This guide explains the method-profile system used by the Peel Trace Evaluation for Soft Substrates workflow.
The method profile controls analysis-sensitive settings such as selected-window length, start offset, terminal exclusion, drift filtering, peak detection, and extrema requirements.
The manuscript-baseline profile is:
manuscript_baseline_v1
This profile is read-only and is intended to reproduce the manuscript-baseline analysis settings.
Use this profile when generating outputs intended to match the manuscript-baseline workflow.
The manuscript-baseline profile uses the following locked settings:
| Parameter | Locked value |
|---|---|
| start offset | 5.0 mm |
| window length | 25.0 mm |
| terminal exclusion | final 20% of displacement span |
| drift gate | abs(m) * Lwin / Fbar_win <= 0.25 |
| peak prominence | 0.003 × global maximum corrected force |
| minimum selected-window points | 10 |
| required peaks/troughs | ≥5 peaks and ≥5 troughs |
| break/drop proxy | post-window 0.10 × Fc, 1-point detection; final recorded displacement fallback if no drop is found |
| extrema-spread QC | advisory in manuscript baseline; optional hard fail only in modified mode |
The backend protects these settings through a locked method-profile hash.
Modified settings are allowed only for recovery, troubleshooting, or sensitivity analysis.
Modified outputs should be labeled as:
NON_MANUSCRIPT_MODIFIED
Modified outputs should not be mixed with manuscript-baseline outputs unless the modification is explicitly disclosed.
A modified profile may be useful when:
- a trace does not contain enough usable displacement for the 25 mm manuscript-baseline window;
- peak or trough extraction fails because the trace has weak or nonstandard oscillations;
- a sensitivity analysis is needed to test whether conclusions depend on analysis settings;
- the user is analyzing a different material system where the manuscript-baseline settings are not appropriate.
Modified profiles should not be used to optimize adhesive rankings.
User-created profiles can include:
profile_id;display_name;profile_note;- modified analysis settings;
- recovery or sensitivity-analysis rationale.
Saved user profiles are separate from the locked manuscript-baseline profile.
When reporting manuscript-baseline results, state that the read-only manuscript_baseline_v1 profile was used.
When reporting modified or sensitivity results, disclose:
- which setting was changed;
- why it was changed;
- whether the output is
NON_MANUSCRIPT_MODIFIED; - whether the change affects metric interpretation.
Changing analysis settings can change selected windows, extrema extraction, PSI, SSA, displacement proxies, and replicate summaries.
Therefore, profile changes should be treated as method changes, not cosmetic changes.