9 changes: 6 additions & 3 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -44,11 +44,14 @@ All notable changes to CableDyn are recorded in this file. The format follows
- Wake-oscillator VIV: an optional `WAKE OSCILLATOR` section row `TypeName CL0 [St [eps [A]]]`
replaces the synchronisation lift of a type (which keeps `Cl` 0) by the van der Pol wake
oscillator of Facchinetti et al. (2004) with acceleration coupling (defaults St 0.2, eps 0.3,
A 12), distributed along finite-EI cables, standalone and coupled. The kernel follows the
A 12), distributed along finite-EI cables and at the nodes of `EI = 0` lines, standalone and
coupled. The kernel follows the
published forced-wake lift magnification within 2 %; on the taut example cable the wake locks
the cable in at its first mode (A/D 0.58 against 0.10 uncoupled) and the drag and damping take
out the wake lift's power within 0.3 %. Its state is in the step-recovery, snapshot and
checkpoint state; the Python deck reader and builder take the section.
out the wake lift's power within 0.3 %; the same line with `EI = 0` locks in within 0.1 % of
the cable's A/D at the same frequency. Its state is in the step-recovery, snapshot and
checkpoint state (on an `EI = 0` line, in the slots of the VIV phase and first motion
statistic); the Python deck reader and builder take the section.
- Amplitude-dependent VIV coefficients: an optional `VIV AMPLITUDE` section, rows
`TypeName AD Cv [CdAmp]`, gives a line type a table over the cross-flow amplitude ratio of the
coefficient `Cv` that replaces its `Cl` and a factor `CdAmp` of its normal drag coefficient, read
Expand Down
2 changes: 1 addition & 1 deletion doc/capabilities.rst
Original file line number Diff line number Diff line change
Expand Up @@ -159,7 +159,7 @@ Line and constitutive capability
* - Wake-oscillator VIV (``WAKE OSCILLATOR`` section ``CL0``, ``St``, ``eps``, ``A``)
- Standalone and coupled
- the van der Pol wake oscillator of Facchinetti et al. (2004) with acceleration coupling,
distributed along finite-EI cables in place of the synchronisation model
on ``EI = 0`` lines and along finite-EI cables in place of the synchronisation model
(:ref:`theory-viv-wake`), its state in the checkpoint
* - Amplitude-dependent VIV coefficients (``VIV AMPLITUDE`` section ``AD``, ``Cv``, ``CdAmp``)
- Standalone and coupled
Expand Down
4 changes: 2 additions & 2 deletions doc/driver_format.md
Original file line number Diff line number Diff line change
Expand Up @@ -1240,7 +1240,7 @@ Wake-oscillator vortex-induced vibration of a line type, the model of Facchinett
a van der Pol oscillator per node stands for the near wake and drives the cross-flow lift, coupled
to the cable's cross-flow acceleration (see [Wake oscillator](theory.rst)). It replaces the
synchronisation model of the LINE TYPES `Cl` column for that type, so the type keeps `Cl = 0`, and
it acts on finite-EI cables.
it acts on finite-EI cables and `EI = 0` lines alike.

```text
--------------------- WAKE OSCILLATOR ----------------------------------
Expand Down Expand Up @@ -1270,7 +1270,7 @@ Behaviour:
`VIVPow` carry the wake lift. A row with `CL0 = 0` leaves the run exactly as without it.
- A row fails if it is not `TypeName CL0 [St [eps [A]]]`, names an undefined or already named
type, or holds a value out of range; `CL0 > 0` fails on a type with `Cl > 0`. A line whose types
mix the two models fails, and so does an `EI = 0` line with the wake oscillator.
mix the two models fails.

### VIV AMPLITUDE (optional)

Expand Down
10 changes: 8 additions & 2 deletions doc/theory.rst
Original file line number Diff line number Diff line change
Expand Up @@ -1314,7 +1314,11 @@ oscillation and the van der Pol damping rate at the start of the interval, so a
:math:`\varepsilon` stays resolved; should the rate exceed :math:`0.2/\delta t` on the way, or the
result not be finite, the interval is redone with twice the sub-steps. The lift is integrated on a finite-EI cable at the Gauss
points of the synchronisation lift, :math:`q` interpolated between the element's end nodes, with
its exact position and velocity derivatives in the tangent at fixed :math:`q`. :math:`q` starts on
its exact position and velocity derivatives in the tangent at fixed :math:`q`. On an ``EI = 0``
line it acts at the free nodes as the synchronisation lift does, over the node's tributary length,
with the node's smoothed cross-flow acceleration (the average with its two neighbours) as the
forcing, and :math:`(q, \dot q)` takes the place of the phase and the first motion statistic in
the line's VIV state. :math:`q` starts on
its limit cycle at the node's phase seed, :math:`q = 2\cos\phi_0`, :math:`\dot q = 0`, and the
state is part of the step-recovery, snapshot and checkpoint state.

Expand All @@ -1326,7 +1330,9 @@ one-harmonic balance leaves out. On the taut cable of ``viv_taut_cable_inline.da
``Cl`` 0 and ``CL0`` 0.3 the cable locks in at 0.282 Hz, below the wake's own 0.30 Hz, at a
steady mid-span A/D of 0.58; with :math:`A` = 0 the uncoupled wake drives it at 0.298 Hz at A/D
0.10, and over the lock-in the drag and damping take out the wake lift's power within 0.3 %. The
wake oscillator acts on finite-EI cables, cross-flow only.
same line with ``EI = 0`` locks in at the same 0.282 Hz and A/D 0.586 (0.1 % from the finite-EI
cable), and 0.099 uncoupled (0.3 %). The wake oscillator acts on finite-EI cables and ``EI = 0``
lines, cross-flow only.

.. _theory-viv-amplitude:

Expand Down
2 changes: 1 addition & 1 deletion python/cabledyn/builder.py
Original file line number Diff line number Diff line change
Expand Up @@ -227,7 +227,7 @@ class LineType:
reference lift coefficient, the Strouhal number, the van der Pol
parameter and the acceleration coupling. It replaces the
synchronisation lift, so ``cl`` stays ``None`` or 0, and acts on
finite-EI cables. ``None`` leaves a trailing value out of the row (the
``EI = 0`` lines and finite-EI cables. ``None`` leaves a trailing value out of the row (the
solver takes 0.2, 0.3 and 12); a value given writes the ones before it.
viv_amplitude : list of tuples | None
Optional amplitude-dependent VIV coefficients of a type (Thorsen et al.
Expand Down
9 changes: 2 additions & 7 deletions python/cabledyn/deck_file.py
Original file line number Diff line number Diff line change
Expand Up @@ -4789,8 +4789,8 @@ def end_key(token: str) -> str:
for line_id, section_types in section_types_by_line.items()
if {line_type.lower() for line_type in section_types} & amp_type_names
}
# native build_one_hermite_cable and the EI = 0 line wiring: the wake oscillator and the
# cross-flow damping act on finite-EI cables only, and a cable takes one VIV model
# native build_one_hermite_cable and the EI = 0 line wiring: the cross-flow damping acts on
# finite-EI cables only, and a line takes one VIV model
for line_id, section_types in section_types_by_line.items():
types_used = {line_type.lower() for line_type in section_types}
if types_used & damp_type_names and line_id not in finite_line_ids:
Expand All @@ -4800,11 +4800,6 @@ def end_key(token: str) -> str:
)
if not types_used & wake_type_names:
continue
if line_id not in finite_line_ids:
raise DeckFormatError(
f"{self._label}: line {line_id}: the wake oscillator (WAKE OSCILLATOR "
"section) acts on finite-EI cables (EI > 0) only"
)
if types_used & viv_type_names:
raise DeckFormatError(
f"{self._label}: line {line_id}: a line takes one VIV model, but its types mix "
Expand Down
12 changes: 9 additions & 3 deletions python/tests/test_deck_file.py
Original file line number Diff line number Diff line change
Expand Up @@ -4888,15 +4888,15 @@ def test_wake_oscillator_rows_are_read_and_kept(tmp_path, rows, expected):
(None, ("chain 0.3 0.2 0.0",), "St > 0, eps > 0 and A >= 0"),
(None, ("chain 0.3 0.2 0.3 -1",), "St > 0, eps > 0 and A >= 0"),
("lift", ("chain 0.3",), "give the type LINE TYPES Cl 0"),
("ei0", ("chain 0.3",), "acts on finite-EI cables (EI > 0) only"),
("lift ei0", ("chain 0.3",), "give the type LINE TYPES Cl 0"),
],
)
def test_wake_oscillator_rows_follow_the_native_checks(base, rows, message):
text = _DYNAMIC
if base == "lift":
if base and "lift" in base:
row = "chain 0.252 390.0 1.674e9 -1.0 1.0e4 1.37 0.64 1.0 0.0"
text = _edit(text, (row, row + " 0.8"))
elif base == "ei0":
if base and "ei0" in base:
text = _edit(text, ("1.674e9 -1.0 1.0e4 1.37", "1.674e9 -1.0 0.0 1.37"))
with pytest.raises(DeckFormatError, match=re.escape(message)):
DeckFile.from_text(_with_section(text, "WAKE OSCILLATOR", *rows))
Expand Down Expand Up @@ -5066,6 +5066,12 @@ def test_wake_oscillator_cl0_zero_is_off_and_needs_no_finite_line():
DeckFile.from_text(_with_section(text, "WAKE OSCILLATOR", "chain 0.0"))


def test_wake_oscillator_acts_on_an_ei0_line():
# native init_one_model installs the wake oscillator on EI = 0 lines as on finite-EI cables
text = _edit(_DYNAMIC, ("1.674e9 -1.0 1.0e4 1.37", "1.674e9 -1.0 0.0 1.37"))
DeckFile.from_text(_with_section(text, "WAKE OSCILLATOR", "chain 0.3 0.2 0.3 12"))


def test_viv_is_accepted_on_the_coupled_route():
text = _edit(_STATIC, (_VIV_ROW, _VIV_ROW + " 0.8"))
DeckFile.from_text(text)
Expand Down
2 changes: 1 addition & 1 deletion python/tests/test_end_to_end.py
Original file line number Diff line number Diff line change
Expand Up @@ -280,7 +280,7 @@ def test_generated_study_runs_on_the_real_driver(tmp_path):
(
"wake-ei0-line",
[_WAKE_LIFT, _WAKE_SECTION, ("-0.8 1.0 1.2", "-0.8 0.0 1.2")],
False,
True,
),
]

Expand Down
25 changes: 21 additions & 4 deletions src/CableDyn_DeckDriver.f90
Original file line number Diff line number Diff line change
Expand Up @@ -10498,6 +10498,8 @@ RECURSIVE SUBROUTINE init_one_model(ln, sections, types, points, opts, model, Er
REAL(wp), ALLOCATABLE :: ve_ead(:), ve_bas(:), ve_bad(:), ve_ambl(:), ve_vbet(:)
REAL(wp), ALLOCATABLE :: viv_cl(:), viv_cf(:), viv_df(:), viv_clx(:), viv_al(:), viv_hh(:)
REAL(wp), ALLOCATABLE :: viv_tix(:), viv_amp3(:, :, :), viv_dia(:)
! the WAKE OSCILLATOR rows per element (C_L0, St, eps, A; C_L0 0 where none)
REAL(wp), ALLOCATABLE :: viv_wo(:, :)
INTEGER, ALLOCATABLE :: viv_ampn(:)
LOGICAL, ALLOCATABLE :: syr_el(:)
REAL(wp) :: anchor(3), fairlead(3), mode1_omega
Expand Down Expand Up @@ -10538,8 +10540,9 @@ RECURSIVE SUBROUTINE init_one_model(ln, sections, types, points, opts, model, Er
hydro_can(SIZE(l0)), hydro_cat(SIZE(l0)), ve_ead(SIZE(l0)), ve_bas(SIZE(l0)), &
ve_bad(SIZE(l0)), ve_ambl(SIZE(l0)), ve_vbet(SIZE(l0)), viv_cl(SIZE(l0)), viv_cf(SIZE(l0)), &
viv_df(SIZE(l0)), syr_el(SIZE(l0)), viv_clx(SIZE(l0)), viv_al(SIZE(l0)), viv_hh(SIZE(l0)), &
viv_tix(SIZE(l0)), viv_dia(SIZE(l0)))
viv_tix(SIZE(l0)), viv_dia(SIZE(l0)), viv_wo(4, SIZE(l0)))
viv_tix = CD_ZERO
viv_wo = CD_ZERO
viv_dia = CD_ZERO
viv_cl = CD_ZERO
viv_cf = CD_ZERO
Expand Down Expand Up @@ -10604,8 +10607,10 @@ RECURSIVE SUBROUTINE init_one_model(ln, sections, types, points, opts, model, Er
hydro_cat(e) = types(line_section_type(sections, ln%id, i))%cat
viv_cl(e) = types(line_section_type(sections, ln%id, i))%cl
IF (types(line_section_type(sections, ln%id, i))%wo_cl0 > CD_ZERO) THEN
CALL fail(ErrStat, ErrMsg, 'line '//TRIM(int_to_str(ln%id))//': the wake oscillator (WAKE '// &
'OSCILLATOR section) acts on finite-EI cables (EI > 0) only'); RETURN
viv_wo(:, e) = [types(line_section_type(sections, ln%id, i))%wo_cl0, &
types(line_section_type(sections, ln%id, i))%wo_st, &
types(line_section_type(sections, ln%id, i))%wo_eps, &
types(line_section_type(sections, ln%id, i))%wo_a]
END IF
IF (types(line_section_type(sections, ln%id, i))%cdy_a >= CD_ZERO) THEN
CALL fail(ErrStat, ErrMsg, 'line '//TRIM(int_to_str(ln%id))//': the cross-flow damping (VIV '// &
Expand Down Expand Up @@ -10633,6 +10638,14 @@ RECURSIVE SUBROUTINE init_one_model(ln, sections, types, points, opts, model, Er
viv_hh = viv_hh(SIZE(viv_hh):1:-1)
viv_tix = viv_tix(SIZE(viv_tix):1:-1)
viv_dia = viv_dia(SIZE(viv_dia):1:-1)
viv_wo = viv_wo(:, SIZE(viv_wo, 2):1:-1)
IF (ANY(viv_wo(1, :) > CD_ZERO) .AND. ANY(viv_cl > CD_ZERO)) THEN
CALL fail(ErrStat, ErrMsg, 'line '//TRIM(int_to_str(ln%id))//': a line takes one VIV model, but its '// &
'types mix the synchronisation lift (LINE TYPES Cl > 0) and the wake oscillator (WAKE '// &
'OSCILLATOR section)'); RETURN
END IF
! the wake oscillator: the lift coefficient passed on is C_L0
IF (ANY(viv_wo(1, :) > CD_ZERO)) viv_cl = viv_wo(1, :)
ba = ba(SIZE(ba):1:-1)
ve_ead = ve_ead(SIZE(ve_ead):1:-1)
ve_bas = ve_bas(SIZE(ve_bas):1:-1)
Expand Down Expand Up @@ -10925,7 +10938,11 @@ RECURSIVE SUBROUTINE init_one_model(ln, sections, types, points, opts, model, Er
! the VIV AMPLITUDE tables, left unallocated (absent below) on a line without one
CALL viv_amp_tables(types, viv_tix, viv_amp3, viv_ampn)
! with the in-line VIV of the VIV section where a type has ClX > 0
IF (ANY(viv_clx > CD_ZERO)) THEN
IF (ANY(viv_wo(1, :) > CD_ZERO)) THEN
! the wake oscillator: cl is C_L0, the band unused
CALL CD_Set_Model_VIV(model, opts%rhoW, viv_cl, viv_dia, viv_cf, viv_df, tw, es, em, &
phase_seed=seed, tangent_reversed=.NOT. ln%ends_swapped, wake=viv_wo(2:4, :))
ELSE IF (ANY(viv_clx > CD_ZERO)) THEN
CALL CD_Set_Model_VIV(model, opts%rhoW, viv_cl, viv_dia, viv_cf, viv_df, tw, es, em, &
phase_seed=seed, tangent_reversed=.NOT. ln%ends_swapped, clx=viv_clx, &
il_alpha=viv_al, chh=viv_hh, amp=viv_amp3, amp_n=viv_ampn)
Expand Down
Loading
Loading