The WAKE OSCILLATOR section (Facchinetti et al. 2004) now acts on EI = 0 lines as well as finite-EI cables. Until now a deck with the wake oscillator on an EI = 0 line was refused.

On the taut line of the wake-oscillator gate, the two cores agree:

Finite-EI cable (EI 1) EI = 0 line Difference
Lock-in A/D (50-75 s) 0.5850 0.5856 0.1 %
Lock-in frequency 0.282 Hz 0.282 Hz 0
Uncoupled (A 0) A/D 0.0986 0.0989 0.3 %
Uncoupled frequency 0.298 Hz 0.298 Hz 0
Wake-lift power taken out by drag + damping 99.8 % 99.8 %

The wake's own frequency is St U/D = 0.30 Hz.

Model

At each free node next to a lifting element:

$$\ddot q + \varepsilon,\omega_f (q^2 - 1),\dot q + \omega_f^2 q = \frac{A}{D},\ddot y, \qquad \omega_f = 2\pi,\mathrm{St},\frac{U_a}{D}$$

  • Lift: $\tfrac14 \rho D C_{L0}, q, U^2$ per unit length over the node's tributary length, in the direction of the synchronisation lift.
  • Forcing: $\ddot y$ is the node's smoothed cross-flow acceleration (the same average with its two neighbours that the synchronisation phase uses).
  • Wake frequency: $U_a$ is the ambient flow normal to the line.
  • Time stepping: as on the finite-EI cable, through the shared CD_VIV_Wake_Advance. $q$ is predicted at the step's evaluation point under the step-start forcing, then advanced from the committed state with the acceleration linear over the step.

State

$(q, \dot q)$ is held in the line's VIV phase and first motion-statistic slots. So the rollback, step-recovery, sub-step and checkpoint copies carry it with no new plumbing, and the checkpoint layout of an EI = 0 line does not change. CD_Set_Model_VIV takes the per-element $(\mathrm{St}, \varepsilon, A)$ as an optional wake argument. It refuses in-line VIV and amplitude tables with the wake oscillator, as the finite-EI cable does.

Tests

  • tests/test_viv_wake_deck.f90:
    • W1-W3 (lock-in, power balance, CL0 = 0 bit-identical to no section) now run on both cores;
    • new W5 checks that the cores agree;
    • W4: the EI = 0 refusal is replaced by refusals of a mixed line and of an EI = 0 type that keeps Cl.
  • tests/test_viv_coupled.f90: the wake case puts the wake oscillator on the EI = 0 riser too. The checkpoint restart continues bit for bit, a rebuild without the VIV state does not, and a rewound step repeats.
  • python/tests/test_deck_file.py: the reader accepts the wake oscillator on an EI = 0 line and still refuses a kept Cl.

Checks

  • ctest under both BLAS kernels and a Debug subset;
  • pytest against the native build;
  • ruff, Sphinx -W, pre-commit.

The WAKE OSCILLATOR section now acts on EI = 0 lines as on finite-EI
cables; a deck with the wake oscillator on an EI = 0 line was refused.

At each free node next to a lifting element the van der Pol wake
variable q drives the lift 1/4 rho D CL0 q U^2 over the node's
tributary length, in the direction of the synchronisation lift. The
forcing is the node's smoothed cross-flow acceleration, and the wake
frequency that of the ambient flow normal to the line. The step follows
the finite-EI cable: q predicted at the step's evaluation point under
the step-start forcing, then advanced from the committed state with the
acceleration linear over the step (the shared CD_VIV_Wake_Advance).

The state (q, dq/dt) is held in the line's VIV phase and first motion
statistic, so the rollback, step-recovery, sub-step and checkpoint
copies carry it unchanged; the checkpoint layout of an EI = 0 line does
not change. CD_Set_Model_VIV takes the per-element (St, eps, A) as an
optional wake argument; it refuses in-line VIV and amplitude tables
with it, as the finite-EI cable does.

Gates (tests/test_viv_wake_deck.f90, test_viv_coupled.f90):
- the taut line of the wake gate with EI = 0 locks in at 0.282 Hz and
  A/D 0.5856, against 0.5850 for the finite-EI cable (0.1 %), and
  responds uncoupled (A 0) at the wake's 0.298 Hz, A/D 0.0989 against
  0.0986;
- the drag and damping take out the wake-lift power within 0.3 %;
- CL0 0 is the deck without the section, bit for bit;
- on the coupled route a checkpoint restart continues bit for bit with
  the EI = 0 wake state, a rebuild without it does not, and a rewound
  step repeats;
- a line mixing the two models and an EI = 0 type that keeps its Cl
  are refused by name.

The Python deck reader accepts the wake oscillator on EI = 0 lines.

Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
@SMI-Lab-Inha

Copy link
Copy Markdown
Owner Author

@codex review

@chatgpt-codex-connector

chatgpt-codex-connector Bot commented Nov 14, 2026 •

Copy link
Copy Markdown
Codex Review Summary: ✅ Completed

This comment shows the latest Codex review activity on this pull request.

Review Status Commit Review trigger
📝 Code Review ✅ Completed 2026-11-14T15:39:10.670040Z cd98e39 Manual request
ℹ️ About Codex in GitHub

Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you

  • Open a pull request for review
  • Mark a draft as ready
  • Comment "@codex review" or "@codex security review".

Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings.

@read-the-docs-community

Copy link
Copy Markdown

Documentation build overview

📚 CableDyn | 🛠️ Build #35892725 | 📁 Comparing cd98e39 against latest (789cb6d)

  🔍 Preview build  

13 files changed · ± 13 modified

± Modified

@chatgpt-codex-connector

Copy link
Copy Markdown

Codex Review: Didn't find any major issues. Can't wait for the next one!

Reviewed commit: cd98e395ee

ℹ️ About Codex in GitHub

Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you

  • Open a pull request for review
  • Mark a draft as ready
  • Comment "@codex review".

If Codex has suggestions, it will comment; otherwise it will react with 👍.

Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".

@SMI-Lab-Inha
SMI-Lab-Inha merged commit 5e65151 into dev Nov 14, 2026
22 checks passed
@SMI-Lab-Inha
SMI-Lab-Inha deleted the feat/wake-oscillator-ei0 branch November 14, 2026 18:26
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant