 | 1128 / 1002 |
98+
99+
- **Dominant cross-flow mode:** right in 5 of 9 cases and within one in the other four (one low in
100+
cases 4, 7 and 8, one high in case 9). Four of the eleven blind predictions found 7 or 8 of the 9
101+
(slide 24).
102+
- **Mean in-line displacement:** within ±17 % in 7 of 9 cases; +34 % in case 2, where the
103+
measured maximum is 1.2 D, and −25 % in case 9. The blind predictions under-predicted the drag
104+
amplification, and with it the mean in-line displacement, by 20–40 % (slide 26).
105+
- **Cross-flow amplitude:** −44 % to +4 % against the slide-18 maxima (−40 % to +16 % against
106+
the envelopes), within ±12 %, the scatter between the two measured values, in cases 2, 4, 5
107+
and 7. The −44 % of case 9 goes with the response in mode 8.
108+
- **Curvature:** the cross-flow standard deviation is −39 % to +26 %, low in every case but 2
109+
(−6 % to −29 % in cases 3–9); the in-line one −53 % to +110 %. The blind predictions' r.m.s.
110+
curvatures were 20 % to 180 % of the measured (slide 26).
111+
- **Top tension:** the static top tension in the current is the measured mean, but the drag
112+
amplification bows the riser further: the mean top tension of the run is 1–13 % above the
113+
measured mean (7–13 % in cases 4–9), so the run is stiffer than the test at the higher
114+
speeds.
115+
- **Convergence (`provenance.json`):**
116+
- cases 1–4 and 6–8: half the time step leaves the mode and changes the mean in-line
117+
displacement and the cross-flow curvature standard deviation by at most 0.6 %, the peak
118+
amplitude by at most 4.5 % and the in-line curvature by at most 10 % (case 8); 128 elements
119+
leave the mode and change them by at most 2.6 %, 4.2 % and 9 %;
120+
- case 5 beats in the 40 s window: its peak amplitude changes by −17 % and −20 % and its
121+
in-line curvature by −10 % and +25 %, while the other metrics move by at most 9 %;
122+
- case 9 has two responses: at half the time step it settles in mode 7 (5.80 Hz, A/D 0.725,
123+
mean in-line displacement 10.63 D), with the base step and with 128 elements in mode 8
124+
(6.60 Hz), which an 80 s run keeps.
125+
- **Top spring 38.1 kN/m (`--spring 38.1e3`):** the mean top tension of the run is up to 14 %
126+
higher and the mean in-line displacement 2–16 % lower, within ±17 % in 4 of 9 cases; the mode
127+
is right in 5 of 9 (case 9 in mode 7, case 5 in mode 5, case 8 in mode 5).
128+
129+
`response_comparison.csv` holds the per-case values with their errors, and `summary.json` the
130+
statistics and the SHA-256 of the executable.

0 commit comments

Comments
 (0)