The synchronisation model on the cubic-Hermite cable: a per-length lift k U (t x v_r) Gauss-integrated over each element with k = 1/2 rho D Cl cos(phi) interpolated between the nodes, exact Jacobians in q and v, the node phase sampled along the slope-DOF tangent, explicit predictor and Heun commit as on EI = 0 lines. Wired through the step, the recovering step, the snapshot, the end force and the node recovery, and installed by the standalone finite-EI deck march; the other routes refuse it. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
…ument finite-EI VIV (wip) Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
…ing (wip) Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
…wip) Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
…EI lock-in at a fine step (wip) Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
Codex Review SummaryThis comment shows the latest Codex review activity on this pull request.
ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
Codex reacts with 👀 while any review is running, comments if it has suggestions, and reacts with 👍 once all reviews finish with no findings. |
💡 Codex ReviewCableDyn/src/CableDyn_HermiteCableDynamic.f90 Line 1022 in 97993e0 If a caller invokes ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
The lift scale 1/2 rho D Cl and the node shedding diameter were set once from the drag configuration of the moment VIV was installed; a later CD_HermiteCable_Dyn_Set_Drag with another density or diameter left them behind (doubling the diameter kept the old lift and doubled the shedding frequency). The element Cl is now kept, and both are taken again from the drag whenever it is reconfigured, its rollback included. The Hermite VIV test reconfigures the drag both ways. viv_lockin runs its eight decks side by side and allows a checked Debug build 2400 s; it timed out at 600 s on the Debug CI jobs. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
Fixed in e3a9e9c: the element Cl is now kept, and the lift scale 1/2 rho D Cl and the node shedding diameter are recomputed from the drag whenever @codex review |
There was a problem hiding this comment.
💡 Codex Review
Here are some automated review suggestions for this pull request.
Reviewed commit: e3a9e9c821
ℹ️ About Codex in GitHub
Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you
- Open a pull request for review
- Mark a draft as ready
- Comment "@codex review".
If Codex has suggestions, it will comment; otherwise it will react with 👍.
Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".
CD_HermiteCable_Dyn_Set_VIV left the committed acceleration at its no-lift value, unlike the other load setters: installed on a model at rest in a cross current, the first step's phase rate and the generalised-alpha inertia took an acceleration without the lift, and removing VIV (all-zero Cl) kept the lift in it. The setter now solves the consistent acceleration after installing or removing the lift; if that fails, the previous VIV configuration, its phases and running mean squares, and the acceleration are restored. The Hermite VIV test checks that installing the lift moves the acceleration and removing it brings the no-lift value back. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
|
Codex Review: Didn't find any major issues. More of your lovely PRs please. Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
viv_lockin runs four driver processes at once but counted as one ctest job, so under ctest --parallel 4 it shared the four CI cores with three more tests: on the Windows Debug job attachment_cross_current, which overlapped it, went from about 190 s on dev to 572 s and then past its 600 s timeout. PROCESSORS 4 makes ctest run nothing beside it, as for the other tests that run their decks four at a time. Signed-off-by: Jae Hoon Seo <jaehoon.seo@inha.ac.kr>
|
@codex review |
|
Codex Review: Didn't find any major issues. Chef's kiss. Reviewed commit: ℹ️ About Codex in GitHubYour team has set up Codex to review pull requests in this repo. Reviews are triggered when you
If Codex has suggestions, it will comment; otherwise it will react with 👍. Codex can also answer questions or update the PR. Try commenting "@codex address that feedback". |
The cross-flow VIV synchronisation model of #55 now runs on finite-EI (cubic-Hermite) cables in
the standalone driver: the same LINE TYPES columns
ClorCl dF cFon anEI > 0type.Model. The lift is a distributed load per unit deformed length,
f = 1/2 rho d Cl cos(phi) U (t x v_r), with t the unit tangent of the centreline, v_r the
relative flow and cos(phi) interpolated linearly between the element's end nodes. It is
integrated against the Hermite shape functions at the drag element's three Gauss points (a
point above the surface carries none), with its exact position and velocity Jacobians in the
tangent (the residual path and the parallel tangent-only path). Each node carries a phase,
driven by the node's cross-flow motion along its own tangent, the slope degrees of freedom;
d, cF and dF at a node are the length-weighted averages over its lifting elements, and the
phases start at 2 pi i/N from End A. As on EI = 0 lines the phase is explicit: the step's
evaluations take the phase predicted from the step-start rate (at t_n+1 under the force blend,
whose committed force F_n keeps phi_n; at the generalised-alpha level under the configuration
blend), and the commit is the Heun update. With VIV the converged force is not cached as the
next step's F_n (it took the predicted phase).
No smoothing is needed: the Hermite tangent and the integrated lift leave no mesh-scale mode
for the synchronisation loop to pump.
State. The phases and running mean squares are saved and restored with the kinematics by the
recovering step, the snapshot and the deallocation; every evaluation outside a step (end
forces, node recovery, the held-field update, the committed acceleration) takes the committed
phase. The phase commit cannot fail, so a step is never left half committed: a node whose end
tangent is degenerate takes the step-start rate over the step. An internal wave family (Set_Waves) is refused on a VIV cable; deck waves and current
reach the standalone Hermite march as its held fluid field, which the phase follows.
Routes.
build_one_hermite_cableinstalls VIV only for the standalone finite-EI march. Afinite-EI line with two moving ends (compatibility route), a finite-EI line beside bodies, rods
or free points (multibody march), the single-cable
CD_Init_Deck_HermiteCableentry and theaggregate (coupled, mixed) route refuse
Cl > 0by name;DeckFilemirrors the refusals.Validation (VALIDATION.md L2-VIV-EI, gated in
viv_lockinandhermite_viv):0.662/0.421 against the EI = 0 line's 0.663/0.421 at the same frequency, unchanged at dtM
1e-2, 2e-3 and 5e-4 s;
against the EI = 0 string of equal first-mode frequency, tension T(1 + beta): the same
mode-1 lock-in (A/D within 2.5 %, same frequency) for U <= 0.24 m/s; for U >= 0.27 m/s the
string jumps to mode 2 while the cable stays in mode 1, its bending having raised f2/f1 to
about 3.15;
current) shows out-of-plane VIV at 0.47 Hz with the fairlead tension oscillating at twice
that frequency, and stays still without the lift.
Tests:
hermite_viv(the setter's refusals, the lock-in with and without lift, a mid-runsnapshot replaying the state and phase bit for bit, the recovering step equal to the plain
step),
viv_kernelssection 7 (the per-length lift and its flow and tangent Jacobians againstcentral differences),
viv_lockin(the two comparisons above, the EI = 1 cable at dtM 0.01 and0.002 s), and the deck-file tests. Full suite: 305/305 ctest, 2082 pytest; every shipped
example's output is byte-identical to dev.