@@ -175,6 +175,8 @@ Acquiring a Z-Stack
175
175
:align:center
176
176
:alt:Adjusting the stage position in **navigate**.
177
177
178
+
* If the microscope has more than one stage that can move in the Z direction, choose the stage that should perform the stack from :guilabel:`Z-Stack Device` before setting the start and end positions. This selected device is the primary Z-stack stage: :guilabel:`Start`, :guilabel:`End`, and :guilabel:`Step Size` are applied to this stage. Other stack-capable stages can be moved with fixed offsets from the primary Z-stack stage when their offset settings are enabled.
179
+
178
180
* Under the :guilabel:`Channels` tab, in :guilabel:`Stack Acquisition Settings (μm)` press :guilabel:`Set Start Pos/Foc`.
4. :guilabel:`Laser Cycling Settings` selects Per Stack or Per Z channel ordering.
79
+
4. :guilabel:`Z-Stack Device` selects the primary Z-stack stage. When multiple stages can move along the Z direction, this is the stage that steps through the planes of the stack.
80
+
5. :guilabel:`Focus Device` selects the focus stage that is ramped with the primary Z-stack stage when the start and end focus values differ.
81
+
6. Additional stack-device offset controls, when present, move secondary stack stages at fixed offsets from the primary Z-stack stage.
82
+
7. :guilabel:`Laser Cycling Settings` selects Per Stack or Per Z channel ordering.
Copy file name to clipboardExpand all lines: docs/source/02_user_guide/05_acquiring_data/01_acquiring_guide/01_acquiring_guide.rst
+2Lines changed: 2 additions & 0 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -52,6 +52,8 @@ Z-Stack Acquisition
52
52
53
53
This takes an image stack over the range and at the step size defined by the :ref:`stack acquisition settings <ui_stack_settings>` and optionally saves the stack to a file. The color channels will appear as in "Continuous Scan" and "Single Acquisition" if :guilabel:`Laser Cycling Settings` is set to "Per Z" in the stack acquisition settings. A single z-stack will be taken for each color channel, one channel at a time, if :guilabel:`Laser Cycling Settings` is set to "Per Stack".
54
54
55
+
If the microscope exposes multiple stages that can move along the Z direction, :guilabel:`Z-Stack Device` in the stack acquisition settings selects the primary Z-stack stage. This primary stage is the one that receives the Z-stack start, end, and step-size moves. The selected :guilabel:`Focus Device` can be ramped with it to maintain focus, and any secondary stack stages with enabled offsets follow the primary Z-stack position plus their configured offsets.
56
+
55
57
Z-Stack acquisition is implemented as the feature list below.