Repository navigation
validation: cross-flow VIV of a steel catenary riser in uniform current (L3-W) - #160
Conversation
…nt (L3-W) The SJTU truncated steel catenary riser of Wang et al. (2014, Marine Structures 39, 131-156) in a 0.2 m/s uniform in-plane current is the case Thorsen et al. (2017, Marine Structures 51, 134-151) use to verify the time-domain synchronisation model that CableDyn's cross-flow VIV implements. It checks the VIV term on a curved, partly grounded riser with its own published coefficients, so no parameter is fitted. validation/experiments/wang_scr/wang_scr_uniform_current.py writes the deck (23.71 m riser between pinned joints, the top 21.0425 m out and 9 m up, D 0.024 m, 0.69 kg/m, EI 10.5 N m^2, EA 6.66e5 N; seabed 1 (kN/m)/m with friction 0.2; Cv 0.7, f0 0.18, df 0.08, CD 1.2, CM 2, cross-flow only), runs it and compares: - the r.m.s. dynamic cross-flow strain at the 25 stations of Thorsen et al. Fig. 17, read from the vector figure (axes calibrated on its tick marks; the figure's simulated maximum reads 99.6 % of the measured, as their text states); - the dominant strain frequency 8.25 m from the lower end. Result (200 elements, dt 0.005 s, 150 s): - frequency 0.992 Hz against the measured 1.00 Hz (their model 1.02 Hz, Davies et al. 2026 1.04 Hz); - largest r.m.s. strain 7.3 % above the measured largest (theirs 0.4 % below), the mean over the stations 3.6 % above; - one r.m.s. peak more along the span than the test (7 against 6), as theirs, so the station-by-station ratio scatters; - 400 elements and half the time step change the largest r.m.s. strain by 0.2 % and 0.1 % and leave the frequency unchanged. Added to VALIDATION.md as L3-W, to the experiments index and the references (Wang et al. 2014, Thorsen et al. 2017, Davies et al. 2026, checked against Crossref). Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
Codex Review Summary: ✅ CompletedThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
There was a problem hiding this comment.
💡 Codex Review
Here are some automated review suggestions for this pull request.
Reviewed commit: 37f19561b8
ℹ️ About Codex in GitHub
Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you
- Open a pull request for review
- Mark a draft as ready
- Comment "@codex review".
If Codex has suggestions, it will comment; otherwise it will react with 👍.
Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".
Review: the script runs CableDyn in the generated case folder, so a relative executable path (as in the README command) resolved against that folder and raised FileNotFoundError. The executable is resolved against the invocation directory first (or found on PATH for a bare name), and that path is run and hashed; a missing executable stops with its name. Checked with a relative path from another directory and with a missing one. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
|
Codex Review: Didn't find any major issues. What shall we delve into next? Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
Summary
New validation case L3-W: cross-flow VIV of the SJTU truncated steel catenary riser (Wang et al. 2014) in a 0.2 m/s uniform in-plane current. Thorsen et al. (2017) use this case to verify the time-domain synchronisation model that CableDyn's cross-flow VIV implements. Here CableDyn runs it with their published coefficients and no fitted parameter, on a curved riser that rests partly on the seabed.
CableDyn shows one more r.m.s. peak along the span than the test, as Thorsen et al.'s model does, so the station-by-station ratio scatters.
Convergence
The case
Files
validation/experiments/wang_scr/wang_scr_uniform_current.py: writes the deck, runs it and writes the comparison;measured_rms_strain.csv,rms_strain_comparison.csv,summary.json,provenance.json,README.md;VALIDATION.md: the L3-W row and section; experiments and validation indexes;doc/references.rst: Wang et al. 2014, Thorsen et al. 2017, Davies et al. 2026 (checked against Crossref);CHANGELOG.md.To reproduce:
Checks
-W;