1+
# Correlating RC Values for PDKs
2+
3+
## Background
4+
5+
This tutorial covers how to correlate platform RC values and generate updated RC values for setRC.tcl.
6+
7+
## What’s unit RC?
8+
Unit resistance (resistance per unit length) or unit capacitance (capacitance per unit square distance) are used to estimate wire delays during place and route flow when fully extracted parasitics are not available. For example, global router can use unit RC to estimate delays for wires.
9+
10+
Unit RC values can be defined in technology LEF, but many modern PDKs do not specify them. In some cases, the values that are specified are not accurate.
11+
12+
Inaccurate unit RC values can lead to inconsistent timing results between global route and detailed route.
13+
14+
## Flow usage
15+
Unit RC values per layer can be defined in OpenROAD-flow-scripts/flow/platforms/<PDKname>/setRC.tcl. For example, OpenROAD-flow-scripts/flow/platforms/asap7/setRC.tcl contains
16+
17+
```
18+
set_layer_rc -layer M1 -resistance 7.04175E-02 -capacitance 1e-10
19+
set_layer_rc -layer M2 -resistance 2.97126E-02 -capacitance 1.84542E-01
20+
set_layer_rc -layer M3 -resistance 3.12872E-02 -capacitance 1.53955E-01
21+
set_layer_rc -layer M4 -resistance 1.80365E-02 -capacitance 1.89434E-01
22+
set_layer_rc -layer M5 -resistance 1.89936E-02 -capacitance 1.71593E-01
23+
```
24+
25+
## Generating unit RC values from actual designs
26+
27+
Unit RC values can be extracted by completing P&R flow for relevant designs in ORFS up to detailed route and parasitic extraction. For example, to generate RC values for design ‘ibex’ in PDK asap7, do the following:
28+
29+
```
30+
% cd OpenROAD-flow-scripts/flow
31+
% make DESIGN_CONFIG=./designs/asap7/ibex/config.mk
32+
% make DESIGN_CONFIG=./designs/asap7/ibex/config.mk write_segment_rc
33+
```
34+
35+
This will generate a segment RC CSV file under results directory. For
36+
example, ./results/asap7/ibex/base/6_segment_rc.csv.
37+
38+
```
39+
% make DESIGN_CONFIG=./designs/asap7/ibex/config.mk correlate_rc
40+
```
41+
42+
This will print a setRC.tcl file content for one design like the following:
43+
44+
```
45+
set_layer_rc -layer M2 -resistance 2.97127E-02 -capacitance 1.74942E-04
46+
set_layer_rc -layer M3 -resistance 3.12870E-02 -capacitance 1.55554E-04
47+
set_layer_rc -layer M4 -resistance 1.80365E-02 -capacitance 1.78475E-04
48+
set_layer_rc -layer M5 -resistance 1.89935E-02 -capacitance 1.64264E-04
49+
set_layer_rc -layer M6 -resistance 1.18796E-02 -capacitance 1.87426E-04
50+
set_layer_rc -layer M7 -resistance 1.25096E-02 -capacitance 1.62979E-04
51+
set_layer_rc -layer M8 -resistance 8.44765E-03 -capacitance 1.03962E-04
52+
set_layer_rc -layer M9 -resistance 8.89556E-03 -capacitance 9.28446E-05
53+
54+
set_wire_rc -resistance 2.63040E-02 -capacitance 1.64745E-04
55+
set_wire_rc -signal -resistance 2.65684E-02 -capacitance 1.65790E-04
56+
set_wire_rc -clock -resistance 2.14161E-02 -capacitance 1.45426E-04
57+
```
58+
59+
Segment RC CSV files from multiple designs can be combined to produce one large segment RC CSV file. This combined CSV file can be used to produce average setRC.tcl that are relevant for two designs by using correlateRC.py utility. For example, to combine RC data from designs ‘ibex’ and ‘jpeg’ together and generate one setRC.tcl, do the following:
60+
61+
```
62+
% make DESIGN_CONFIG=./designs/asap7/ibex/config.mk
63+
% make DESIGN_CONFIG=./designs/asap7/ibex/config.mk write_segment_rc
64+
% make DESIGN_CONFIG=./designs/asap7/jpeg/config.mk
65+
% make DESIGN_CONFIG=./designs/asap7/jpeg/config.mk write_segment_rc
66+
% cat ./results/asap7/ibex/base/6_segment_rc.csv >> ./combined_csv
67+
% cat ./results/asap7/jpeg/base/6_segment_rc.csv >> ./combined_csv
68+
% ./util/correlateRC.py --mode segment combined_segment_rc.csv
69+
reading segment.csv
70+
71+
Units: resistance [kohm/um], capacitance [pf/um]
72+
73+
Layer | Res R² | Cap R²
74+
----------------------------------
75+
M2 | 1.0000 | 0.9608
76+
M3 | 1.0000 | 0.9632
77+
M4 | 1.0000 | 0.9609
78+
M5 | 1.0000 | 0.9286
79+
M6 | 1.0000 | 0.9471
80+
M7 | 1.0000 | 0.9368
81+
M8 | 1.0000 | 0.8563
82+
M9 | 1.0000 | 0.8304
83+
----------------------------------
84+
85+
set_layer_rc -layer M2 -resistance 2.97127E-02 -capacitance 1.74942E-04
86+
set_layer_rc -layer M3 -resistance 3.12870E-02 -capacitance 1.55554E-04
87+
set_layer_rc -layer M4 -resistance 1.80365E-02 -capacitance 1.78475E-04
88+
set_layer_rc -layer M5 -resistance 1.89935E-02 -capacitance 1.64264E-04
89+
set_layer_rc -layer M6 -resistance 1.18796E-02 -capacitance 1.87426E-04
90+
set_layer_rc -layer M7 -resistance 1.25096E-02 -capacitance 1.62979E-04
91+
set_layer_rc -layer M8 -resistance 8.44765E-03 -capacitance 1.03962E-04
92+
set_layer_rc -layer M9 -resistance 8.89556E-03 -capacitance 9.28446E-05
93+
94+
set_wire_rc -resistance 2.63040E-02 -capacitance 1.64745E-04
95+
set_wire_rc -signal -resistance 2.65684E-02 -capacitance 1.65790E-04
96+
set_wire_rc -clock -resistance 2.14161E-02 -capacitance 1.45426E-04
97+
```

0 commit comments

Comments
 (0)