Repository navigation
validation: FLOTANT power-cable specimen VIV in tow tests (L3-F) - #175
Conversation
The OD 48 mm research cable of the FLOTANT tests at MARIN (de Wilde, Heijnsdijk & de Ridder 2021, Deliverable D5.5, MARIN report 30995-53-DWB): 6.4 m hanging from the carriage with a 200 kg clump, towed at the 40 speeds of 0.025-1.0 m/s. It tests cross-flow and in-line VIV of a real cable section against three published coefficient sets, none fitted to these tests, on a structure identified only from the specimen's forced-oscillation RAOs. validation/experiments/flotant/flotant_viv.py writes a deck per case, runs them in parallel (reused when deck and executable are unchanged) and compares: - tow: A/D_rms = sigma/OD at 1/2L, 3/4L and L, cross-flow and in line, at the same test speed, the model's displacement processed as the report's accelerometer motions (the g theta/omega^2 tilt term, the 3.5 rad/s high-pass); Ur with f1 1.77 Hz as Appendix 3; 60 s runs, statistics after 20 s, dt 2 ms; - rao: the in-air (5 and 10 mm) and in-water (5 mm) RAOs of Appendices 1 and 2, the structural check. The line follows the report's FEM tables node by node, in fresh water (Table 2-2 implies 1000 kg/m^3), with the clump or counterweight as a 20 kN/m axial spring in series. What the tests leave open is identified from the RAOs: cable EI 1650 N m^2 and bending damping 130 N m^2 s from the in-air resonance (the tables' EI 3000 needs MARIN's empirical factor 1.10), and in water a link chain bending with EI 100 N m^2 and the clump held laterally by 32.5 kN/m and 20 N s/m, which give the measured split of the first in-water mode (r.m.s. log error 0.46 in surge against 1.19 for MARIN's fixed clump and 1.17 for a free one). Sets, checked against the articles: - uls19, Ulveseter et al. (2019), Table 1 (Cl 0.85, cF 0.144, dF 0.064, ClX 0.75, alpha 0.15, Chh 1.5), fitted to the NDP riser: blind here; - b1, the generic set of the Delta Flume case (Cl 0.8, cF 0.18, dF 0.08, ClX 0.85, alpha 0.15, Chaplin's drag amplification, VIV DAMPING 0 0 1): blind; - wake, Facchinetti et al. (2004) (CL0 0.3, St 0.2, eps 0.3, A 12): blind. Result on the second-order VIV phase update (#171) (cross-flow r.m.s. log error over the three stations, Ur >= 3): - uls19 0.731: the first peak at 1/2L is 0.755 at Ur 5.30 against 0.776 at 5.58, but the rise starts at a lower speed (0.42 against 0.18 at Ur 3.53), the lock-in releases at Ur 7.06 against 5.88 (1.2 Ur late) and the upper branch stays at 0.64-0.71 above Ur 9 where the test falls to 0.18-0.44; - b1 0.594: 38 % low at the peak (0.483), releases at the measured Ur; - wake 1.208: 62 % low (0.296). With MARIN's fixed clump or a free clump (End B Free) uls19 scores 0.721 and 0.692 but releases at Ur 8.83 and 9.12 and misses the RAOs. extract_d55.py reads the data from the report's PDF (FEM tables from the text, the RAO charts from the vector graphics, Appendix 3 from the raster images calibrated on the grid lines; every point maps to a tested speed within 0.0085 m/s). The caveats of the data are stated: the Ur basis (1.77 Hz against the 1.3 Hz first in-water mode of Sec. 5.3), the bottom tension (1436 N in Table 6-1 against about 1700 N in the FEM table) and the towing direction alternating with speed. Half the time step, two elements per table element and 120 s runs change no A/D_rms by more than 0.006 at five speeds; the RAO scores move by at most 0.001. The default command run into a new work directory reproduces the committed record byte for byte. Added to VALIDATION.md as L3-F, to the experiments index, the changelog and the references (de Wilde et al. 2021, from the report's PDF; no DOI); the top-level README now names the seven published experiments. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
Codex Review Summary: ✅ CompletedThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
There was a problem hiding this comment.
💡 Codex Review
Here are some automated review suggestions for this pull request.
Reviewed commit: 01f0d3b305
ℹ️ About Codex in GitHub
Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you
- Open a pull request for review
- Mark a draft as ready
- Comment "@codex review".
If Codex has suggestions, it will comment; otherwise it will react with 👍.
Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".
flotant_viv.py and ndp_riser_viv.py reuse a folder's result.json when its inputs, executable and analysis key match. A rerun with changed inputs replaced the inputs but left the old result.json and executable stamp in place, so if the run then failed or was interrupted, the next attempt saw matching inputs and a matching key and returned the previous model's results. The result, the stamp and the output are now removed before the inputs are written (checked with a failing executable). A tow selection entirely below Ur 3 (for example --speeds 0.1) has no ratio in the scoring band, so its r.m.s. log errors are None, and the console line raised a TypeError before the comparison CSV and summary were written. The console line now prints n/a for those scores. The committed records are unchanged. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
|
Codex Review: Didn't find any major issues. Nice work! Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
Summary
New validation case L3-F: the OD 48 mm research power cable of the FLOTANT tow tests at MARIN (de Wilde, Heijnsdijk & de Ridder 2021, Deliverable D5.5). A 6.4 m length hangs from the carriage with a 200 kg clump and is towed at 40 speeds from 0.025 to 1.0 m/s.
The case compares cross-flow and in-line VIV of a real cable section with three published coefficient sets. None of the sets is fitted to these tests. The structure is identified only from the specimen's forced-oscillation RAOs.
Result: no set predicts these tests. The best set matches the peak height but locks in early and releases 1.2 Ur late.
uls19(Ulveseter et al. 2019, Table 1; NDP riser)b1(generic Delta Flume set, Chaplin drag amplification)wake(Facchinetti et al. 2004 wake oscillator)The errors are taken over 1/2L, 3/4L and L at Ur ≥ 3.
uls19: the response rises at a lower speed than measured (A/D 0.42 against 0.18 at Ur 3.53). Above Ur 9 it stays on an upper branch at 0.64–0.71, where the test falls to 0.18–0.44.b1: 38 % low at the peak, but it releases at the measured Ur.wake: 62 % low.How the case is built
Data (
extract_d55.py, from the report's PDF):Structure: the line follows the report's FEM tables node by node, in fresh water. Table 2-2 implies 1000 kg/m³.
Identified from the RAOs (
raocomparison, Appendices 1 and 2), where the tests leave the structure open:This reproduces the measured split of the first in-water mode: surge r.m.s. log error 0.46, against 1.19 for a fixed clump and 1.17 for a free one.
Tow processing: A/D_rms = σ/OD at 1/2L, 3/4L and L, cross-flow and in line, at the test speed.
Stated caveats of the data:
Convergence and reproducibility
Checked on this build:
response_comparison.csv,rao_comparison.csvandsummary.jsonbyte for byte.Checks
On the branch rebased onto dev 3d779fb (#173):
-W; theref-dewilde2021anchor and the new relative links resolve.