9 changes: 9 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -123,6 +123,15 @@ All notable changes to CableDyn are recorded in this file. The format follows
dominant frequency and σ/D: the set Ulveseter et al. (2019) fitted to these tests matches strain
(r.m.s. log error 0.178), frequency and amplitude together; Andersen et al.'s (2024b)
sheared-flow average 0.186; the generic set, blind, 0.277.
- Validation case L3-F (`validation/experiments/flotant`): VIV of the FLOTANT OD 48 mm
power-cable specimen of de Wilde et al. (2021) with its 200 kg clump weight at the 40 tow
speeds, cross-flow and in-line A/D_rms at three stations, with three published coefficient
sets none of which is fitted to these tests, on a structure identified from the specimen's
in-air and in-water RAOs. The set of Ulveseter et al. (2019) gives the first cross-flow peak
(0.755 against 0.776 at mid-length) but responds from a lower speed and releases 1.2 Ur late
(cross-flow r.m.s. log error 0.731); the generic set is 38 % low at the peak and releases at
the measured speed (0.594); the wake oscillator of Facchinetti et al. (2004) is 62 % low
(1.208).
- Theory manual, Published coefficient sets: the VIV coefficient sets of Thorsen et al. (2016,
2017), Ulveseter et al. (2018), Andersen et al. (2024a, b) and Facchinetti et al. (2004), each
with its source, its test data and the line-type columns it maps to, and Thorsen et al.'s
Expand Down
4 changes: 2 additions & 2 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -171,9 +171,9 @@ layout is described in the architecture notes in the repository.
## Validation

CableDyn is verified against analytical solutions and compared with MoorDyn,
OrcaFlex, six published physical experiments (Holcombe lazy-wave, Bergdahl dynamic
OrcaFlex, seven published physical experiments (Holcombe lazy-wave, Bergdahl dynamic
chain, Chaplin riser natural frequencies and stepped-current VIV, Wang catenary-riser VIV,
NDP high-mode riser VIV), the IEA 15 MW VolturnUS-S reference systems, and coupled OpenFAST runs. Results,
NDP high-mode riser VIV, FLOTANT power-cable VIV), the IEA 15 MW VolturnUS-S reference systems, and coupled OpenFAST runs. Results,
acceptance criteria, and reproduction commands are in
the [validation record](https://cabledyn.readthedocs.io/en/latest/validation.html); data and scripts are in
[`validation/`](https://cabledyn.readthedocs.io/en/latest/validation.html).
Expand Down
32 changes: 30 additions & 2 deletions VALIDATION.md
Original file line number Diff line number Diff line change
Expand Up @@ -86,6 +86,7 @@ article's methods, are compared in
| **L3-D** | Chaplin Delta Flume riser in a stepped current, blind-trial cases 1–9, cross-flow and in-line VIV | measured dominant mode, peak cross-flow amplitude, mean in-line displacement, curvature standard deviations | mode right in 5/9, within one in 9/9; mean in-line within ±17% in 7/9 (−25% to +34%); cross-flow amplitude −45% to +4%; cross-flow curvature −39% to +26% | generic coefficient set, no fitted parameter | Pass measured |
| **L3-W** | SJTU steel catenary riser in 0.2 m/s current, cross-flow VIV | measured r.m.s. strain (25 stations) and dominant frequency | frequency 0.992 vs 1.00 Hz; max r.m.s. strain +7.3%, station mean +3.6% | published coefficient set, no fitted parameter | Pass |
| **L3-N** | NDP 38 m high-mode riser in uniform flow, 0.3–2.4 m/s (22 tests), cross-flow VIV | measured maximum r.m.s. cross-flow strain, dominant frequency, spatial-mean σ/D | strain r.m.s. log error: Ulveseter et al. (2019) set 0.178, Andersen et al. (2024b) 0.186, generic set 0.277, Thorsen et al. (2016) 0.363 (their own simulation 0.187); f D/U 0.145 / 0.134 / 0.192 / 0.193 vs 0.143 measured | generic set blind; the other sets fitted by their authors to NDP tests (implementation check) | Pass measured |
| **L3-F** | FLOTANT OD 48 mm power-cable specimen with a 200 kg clump, tow tests at 0.025–1.0 m/s (40 tests), cross-flow and in-line VIV | measured A/D_rms (σ/OD) at 1/2L, 3/4L and L (de Wilde et al. 2021, App. 3) | CF r.m.s. log error (Ur ≥ 3): Ulveseter et al. (2019) set 0.731, generic set 0.594, wake oscillator 1.208; first peak at 1/2L 0.755 / 0.483 / 0.296 vs 0.776 measured; release Ur 7.06 / 5.89 / 5.30 vs 5.88 | published VIV sets, none fitted to these tests; structure identified from the specimen's in-air and in-water RAOs | Pass measured |
| **L-fig** | Along-arc curvature overlay (CableDyn / OrcaFlex / MoorDyn-F ±4×) | 3-code committed record | CableDyn peak 0.11% from OrcaFlex | <0.5% | Pass |
| **L4-1** | Coupled platform + mooring | synthetic reference | bit-for-bit | — | Pass |
| **L4-1b** | VolturnUS-S coupled platform + power cable | OpenFAST v5.0.0 (CompMooring 5 vs 3) | platform DOFs <0.6% (3-seed DLC-1.1); fairlead and anchor <0.001% static | <3% platform | Pass |
Expand Down Expand Up @@ -305,8 +306,9 @@ initialisation.

### Physical experiments

No line or load parameter is fitted to any of the experiments. Inputs, reduction
scripts, results, and source provenance are in
No line or load parameter is fitted to the measurements a case is compared with (L3-F
identifies its structure from forced-oscillation tests of the same specimen, separate from
the tow tests it predicts). Inputs, reduction scripts, results, and source provenance are in
[`validation/experiments`](https://github.com/SMI-Lab-Inha/CableDyn/tree/main/validation/experiments).

- **L3-H Holcombe static lazy-wave test**
Expand Down Expand Up @@ -401,6 +403,32 @@ scripts, results, and source provenance are in
0.184 and 0.375 for the generic, Andersen, Ulveseter and Thorsen sets, f D/U within 0.001 and
σ/D within 1.4%.

- **L3-F FLOTANT power-cable specimen, cross-flow and in-line VIV in tow tests**
([de Wilde et al., 2021](https://cabledyn.readthedocs.io/en/latest/references.html#ref-dewilde2021)):
the 6.4 m OD 48 mm cable hanging from the carriage with its 200 kg clump weight, towed at the 40
speeds of 0.025–1.0 m/s, compared with the measured A/D_rms (σ/OD) at 1/2L, 3/4L and L, the
model's displacements processed as the report's accelerometer motions (tilt term, 3.5 rad/s
high-pass). The line follows the report's FEM tables node by node. The structure the tests
leave open is identified from the specimen's forced-oscillation RAOs, not from the tow data:
the cable's EI (1650 N m², where the tables' 3000 N m² needs an empirical factor to match the
resonance) and bending damping from the in-air RAOs (resonance at the measured 1.7 Hz, peaks
7.4 and 7.2 against 8.7 and 5.9 at 5 and 10 mm), and in water a bending link chain and a
laterally restrained clump that reproduce the measured split of the first mode (peaks 1.2 and
1.9 Hz against 1.3 and 1.8 Hz; r.m.s. log error 0.46 against 1.19 with MARIN's fixed clump).
Three published VIV sets, none fitted to these tests (r.m.s. log error of the cross-flow
A/D_rms over the three stations, Ur ≥ 3):
- the set Ulveseter et al. (2019) fitted to the NDP riser gives the first peak at mid-length,
0.755 at Ur 5.30 against 0.776 at Ur 5.58, but responds from a lower speed (0.42 against
0.18 at Ur 3.53), releases at Ur 7.06 against 5.88 and holds 0.64–0.71 above Ur 9 where the
test falls to 0.18–0.44: 0.731;
- the generic set is 38% low at the peak (0.483) and releases at the measured Ur: 0.594;
- the wake oscillator of Facchinetti et al. (2004) is 62% low (0.296): 1.208.

No set predicts the speed range of the lock-in. With MARIN's fixed clump or a free clump the
same set scores 0.721 and 0.692 but releases at Ur 8.83 and 9.12 and misses the in-water RAOs.
Half the time step, two elements per table element and 120 s runs change no A/D_rms by more
than 0.006 at five speeds; the default run reproduces the committed record byte for byte.

## L4 coupled OpenFAST

- **L4-1 synthetic** (`l4_platform_mooring`): 6-DOF platform moored by three taut
Expand Down
8 changes: 8 additions & 0 deletions doc/references.rst
Original file line number Diff line number Diff line change
Expand Up @@ -308,6 +308,14 @@ Verification and validation references
Offshore and Arctic Engineering (OMAE2011)*, Volume 7: CFD and VIV; Offshore Geotechnics,
511–522. https://doi.org/10.1115/OMAE2011-49820

.. _ref-dewilde2021:

- **de Wilde, J., Heijnsdijk, R. & de Ridder, E.-J. (2021).** *D5.5 – Report on VIV
(hydrodynamic) behaviour.* FLOTANT project deliverable 210430-FLT-WP5_D-5-5_V0 (MARIN report
30995-53-DWB), Maritime Research Institute Netherlands, 30 April 2021. EU Horizon 2020 grant
agreement 815289 (https://doi.org/10.3030/815289); public deliverable, no DOI.
https://flotantproject.eu/wp-content/uploads/2021/11/210430_FLT-D5.5_VIV_test_v0.pdf

Comparison codes
----------------

Expand Down
2 changes: 1 addition & 1 deletion validation/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,7 @@ redistributed.
| [`RELEASE_0_1_1.md`](RELEASE_0_1_1.md) | The same for v0.1.1 |
| [`RELEASE_0_1_0.md`](RELEASE_0_1_0.md) | The same for v0.1.0 |
| [`bodies/`](bodies/README.md) | Rigid-body, rod and shared-anchor cases with MoorDyn-C twins, stored references and pass limits |
| [`experiments/`](experiments/README.md) | Holcombe et al. (2025) static lazy-wave, Bergdahl et al. (2016) dynamic-chain, Chaplin et al. (2005) riser natural-frequency and stepped-current VIV, Wang et al. (2014) catenary-riser VIV and Trim et al. (2005) NDP high-mode riser VIV comparisons |
| [`experiments/`](experiments/README.md) | Holcombe et al. (2025) static lazy-wave, Bergdahl et al. (2016) dynamic-chain, Chaplin et al. (2005) riser natural-frequency and stepped-current VIV, Wang et al. (2014) catenary-riser VIV, Trim et al. (2005) NDP high-mode riser VIV and de Wilde et al. (2021) FLOTANT power-cable VIV comparisons |
| [`PERFORMANCE_0_1_0.md`](PERFORMANCE_0_1_0.md) | Wall time of CableDyn 0.1.0, MoorDyn-C and MoorDyn-F at equal accuracy on five mooring, cable, buoy and coupled cases |
| [`performance/`](performance/README.md) | Same-host wall-clock records of the L5 cases: the resolved lazy-wave spans, the one-hour VolturnUS-S mooring and the tension-only chain |
| [`PAPER_REPRODUCTION.md`](PAPER_REPRODUCTION.md) | Every CableDyn result in the journal article, re-run with the release defaults and in paper mode |
Expand Down
5 changes: 3 additions & 2 deletions validation/experiments/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,7 +2,7 @@

# Experimental comparisons

This directory lets reviewers reproduce CableDyn's comparisons with six published physical
This directory lets reviewers reproduce CableDyn's comparisons with seven published physical
experiments. Each subdirectory gives the data source, the translation of the published
parameters into a CableDyn model, the assessed quantity, the reproduction commands and the
committed results.
Expand All @@ -15,5 +15,6 @@ committed results.
| [`delta_flume/`](delta_flume/README.md) | Chaplin et al. (2005), 13.12 m vertical tension riser, stepped current, blind-trial cases 1–9 | Finite-EI riser, synchronisation VIV, cross-flow and in-line |
| [`wang_scr/`](wang_scr/README.md) | Wang et al. (2014), truncated steel catenary riser in uniform current, cross-flow VIV | Finite-EI riser, synchronisation VIV |
| [`ndp_riser/`](ndp_riser/README.md) | Trim et al. (2005), NDP 38 m high-mode riser in uniform flow, cross-flow VIV with a generic and three published coefficient sets | Finite-EI riser, synchronisation VIV |
| [`flotant/`](flotant/README.md) | de Wilde et al. (2021), FLOTANT OD 48 mm power-cable specimen with a clump weight, tow tests and forced-oscillation RAOs, cross-flow and in-line VIV with three published coefficient sets | Finite-EI cable, synchronisation and wake-oscillator VIV |

The results are summarised as cases L3-H, L3-B, L3-C, L3-D, L3-W and L3-N in [`VALIDATION.md`](../../VALIDATION.md).
The results are summarised as cases L3-H, L3-B, L3-C, L3-D, L3-W, L3-N and L3-F in [`VALIDATION.md`](../../VALIDATION.md).
Loading
Loading