6 changes: 6 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -117,6 +117,12 @@ All notable changes to CableDyn are recorded in this file. The format follows
one generic coefficient set and the drag amplification on the in-line drag alone, against the
experimenters' measured envelopes and summaries: dominant mode right in 5 of 9 and within one in
all, mean in-line displacement within 17 % in 7 of 9, cross-flow amplitude −45 % to +4 %.
- Validation case L3-N (`validation/experiments/ndp_riser`): cross-flow VIV of the NDP 38 m
high-mode riser of Trim et al. (2005) at its 22 uniform-flow tow speeds, with four coefficient
sets against the measured maximum r.m.s. cross-flow strain (Thorsen et al. 2016, Fig. 8), the
dominant frequency and σ/D: the set Ulveseter et al. (2019) fitted to these tests matches strain
(r.m.s. log error 0.178), frequency and amplitude together; Andersen et al.'s (2024b)
sheared-flow average 0.186; the generic set, blind, 0.277.
- Theory manual, Published coefficient sets: the VIV coefficient sets of Thorsen et al. (2016,
2017), Ulveseter et al. (2018), Andersen et al. (2024a, b) and Facchinetti et al. (2004), each
with its source, its test data and the line-type columns it maps to, and Thorsen et al.'s
Expand Down
5 changes: 3 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -171,8 +171,9 @@ layout is described in the architecture notes in the repository.
## Validation

CableDyn is verified against analytical solutions and compared with MoorDyn,
OrcaFlex, two physical experiments (Holcombe lazy-wave, Bergdahl dynamic chain),
the IEA 15 MW VolturnUS-S reference systems, and coupled OpenFAST runs. Results,
OrcaFlex, six published physical experiments (Holcombe lazy-wave, Bergdahl dynamic
chain, Chaplin riser natural frequencies and stepped-current VIV, Wang catenary-riser VIV,
NDP high-mode riser VIV), the IEA 15 MW VolturnUS-S reference systems, and coupled OpenFAST runs. Results,
acceptance criteria, and reproduction commands are in
the [validation record](https://cabledyn.readthedocs.io/en/latest/validation.html); data and scripts are in
[`validation/`](https://cabledyn.readthedocs.io/en/latest/validation.html).
Expand Down
27 changes: 27 additions & 0 deletions VALIDATION.md
Original file line number Diff line number Diff line change
Expand Up @@ -84,6 +84,7 @@ article's methods, are compared in
| **L3-C** | Chaplin Delta Flume riser, still-water natural frequencies | measured modes 1–7 at five tensions | mean error +1.87%, mean absolute 2.28%, largest 4.88% (34 of 35; one outlier reported) | full published table, no fitted parameter | Pass |
| **L3-D** | Chaplin Delta Flume riser in a stepped current, blind-trial cases 1–9, cross-flow and in-line VIV | measured dominant mode, peak cross-flow amplitude, mean in-line displacement, curvature standard deviations | mode right in 5/9, within one in 9/9; mean in-line within ±17% in 7/9 (−25% to +34%); cross-flow amplitude −45% to +4%; cross-flow curvature −39% to +26% | generic coefficient set, no fitted parameter | Pass measured |
| **L3-W** | SJTU steel catenary riser in 0.2 m/s current, cross-flow VIV | measured r.m.s. strain (25 stations) and dominant frequency | frequency 0.992 vs 1.00 Hz; max r.m.s. strain +7.3%, station mean +3.6% | published coefficient set, no fitted parameter | Pass |
| **L3-N** | NDP 38 m high-mode riser in uniform flow, 0.3–2.4 m/s (22 tests), cross-flow VIV | measured maximum r.m.s. cross-flow strain, dominant frequency, spatial-mean σ/D | strain r.m.s. log error: Ulveseter et al. (2019) set 0.178, Andersen et al. (2024b) 0.186, generic set 0.277, Thorsen et al. (2016) 0.363 (their own simulation 0.187); f D/U 0.145 / 0.134 / 0.192 / 0.193 vs 0.143 measured | generic set blind; the other sets fitted by their authors to NDP tests (implementation check) | Pass measured |
| **L-fig** | Along-arc curvature overlay (CableDyn / OrcaFlex / MoorDyn-F ±4×) | 3-code committed record | CableDyn peak 0.11% from OrcaFlex | <0.5% | Pass |
| **L4-1** | Coupled platform + mooring | synthetic reference | bit-for-bit | — | Pass |
| **L4-1b** | VolturnUS-S coupled platform + power cable | OpenFAST v5.0.0 (CompMooring 5 vs 3) | platform DOFs <0.6% (3-seed DLC-1.1); fairlead and anchor <0.001% static | <3% platform | Pass |
Expand Down Expand Up @@ -373,6 +374,32 @@ scripts, results, and source provenance are in
the test, as theirs, so the station-by-station ratio scatters. 400 elements and half the time step
change the largest r.m.s. strain by 0.2% and 0.1%.

- **L3-N NDP high-mode riser, cross-flow VIV in uniform flow**
([Trim et al., 2005](https://cabledyn.readthedocs.io/en/latest/references.html#ref-trim2005);
[Thorsen et al., 2016](https://cabledyn.readthedocs.io/en/latest/references.html#ref-thorsen2016)):
the 38 m bare riser towed horizontally at the 22 uniform-flow speeds, 0.3–2.4 m/s, with the
rig's clump-weight tension as an axial spring in series (4 kN in still water, 3.5 kN/m from the
reported 4–6 kN range). Four coefficient sets on the same model, compared with the maximum
r.m.s. cross-flow strain of each test (Thorsen et al.'s Fig. 8, read from the vector figure), the
dominant frequency and the spatial-mean σ/D (Trim et al.'s Figs. 18 and 16, read by eye from
raster figures):
- the set Ulveseter et al. (2019) fitted to these tests matches every metric: strain r.m.s. log
error 0.178 (Thorsen et al.'s own fitted simulation 0.187), f D/U 0.145 against 0.143
measured, σ/D within 6% cross-flow and 3% in line, an implementation check of the
synchronisation, in-line and higher-harmonic forces;
- the cross-flow average Andersen et al. (2024b) fitted to the sheared-flow tests gives 0.186 at
f D/U 0.134, with σ/D 57% high;
- the generic set, blind, gives 0.277 with σ/D within 2%, at f D/U 0.192;
- Thorsen et al.'s own fitted curve and damping give 0.363 at f D/U 0.193; keeping Morison's
linear cross-flow damping moves the frequency to 0.153.

At single speeds the response converges at 1.0 m/s for four of the five sets (half the time
step and 400 elements move the strain by at most 0.8%; 18.5% for the fifth) but not at 2.4 m/s,
where the mix of neighbouring high modes moves the strain by up to 20%. The statistics over
the 22 speeds hold: the full sweep at half the time step gives r.m.s. log errors 0.280, 0.187,
0.184 and 0.375 for the generic, Andersen, Ulveseter and Thorsen sets, f D/U within 0.001 and
σ/D within 1.4%.

## L4 coupled OpenFAST

- **L4-1 synthetic** (`l4_platform_mooring`): 6-DOF platform moored by three taut
Expand Down
14 changes: 14 additions & 0 deletions doc/references.rst
Original file line number Diff line number Diff line change
Expand Up @@ -294,6 +294,20 @@ Verification and validation references
laboratory measurements of vortex-induced vibrations of a tension riser. *Journal of Fluids and
Structures* **21**\ (1), 25–40. https://doi.org/10.1016/j.jfluidstructs.2005.05.016

.. _ref-trim2005:

- **Trim, A. D., Braaten, H., Lie, H. & Tognarelli, M. A. (2005).** Experimental investigation
of vortex-induced vibration of long marine risers. *Journal of Fluids and Structures*
**21**\ (3), 335–361. https://doi.org/10.1016/j.jfluidstructs.2005.07.014

.. _ref-fontaine2011:

- **Fontaine, E., Marcollo, H., Vandiver, K., Triantafyllou, M., Larsen, C., Tognarelli, M.,
Constantinides, Y. & Oakley, O. (2011).** Reliability based factors of safety for VIV fatigue
using NDP riser high mode VIV tests. *ASME 2011 30th International Conference on Ocean,
Offshore and Arctic Engineering (OMAE2011)*, Volume 7: CFD and VIV; Offshore Geotechnics,
511–522. https://doi.org/10.1115/OMAE2011-49820

Comparison codes
----------------

Expand Down
2 changes: 1 addition & 1 deletion validation/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,7 @@ redistributed.
| [`RELEASE_0_1_1.md`](RELEASE_0_1_1.md) | The same for v0.1.1 |
| [`RELEASE_0_1_0.md`](RELEASE_0_1_0.md) | The same for v0.1.0 |
| [`bodies/`](bodies/README.md) | Rigid-body, rod and shared-anchor cases with MoorDyn-C twins, stored references and pass limits |
| [`experiments/`](experiments/README.md) | Holcombe et al. (2025) static lazy-wave, Bergdahl et al. (2016) dynamic-chain, Chaplin et al. (2005) riser natural-frequency and stepped-current VIV, and Wang et al. (2014) catenary-riser VIV comparisons |
| [`experiments/`](experiments/README.md) | Holcombe et al. (2025) static lazy-wave, Bergdahl et al. (2016) dynamic-chain, Chaplin et al. (2005) riser natural-frequency and stepped-current VIV, Wang et al. (2014) catenary-riser VIV and Trim et al. (2005) NDP high-mode riser VIV comparisons |
| [`PERFORMANCE_0_1_0.md`](PERFORMANCE_0_1_0.md) | Wall time of CableDyn 0.1.0, MoorDyn-C and MoorDyn-F at equal accuracy on five mooring, cable, buoy and coupled cases |
| [`performance/`](performance/README.md) | Same-host wall-clock records of the L5 cases: the resolved lazy-wave spans, the one-hour VolturnUS-S mooring and the tension-only chain |
| [`PAPER_REPRODUCTION.md`](PAPER_REPRODUCTION.md) | Every CableDyn result in the journal article, re-run with the release defaults and in paper mode |
Expand Down
5 changes: 3 additions & 2 deletions validation/experiments/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,7 +2,7 @@

# Experimental comparisons

This directory lets reviewers reproduce CableDyn's comparisons with five published physical
This directory lets reviewers reproduce CableDyn's comparisons with six published physical
experiments. Each subdirectory gives the data source, the translation of the published
parameters into a CableDyn model, the assessed quantity, the reproduction commands and the
committed results.
Expand All @@ -14,5 +14,6 @@ committed results.
| [`chaplin/`](chaplin/README.md) | Chaplin et al. (2005), 13.12 m vertical tension riser, still-water natural frequencies | Finite-EI riser, modal analysis |
| [`delta_flume/`](delta_flume/README.md) | Chaplin et al. (2005), 13.12 m vertical tension riser, stepped current, blind-trial cases 1–9 | Finite-EI riser, synchronisation VIV, cross-flow and in-line |
| [`wang_scr/`](wang_scr/README.md) | Wang et al. (2014), truncated steel catenary riser in uniform current, cross-flow VIV | Finite-EI riser, synchronisation VIV |
| [`ndp_riser/`](ndp_riser/README.md) | Trim et al. (2005), NDP 38 m high-mode riser in uniform flow, cross-flow VIV with a generic and three published coefficient sets | Finite-EI riser, synchronisation VIV |

The results are summarised as cases L3-H, L3-B, L3-C, L3-D and L3-W in [`VALIDATION.md`](../../VALIDATION.md).
The results are summarised as cases L3-H, L3-B, L3-C, L3-D, L3-W and L3-N in [`VALIDATION.md`](../../VALIDATION.md).
Loading
Loading