Repository navigation
docs: published VIV coefficient sets with their sources - #161
Merged
Merged
Conversation
The theory manual gains "Published coefficient sets": each set with its source, the tests it was fitted to and the line-type columns it maps to: - Thorsen et al. (2016): the excitation curve Cv(y0/D) fitted to the 44 NDP riser tests (0.35 at 0, a maximum of 1.00 at 0.46, zero from 0.66) and the cross-flow damping 0.31 + 0.89 y0/D; - Thorsen et al. (2017): the Wang et al. (2014) riser set (L3-W); - Ulveseter et al. (2018): the in-line Cx 0.85, alpha 0.15; - Andersen et al. (2024a): the forced-oscillation set of their Table 3 (Cv 1.2, CD 1.1, Ca 1.0, band 0.11-0.26, i.e. dF 0.075 about cF 0.185 here) and the unified Cv of about 2.0; - Andersen et al. (2024b): the cross-flow average of their Table 3 (1.28, 0.131, 0.066; their in-line set belongs to another in-line synchronisation form, which is said); - Facchinetti et al. (2004): CL0 0.3, St 0.2, eps 0.3, A 12. Thorsen et al.'s curve, read from the vector figure, is given as a VIV AMPLITUDE table on 0.05 steps. Every value was read from the papers; the two Andersen references were checked against Crossref. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
Owner
Author
|
@codex review |
Codex Review Summary: ✅ CompletedThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
|
Codex Review: Didn't find any major issues. 🎉 Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
The VIV coefficients are empirical, and the published sets differ by test, Reynolds number range and model form. This adds "Published coefficient sets" to the theory manual. Each set comes with its source, the tests it was fitted to, and the line-type columns it maps to. Every value was read from the papers; nothing is quoted second-hand.
VIV AMPLITUDEtable;VIV DAMPING 0.31 0.89 0Cl dF cF = 0.7 0.08 0.18(case L3-W)VIVrow0.85 0.15Cl 1.2;dF cF = 0.075 0.185Cl 2.0Cl dF cF = 1.28 0.066 0.131; the in-line set uses another in-line form (said)WAKE OSCILLATOR 0.3 0.2 0.3 12Thorsen et al.'s excitation curve, read from the vector figure, is given as a
VIV AMPLITUDEtable on 0.05 steps.The section ends with the caveat both groups state. Andersen et al.'s per-case optima scatter with no trend in Reynolds number, and Thorsen et al.'s curve holds only in the Reynolds number range of the tests it was fitted to.
Changes
doc/theory.rst: new subsectiontheory-viv-coefficients, after Cross-flow damping;doc/references.rst: Andersen et al. (2024a, b), checked against Crossref;CHANGELOG.md.Checks
-W, pre-commit;