Repository navigation
validation: SJTU flexible cylinder VIV in oscillatory flow (L3-O) - #180
Merged
Merged
Conversation
The tests of Fu, Wang, Baarholm, Wu & Larsen (2014): a 4 m flexible cylinder (D 24 mm, EI 10.5 N m^2, pretension 500 N) moved across its axis through still water, A_m 0.68 m (KC 178) at periods 16.5, 10.2 and 8.45 s (U_R,max 4, 6.5 and 7.9). The relative flow reverses twice per cycle, so the case tests the VIV models through flow reversal and on the accelerating and decelerating halves of each half-cycle, where Fu et al. measure different amplitudes (hysteresis). validation/experiments/fu_oscillatory/fu_oscillatory_viv.py writes a deck per run, runs them in parallel (reused when deck and executable are unchanged) and compares the cross-flow A/D at mid-span (station CF4) against the instantaneous U_R on the two paths with the measured paths of Figs. 15-17, and the share of each half-cycle above sqrt(2)/2 of its peak with the article's lock-in shares (about 17, 34 and 50 %). extract_fu2014.py reads the paths from the figures, raster images calibrated on the plot frame and traced by colour; the traced gaps between the paths (0.164 at U_R 3.5, 0.222 at 4) match the figures' annotations 0.15D and 0.2D. Three published sets, none fitted to these tests (uls19, b1, wake, as in the FLOTANT and NDP cases), each with a VIV FRAME row: the cylinder moves through still water, where without it the wake oscillator never sheds. The primary runs take Tf 0.2 s; the motion period is 23-44 periods of f1, around the 30 the frame's two conditions need, so the record reports the runs without the row and with Tf 0.1 and 0.3 s. Results (A/D r.m.s. error over both paths; largest A/D): - every run converges through the flow reversals; - U_R,max 4: the wake oscillator gives the measured largest A/D (0.280 against 0.286), the generic set is 65 % high, uls19 barely responds; - U_R,max 6.5 and 7.9: every set holds the lock-in while the flow slows, the mean gap between the paths 2-5 times the measured one and the largest A/D 1.3-2.3 times the measured; the wake oscillator comes closest (0.177 and 0.132). Without the row the generic set scores 0.034 at U_R,max 4, the best of any run, but keeps the deceleration hold at 6.5 and 7.9. Half the time step and 80 elements change the largest A/D by at most 0.1 % (generic set, wake oscillator) and 4.1 % (uls19). The default command run into a new work directory reproduces response_comparison.csv and summary.json byte for byte. Added to VALIDATION.md as L3-O, to the experiments indexes, the top-level README, the changelog and the references (Fu et al. 2014, from the article's first page and footers). Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
Owner
Author
|
@codex review |
Codex Review Summary: ✅ CompletedThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
|
Codex Review: Didn't find any major issues. Bravo. Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Validation case L3-O: the SJTU flexible cylinder of Fu et al. (2014), moved harmonically across its axis through still water.
The relative flow reverses twice per cycle, so this case tests what a steady current cannot:
No model parameter is fitted to these tests.
What is compared
uls19,b1,wake).VIV FRAMErow. Without it the wake oscillator never sheds, because a cylinder moving through still water sees no ambient flow.Tf0.2 s. The motion period is 23–44 periods of f₁, around the 30 that the frame's two conditions need (docs: in-line drag amplification includes the in-line damping; VIV FRAME scale separation #174), so the record also reports runs with no row and withTf0.1 and 0.3 s.Results (primary runs)
uls19barely responds.VIV FRAMErow: the generic set scores 0.034 at U_R,max 4, the best of any run, but still holds the lock-in at 6.5 and 7.9.Convergence and reproducibility
b1andwake, and by 4.1 % foruls19.Tf0.1 and 0.3 s: move the synchronisation sets' largest A/D by up to 21 %, and the wake oscillator's by up to 11 %.response_comparison.csvandsummary.jsonbyte for byte.Data
extract_fu2014.pyreads the paths from the article's PDF. Figs. 15–17 are raster images.Docs
VALIDATION.mdgains a table row and a section.doc/references.rstare updated. The Fu et al. (2014) reference was checked against the article's first page and footers.Checks