Configuration Examples

These examples are starting points for config.json or Docker config/config.json. The template profile is intended for normal standalone live control after real local values are configured and installation limits are reviewed.

If required placeholders are still present, EMS forces safe mode: control disabled, dry-run enabled, and hardware writes blocked. Set dry_run=true manually when you want an explicit no-write validation run after configuration.

Use example IP addresses and serial numbers as placeholders only. Before unattended operation, enter real grid meter and Zendure values, review power and SOC limits, confirm battery and PV metadata, run first-run-checklist.md, and monitor the first live run.

Example 1: One Zendure Device Without Home Assistant

Use this for standalone EMS operation without Home Assistant.

{
  "ha": {
    "enabled": false,
    "control_enabled": false,
    "url": "",
    "token": ""
  },

  "system": {
    "enabled": true,
    "dry_run": false,
    "simulation_mode": false,
    "allow_hardware_writes": true,
    "allow_state_reconciliation_writes": true,
    "reconcile_ac_mode_on_start": true,
    "reconcile_smart_mode": true,
    "log_level": "info",
    "max_total_power": 800,
    "max_device_power": 800,
    "deadband": 2,
    "runtime_state_path": "data/runtime-state.json",
    "min_output_limit": 35,
    "loop_interval": 5,
    "redistribute_clamped_power": true,
    "pv_kwp_weighting": true,
    "pv_charge_balance_enabled": true,
    "pv_charge_balance_deadband_percent": 1,
    "pv_charge_balance_full_bias_percent": 15,
    "pv_charge_balance_strength": 0.7,
    "battery_kwh_weighting": true,
    "soc_reconcile_interval": 10
  },

  "dashboard": {
    "enabled": true,
    "host": "0.0.0.0",
    "port": 8080,
    "database_path": "data/ems_dashboard.sqlite",
    "history_hours": 48,
    "write_interval_seconds": 5
  },

  "energy_savings": {
    "enabled": true,
    "price_per_kwh": 0.0,
    "currency": "EUR",
    "max_sample_delta_seconds": 20,
    "timezone": "Europe/Berlin"
  },

  "winter": {
    "enabled": false,
    "months": [10, 11, 12, 1, 2, 3],
    "summer_min_soc": 15,
    "winter_min_soc": 40,
    "ramp_step_percent": 5,
    "adjust_hour": 12,
    "ac_charge_power": 200
  },

  "devices": [
    {
      "name": "WR1",
      "ip": "192.168.1.100",
      "sn": "YOUR_SN",
      "smart_mode": 1,
      "max_power": 800,
      "pv_kwp": 1.0,
      "pv_priority_factor": 1.0,
      "battery_kwh": 1.0,
      "min_soc": 15,
      "max_soc": 100
    }
  ],

  "grid_meter": {
    "type": "shelly",
    "ip": "192.168.1.50"
  }
}

Change:

  • devices[0].ip
  • devices[0].sn
  • grid_meter.type, grid_meter.ip, and Shelly grid_meter.channels if needed
  • pv_kwp
  • battery_kwh
  • dashboard.port or dashboard.database_path only when needed
  • energy_savings.price_per_kwh
  • energy_savings.currency
  • energy_savings.timezone only when you do not want Europe/Berlin calendar days

Docker check:

docker compose exec ems python3 emsctl.py diagnose

Native Python validation:

python3 -B ems-solarflow-api-control.py --simulate --max-cycles 1
python3 -B ems-solarflow-api-control.py --preflight

Example 2: Two Zendure Devices With Home Assistant

Use this when Home Assistant should receive EMS sensors and optionally provide runtime helper controls. The values below intentionally override some single-device template values for a two-inverter installation.

{
  "ha": {
    "enabled": true,
    "control_enabled": true,
    "url": "http://homeassistant.local:8123",
    "token": "YOUR_TOKEN_HERE"
  },

  "system": {
    "enabled": true,
    "dry_run": false,
    "simulation_mode": false,
    "allow_hardware_writes": true,
    "allow_state_reconciliation_writes": true,
    "reconcile_ac_mode_on_start": true,
    "reconcile_smart_mode": true,
    "max_total_power": 1600,
    "max_device_power": 800,
    "runtime_state_path": "data/runtime-state.json",
    "min_output_limit": 35,
    "loop_interval": 5
  },

  "devices": [
    {
      "name": "WR1",
      "ip": "192.168.1.100",
      "sn": "YOUR_SN",
      "smart_mode": 1,
      "max_power": 800,
      "pv_kwp": 1.0,
      "pv_priority_factor": 1.0,
      "battery_kwh": 1.0,
      "min_soc": 15,
      "max_soc": 100
    },
    {
      "name": "WR2",
      "ip": "192.168.1.101",
      "sn": "YOUR_SN",
      "smart_mode": 1,
      "max_power": 800,
      "pv_kwp": 1.0,
      "pv_priority_factor": 1.0,
      "battery_kwh": 1.0,
      "min_soc": 15,
      "max_soc": 100
    }
  ],

  "grid_meter": {
    "type": "shelly",
    "ip": "192.168.1.50"
  }
}

Change:

  • ha.url
  • ha.token
  • both device IPs and serial numbers
  • grid_meter.type, grid_meter.ip, and Shelly grid_meter.channels if needed
  • PV and battery metadata

Docker check:

docker compose exec ems python3 emsctl.py diagnose

Native Python validation:

python3 -B ems-solarflow-api-control.py --preflight
python3 -B ems-solarflow-api-control.py --duration 120

Example 3: Safe Dry-Run Setup

This setup allows live telemetry reads and target calculation, but blocks Zendure hardware writes.

{
  "system": {
    "dry_run": true,
    "allow_hardware_writes": true,
    "allow_state_reconciliation_writes": true
  }
}

Docker check:

docker compose exec ems python3 emsctl.py diagnose

Native Python validation:

python3 -B ems-solarflow-api-control.py --preflight --dry-run
python3 -B ems-solarflow-api-control.py --dry-run --once

Example 4: Conservative Manual Safety Startup

Use this optional variant when you want to block all Zendure writes until after manual validation.

{
  "system": {
    "dry_run": true,
    "allow_hardware_writes": false,
    "allow_state_reconciliation_writes": false
  }
}

This is not the normal template profile. It blocks both normal outputLimit writes and state reconciliation writes until you change the flags back.

Docker check:

docker compose exec ems python3 emsctl.py diagnose

Native Python validation:

python3 -B ems-solarflow-api-control.py --preflight --dry-run
python3 -B ems-solarflow-api-control.py --dry-run --once

Example 5: Default Live Control Profile

This is the normal template policy for standalone operation after required placeholders are replaced, real local values are configured, and installation limits are reviewed.

{
  "system": {
    "dry_run": false,
    "allow_hardware_writes": true,
    "allow_state_reconciliation_writes": true,
    "reconcile_ac_mode_on_start": true,
    "reconcile_smart_mode": true
  }
}

This allows normal outputLimit writes and required regulation/state reconciliation. Runtime AC mode intent is evaluated during the control loop, but startup acMode reconciliation is conservative when telemetry is unknown. ac_output maps to acMode=2; ac_input maps to acMode=1 and blocks normal output regulation. An explicit runtime ac-mode output command can still write acMode=2 when the reported mode is 0.

Manual runtime AC charging uses the same loop-owned reconciliation path:

python3 emsctl.py device WR1 ac-charge-power 200
python3 emsctl.py device WR1 ac-mode input
python3 emsctl.py device WR1 ac-mode output

ac-charge-power stores ac_charge_power_w in runtime-state only. The controller applies it as inputLimit on the next EMS loop while the role is ac_input, and ignores it for hardware writes while the role is ac_output.

The defaults are intended to expose the main regulation features with minimal setup. They are not a universal safety profile; review device limits, SOC limits, grid meter readings, and installation-specific constraints for each installation.

Optional Battery Full-Charge Assist

The template enables EMS full-charge assist by default. Set enabled to false in config.json to opt out:

{
  "battery_full_charge_assist": {
    "enabled": true,
    "interval_days": 28,
    "assist_window_days": 7,
    "assist_start_soc": 80,
    "force_time": "14:00",
    "ac_charge_power": 200,
    "enable_ac_charge_mode": true,
    "state_database_path": "data/ems_state.sqlite"
  }
}

When enabled, EMS temporarily requests socSet=1000 and waits for firmware socLimit == 1. AC-assisted charging reuses the runtime AC intent path; EMS does not write firmware calibration properties.

Example 6: Tasmota HTTP Grid Meter

Use Tasmota HTTP when a Tasmota smart meter reader exposes current power in the Status 10 JSON response. power_path must match your local Tasmota JSON keys.

SML-style payload path:

{
  "grid_meter": {
    "type": "tasmota_http",
    "ip": "192.168.1.70",
    "power_path": "StatusSNS.SML.Power_curr"
  }
}

OBIS-style key path:

{
  "grid_meter": {
    "type": "tasmota_http",
    "url": "http://192.168.1.70/cm?cmnd=Status%2010",
    "power_path": "StatusSNS.SM.16_7_0"
  }
}

Positive power means grid import. Negative power means export/feed-in when the meter reports signed values that way.

Example 6b: Zendure Grid Meter via local HTTP (recommended)

Use zendure_grid_meter_http when a Zendure grid meter is reachable on the LAN. This is the recommended Zendure grid-meter connection and works for both a Zendure D0 and a Smart Meter 3CT: both expose a flat numeric total_power at the local REST endpoint http://<ip>/properties/report. No MQTT broker and no app MQTT configuration are required, and current known firmware serves the endpoint without authentication.

{
  "grid_meter": {
    "type": "zendure_grid_meter_http",
    "ip": "192.168.1.50"
  }
}

The discovered HTTP port is preserved (default 80). Numeric total_power is the functional read criterion, and its sign is used as reported by the device. The per-phase fields a_aprt_power, b_aprt_power, and c_aprt_power are not used to identify the model — a D0 reports the same fields — and meterType / protocolType are not treated as proven D0 identifiers. The Admin may show "Zendure Grid Meter via local HTTP" without claiming a specific model.

The older zendure_smartmeter_3ct_http type remains accepted as a backward-compatible alias for the same client, so existing configs keep working.

Example 7: Zendure SmartMeter D0 via MQTT (optional alternative)

Local HTTP (Example 6b) is preferred. Use Zendure SmartMeter D0 (MQTT) only as an optional alternative when the D0 already publishes signed totalPower to an existing broker. EMS subscribes as a client; it does not run a broker and never publishes or writes values back to the meter. Only one central grid meter may be active.

Preferred: reference a named broker profile with broker_ref so the connection (host, port, TLS, credentials) lives once in zendure_mqtt.brokers and the broker password is never duplicated into the grid_meter block:

{
  "grid_meter": {
    "type": "zendure_smartmeter_d0",
    "mqtt": {
      "broker_ref": "local_mqtt",
      "topic": "Zendure/sensor/YOUR_D0_SERIAL/totalPower",
      "payload_format": "number",
      "max_age_seconds": 15
    }
  },
  "zendure_mqtt": {
    "brokers": {
      "local_mqtt": {
        "enabled": true,
        "source": "local_mqtt",
        "host": "192.168.1.10",
        "port": 1883,
        "tls": false,
        "username": "YOUR_MQTT_USER",
        "password": "YOUR_MQTT_PASSWORD"
      }
    }
  }
}

The legacy inline form is still accepted so existing configs keep working:

{
  "grid_meter": {
    "type": "zendure_smartmeter_d0",
    "mqtt": {
      "host": "192.168.1.10",
      "port": 1883,
      "username": "YOUR_MQTT_USER",
      "password": "YOUR_MQTT_PASSWORD",
      "topic": "Zendure/sensor/YOUR_D0_SERIAL/totalPower",
      "payload_format": "number",
      "max_age_seconds": 15
    }
  }
}

Do not combine broker_ref with inline connection fields — that is rejected as ambiguous. TLS brokers are supported ("tls": true, and "tls_insecure": true only when you explicitly accept unverified certificates; it skips certificate-chain and hostname verification). A broker profile used for a D0 grid meter must have source: local_mqtt; Zendure Cloud MQTT D0 grid meters are not supported. Known D0 samples use positive values for grid import and negative values for grid export. This integration has unit-test and mocked MQTT coverage; live D0 hardware validation depends on external tester feedback.

Generic JSON MQTT payload example:

{
  "grid_meter": {
    "type": "mqtt",
    "mqtt": {
      "host": "192.168.1.10",
      "port": 1883,
      "topic": "meter/grid",
      "payload_format": "json",
      "value_path": "power.total",
      "max_age_seconds": 15
    }
  }
}

Example 8: Shelly Clamp/Phase Selection

Shelly uses em:0.total_act_power by default and falls back to summing em1:0, em1:1, and em1:2 act_power values when the aggregate is not available.

Use channels when only selected clamps should be summed. A single item list such as ["c"] is valid and reads only clamp C:

{
  "grid_meter": {
    "type": "shelly",
    "ip": "192.168.1.50",
    "channels": ["c"]
  }
}

Multiple items such as ["a", "c"] sum only those selected clamps:

{
  "grid_meter": {
    "type": "shelly",
    "ip": "192.168.1.50",
    "channels": ["a", "c"]
  }
}

channels entries may be a, b, c, em1:0, em1:1, or em1:2. The values total and sum are not valid inside channels.

Example 8b: Shelly 3EM Gen1 Grid Meter

The older non-Pro Shelly 3EM Gen1 meter uses the classic /status endpoint instead of /rpc/Shelly.GetStatus. Use the shelly_3em_gen1 type for it:

shelly            = Shelly Pro / Gen2 / Gen3 via /rpc/Shelly.GetStatus
shelly_3em_gen1   = Shelly 3EM Gen1 via /status

A Shelly 3EM Gen1 reads the top-level total_power by default, falling back to summing all three emeters[].power values:

{
  "grid_meter": {
    "type": "shelly_3em_gen1",
    "ip": "192.168.1.50"
  }
}

Use channels only when you intentionally want to read a subset of phases/clamps. Valid entries are a, b, c, 0, 1, 2, emeter:0, emeter:1, and emeter:2. Phase letters are normalized to lowercase, and when channels is configured total_power is ignored:

{
  "grid_meter": {
    "type": "shelly_3em_gen1",
    "ip": "192.168.1.50",
    "channels": ["a", "c"]
  }
}

Clamp direction must match EMS expectations: positive = grid import, negative = grid export. The sign is not inverted automatically.

Example 9: Runtime-State Explained

On first start, EMS creates the configured runtime-state file automatically. New generated configs use data/runtime-state.json.

Runtime-state contains operator values like:

  • system enabled
  • runtime max total power
  • runtime loop interval
  • runtime minimum output limit
  • device enabled
  • device runtime max power
  • device offgrid socket mode
  • device runtime PV priority factor
  • winter runtime toggle

Runtime state is temporary runtime data. Do not copy it into config.json or maintain it as a second static config.

Reset runtime values from config defaults:

rm data/runtime-state.json
python3 -B ems-solarflow-api-control.py --dry-run --once

Older root-level runtime-state.json files from previous setups are no longer required after switching to data/runtime-state.json and may be removed manually.

Use the CLI for safe runtime edits:

python3 emsctl.py status
python3 emsctl.py system min-output-limit 30
python3 emsctl.py device WR1 pv-priority-factor 1.3
python3 emsctl.py device WR1 offgrid eco
python3 emsctl.py winter enable

pv-priority-factor changes PV-first weighting only. It does not create additional PV power and does not override device power limits.

Example 10: Winter Mode Enabled

Winter mode is optional and runs as SOC reconciliation, not as normal output control.

{
  "winter": {
    "enabled": true,
    "months": [10, 11, 12, 1, 2, 3],
    "summer_min_soc": 15,
    "winter_min_soc": 40,
    "ramp_step_percent": 5,
    "adjust_hour": 12,
    "ac_charge_power": 200
  }
}

Winter SOC adjustments use the same state reconciliation gates that are enabled in the default live profile:

{
  "system": {
    "dry_run": false,
    "allow_hardware_writes": true,
    "allow_state_reconciliation_writes": true
  }
}

inputLimit is only used in the winter/SOC reconciliation context. Do not use winter mode as a per-cycle mode write mechanism.

Run first:

python3 -B ems-solarflow-api-control.py --dry-run --once

Example 11: Advanced Output Control Defaults

Most installations should keep these defaults. Change them only when the live logs show target oscillation, stale telemetry, or excessive write frequency.

The slower down-ramps (ramp_down_w_per_cycle, device_ramp_down_w_per_cycle) are intentional: they help prevent undershoot when the inverter output reacts more slowly than the EMS control target. The values below are the defaults for newly created configurations; an existing config.json keeps whatever it already sets (see Compatibility below).

{
  "system": {
    "output_control": {
      "load_deadband_w": 5,
      "target_deadband_w": 5,
      "filter_enabled": true,
      "filter_method": "median_ema",
      "median_window": 2,
      "ema_alpha": 0.85,
      "sign_change_fast_response_enabled": true,
      "sign_change_threshold_w": 50,
      "sign_change_filter_reset_factor": 1.0,
      "ramp_enabled": true,
      "ramp_up_w_per_cycle": 500,
      "ramp_down_w_per_cycle": 300,
      "device_ramp_enabled": true,
      "device_ramp_up_w_per_cycle": 400,
      "device_ramp_down_w_per_cycle": 200,
      "large_import_bypass_w": 600,
      "large_export_bypass_w": 600,
      "bypass_ramp_multiplier": 1.5,
      "telemetry_max_age_seconds": 10,
      "stale_telemetry_ramp_factor": 0.5
    }
  }
}

Validate after tuning:

python3 -B ems-solarflow-api-control.py --dry-run --duration 120

Compatibility note

The default values documented here apply only to newly created configurations (Fresh Install, and the config template). Loading an existing config.json never rewrites values you already set: an explicit loop_interval, deadband, or ramp value is always preserved. Missing keys are resolved by the normal config-upgrade and default-resolution policy — this is not a forced migration of running installations.