The Delta Flume tests of Chaplin et al. (2005, J. Fluids Struct. 21, 3-24) are the stepped-current VIV benchmark of a 13.12 m vertical tension riser. Before any VIV comparison the riser model itself has to be right: its mass, added mass, bending stiffness and the tension that falls with the submerged weight down the line. Table 2 of the paper gives the first seven still-water natural frequencies at five top tensions, so CableDyn's modal analysis can be checked against 35 measured values with no fitted parameter. validation/experiments/chaplin/chaplin_natural_frequencies.py writes a deck per series (EI 29.9 N m^2, mass ratio 3.0 with the internal water, which reproduces the paper's 12.1 N/m submerged weight, pinned ends, the unstretched length that gives the Table 2 top tension), runs the modal analysis about the static state and compares. Assumed: fresh water, Ca 1, and EA 5.5e6 N, which the paper does not give. Result: 1.87 % high on average over 34 values, mean absolute error 2.28 %, largest 4.88 % (series A mode 1). The 35th, series C mode 2, is measured at 1.423 Hz against 1.619 Hz; its ratio to the first mode (1.82) departs from every other series (1.97-2.16), so it is reported apart and kept in the all-35 statistic (2.61 %). Ca 1.1 would bring the mean to +0.62 %; the default stays 1. 128 elements and ten times EA change no frequency by more than 3e-6 and 1.2e-4. Added to VALIDATION.md as L3-C, to the experiments index and the references; the reference is checked against Crossref. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
Codex Review Summary: ✅ CompletedThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
Owner
Author
|
@codex review |
|
Codex Review: Didn't find any major issues. What shall we delve into next? Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Adds validation case L3-C: the still-water natural frequencies of the Delta Flume vertical tension riser, against measurements, with no fitted parameter.
The Delta Flume tests of Chaplin et al. (J. Fluids Struct. 21, 2005, 3–24) are the stepped-current VIV benchmark of a 13.12 m riser. Before any VIV comparison, the riser model itself has to be right: its mass, added mass, bending stiffness, and the tension that falls with the submerged weight down the line. Table 2 of the paper gives the first seven still-water natural frequencies at five top tensions, so CableDyn's modal analysis can be checked against 35 measured values.
Model
validation/experiments/chaplin/chaplin_natural_frequencies.pywrites one deck per tension series, runs the modal analysis about the static state, and compares.EICa,EAResult
The 35th value, series C mode 2, is measured at 1.423 Hz against 1.619 Hz computed. Its ratio to the first mode (1.82) departs from every other series (1.97–2.16), so it is reported apart but kept in the all-35 statistic.
Sensitivity:
Ca = 1.1would bring the mean to +0.62 %; the default stays 1.EAchanges no frequency by more than 1.2e-4.Files
validation/experiments/chaplin/: script, README,natural_frequencies.csv, summary and provenance JSON.VALIDATION.md: the L3-C row and section.doc/references.rst; the reference is checked against Crossref.