Skip to content

Commit c46eb64

Browse files
authored
docs: published VIV coefficient sets with their sources (#161)
The theory manual gains "Published coefficient sets": each set with its source, the tests it was fitted to and the line-type columns it maps to: - Thorsen et al. (2016): the excitation curve Cv(y0/D) fitted to the 44 NDP riser tests (0.35 at 0, a maximum of 1.00 at 0.46, zero from 0.66) and the cross-flow damping 0.31 + 0.89 y0/D; - Thorsen et al. (2017): the Wang et al. (2014) riser set (L3-W); - Ulveseter et al. (2018): the in-line Cx 0.85, alpha 0.15; - Andersen et al. (2024a): the forced-oscillation set of their Table 3 (Cv 1.2, CD 1.1, Ca 1.0, band 0.11-0.26, i.e. dF 0.075 about cF 0.185 here) and the unified Cv of about 2.0; - Andersen et al. (2024b): the cross-flow average of their Table 3 (1.28, 0.131, 0.066; their in-line set belongs to another in-line synchronisation form, which is said); - Facchinetti et al. (2004): CL0 0.3, St 0.2, eps 0.3, A 12. Thorsen et al.'s curve, read from the vector figure, is given as a VIV AMPLITUDE table on 0.05 steps. Every value was read from the papers; the two Andersen references were checked against Crossref. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
1 parent befec35 commit c46eb64

3 files changed

Lines changed: 100 additions & 0 deletions

File tree

‎CHANGELOG.md‎

Lines changed: 4 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -100,6 +100,10 @@ All notable changes to CableDyn are recorded in this file. The format follows
100100
Thorsen et al. (2017) use for it: dominant strain frequency 0.992 Hz against the measured
101101
1.00 Hz, largest r.m.s. strain 7.3 % above the measured largest, station mean 3.6 % above;
102102
converged in mesh and time step to 0.2 %.
103+
- Theory manual, Published coefficient sets: the VIV coefficient sets of Thorsen et al. (2016,
104+
2017), Ulveseter et al. (2018), Andersen et al. (2024a, b) and Facchinetti et al. (2004), each
105+
with its source, its test data and the line-type columns it maps to, and Thorsen et al.'s
106+
excitation curve as a `VIV AMPLITUDE` table.
103107

104108
## [0.4.2] - 2026-11-09
105109

‎doc/references.rst‎

Lines changed: 13 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -107,6 +107,19 @@ Hydrodynamics and ocean environment
107107
and higher harmonic VIV of slender structures. *Applied Ocean Research* **90**, 101856.
108108
https://doi.org/10.1016/j.apor.2019.101856
109109

110+
.. _ref-andersen2024a:
111+
112+
- **Andersen, M. L., Sævik, S., Wu, J., Leira, B. J. & Langseth, H. (2024a).** Applying Bayesian
113+
optimization to predict parameters in a time-domain model for cross-flow vortex-induced
114+
vibrations. *Marine Structures* **94**, 103571. https://doi.org/10.1016/j.marstruc.2023.103571
115+
116+
.. _ref-andersen2024b:
117+
118+
- **Andersen, M. L., Sævik, S., Wu, J., Leira, B. J. & Langseth, H. (2024b).** Simulating
119+
vortex-induced vibrations in sheared current by using an empirical time-domain model with
120+
adaptive parameters. *Applied Ocean Research* **153**, 104284.
121+
https://doi.org/10.1016/j.apor.2024.104284
122+
110123
.. _ref-feeny2008:
111124

112125
- **Feeny, B. F. (2008).** A complex orthogonal decomposition for wave motion analysis.

‎doc/theory.rst‎

Lines changed: 83 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -1437,6 +1437,89 @@ with :math:`C_v = 0` and factor 2 the line settles at the static in-line offset
14371437
printed digits; Thorsen's form raises the steady cross-flow amplitude from :math:`A/D` 0.68 to 1.02;
14381438
and the drag, damping and VIV powers balance within 0.2 %.
14391439

1440+
.. _theory-viv-coefficients:
1441+
1442+
Published coefficient sets
1443+
~~~~~~~~~~~~~~~~~~~~~~~~~~
1444+
1445+
The VIV coefficients are empirical, and the published sets differ by test, Reynolds number range
1446+
and model form. The table gives each set with its source and the line-type columns it maps to.
1447+
``Cl dF cF`` are the cross-flow columns of the line type, with the synchronisation band
1448+
:math:`c_F \pm d_F` in non-dimensional frequency; ``ClX alpha`` is the ``VIV`` section row.
1449+
1450+
.. list-table::
1451+
:header-rows: 1
1452+
:widths: 30 34 36
1453+
1454+
* - Source and data
1455+
- Values
1456+
- In CableDyn
1457+
* - :ref:`Thorsen et al. (2016) <ref-thorsen2016>`: excitation curve fitted to the 44 NDP
1458+
riser tests (uniform and sheared flow, Re 8 000–65 000), their Fig. 7
1459+
- :math:`C_v(y_0/D)`: 0.35 at 0, a maximum of 1.00 at 0.46, zero from 0.66; cross-flow
1460+
damping :math:`C_{d,y} = 0.31 + 0.89\,y_0/D` (their Eq. 1)
1461+
- a ``VIV AMPLITUDE`` table (below); ``VIV DAMPING`` ``0.31 0.89 0``
1462+
* - :ref:`Thorsen et al. (2017) <ref-thorsen2017>`: the truncated catenary riser of
1463+
:ref:`Wang et al. (2014) <ref-wang2014>` in uniform current (Re about 3 000)
1464+
- :math:`C_v` 0.7, :math:`\hat f_0` 0.18, :math:`\Delta\hat f` 0.08, :math:`C_D` 1.2,
1465+
:math:`C_M` 2
1466+
- ``Cl dF cF`` = ``0.7 0.08 0.18``, ``Cd_n`` 1.2, ``Ca_n`` 1.0 (validation case L3-W)
1467+
* - :ref:`Ulveseter et al. (2018) <ref-ulveseter2018>`: in-line force at twice the
1468+
cross-flow frequency
1469+
- :math:`C_x` 0.85, :math:`\alpha` 0.15, with a cross-flow :math:`C_L` of 0.65
1470+
- ``VIV`` row ``0.85 0.15``; ``Cl`` 0.65
1471+
* - :ref:`Andersen et al. (2024a) <ref-andersen2024a>`, Table 3: the set calibrated to
1472+
low-Re forced-oscillation tests that they quote as the model's fixed values
1473+
- :math:`C_v` 1.2, :math:`C_D` 1.1, :math:`C_a` 1.0, :math:`\hat f_0` 0.18, band
1474+
0.11–0.26
1475+
- ``Cl`` 1.2, ``Cd_n`` 1.1, ``Ca_n`` 1.0; the band here is symmetric about ``cF``:
1476+
``dF cF`` = ``0.075 0.185`` spans 0.11–0.26
1477+
* - :ref:`Andersen et al. (2024a) <ref-andersen2024a>`: Bayesian optimisation against seven
1478+
tests of a rigid cylinder on a spring-supported pendulum rig (Re 4.2e4–1.2e5)
1479+
- unified :math:`C_v` "very close to 2.0"; the per-case optima scatter with flow speed
1480+
- ``Cl`` 2.0 (no unified band is tabulated)
1481+
* - :ref:`Andersen et al. (2024b) <ref-andersen2024b>`, Table 3: average of the per-case
1482+
optima for the 22 sheared-flow NDP tests
1483+
- cross-flow :math:`C_{v,y}` 1.28, :math:`\hat f_{0,y}` 0.131, :math:`\Delta\hat f_y` 0.066;
1484+
:math:`C_D` 1.16, :math:`C_a` 1.0
1485+
- ``Cl dF cF`` = ``1.28 0.066 0.131``, ``Cd_n`` 1.16; their in-line set (:math:`C_{v,x}`
1486+
1.09, :math:`\hat f_{0,x}` 0.321) belongs to an independent in-line synchronisation, not
1487+
the ``VIV`` row's form
1488+
* - :ref:`Facchinetti et al. (2004) <ref-facchinetti2004>`: wake oscillator with
1489+
acceleration coupling, fitted to forced-cylinder lift and lock-in data
1490+
- :math:`C_{L0}` 0.3, St 0.2 (sub-critical, :math:`300 < Re < 1.5\times10^5`),
1491+
:math:`\varepsilon` 0.3, :math:`A` 12
1492+
- ``WAKE OSCILLATOR`` row ``0.3 0.2 0.3 12``
1493+
1494+
Thorsen et al. (2016)'s curve, read from the vector figure and sampled every 0.05 in
1495+
:math:`y_0/D`, as a ``VIV AMPLITUDE`` table for a type ``riser`` (its ``Cv`` replaces ``Cl``;
1496+
the drag factor stays 1):
1497+
1498+
.. code-block:: text
1499+
1500+
--------------------- VIV AMPLITUDE ------------------------------------
1501+
TypeName AD Cv
1502+
(-) (-) (-)
1503+
riser 0.00 0.35
1504+
riser 0.05 0.48
1505+
riser 0.10 0.60
1506+
riser 0.15 0.70
1507+
riser 0.20 0.79
1508+
riser 0.25 0.86
1509+
riser 0.30 0.92
1510+
riser 0.35 0.96
1511+
riser 0.40 0.99
1512+
riser 0.45 1.00
1513+
riser 0.50 0.98
1514+
riser 0.55 0.82
1515+
riser 0.60 0.53
1516+
riser 0.65 0.10
1517+
riser 0.70 0.00
1518+
1519+
The sets do not transfer between structures without checking: Andersen et al. find optima that
1520+
scatter between tests with no trend in Reynolds number, and Thorsen et al. state that their curve
1521+
holds only in the Reynolds number range of the tests it was fitted to.
1522+
14401523
.. _theory-dry-buoyancy:
14411524

14421525
Buoyancy and wetting

0 commit comments

Comments
 (0)