EMS controls real power hardware. Take a few minutes to check the points below before you let it run unattended.

Before enabling live writes

  • Check your inverter serial numbers.
  • Check inverter IP addresses.
  • Check your grid meter direction (import positive, export negative).
  • Check the maximum output limit.
  • Check minimum and maximum battery SOC.
  • Make sure no other controller writes Zendure output limits. Use only one active controller: disable Zendure HEMS, Smart Matching, Zendure schedules / energy plans, Home Assistant or ioBroker automations that set inverter power, and any second EMS instance. This matters especially for Zendure Cloud MQTT control — the cloud services write the same setpoints. The EMS cannot disable them for you; it reports external_control_suspected when a foreign writer repeatedly overrides a confirmed target.
  • Start with conservative settings.
  • Monitor the first live run.

Until your real values are filled in, EMS stays in safe mode: it calculates targets but does not write to hardware. Review your settings, then enable live writes.

Zendure Cloud MQTT control confirmation

Cloud MQTT control is only proven when the whole path checks out — a broker publish succeeding is not the same as the device applying the command. The EMS keeps these facts separate and honest:

  • Broker delivery is not device acceptance. broker_delivery=delivered (the QoS 1 PUBACK) only means the broker received the publish; a command is confirmed only when telemetry proves every commanded property (mode and setpoint) actually took effect and has trustworthy per-property time provenance. A matching cached value or a property with no observation time cannot confirm a command. Late PUBACK evidence is retained independently of newer commands within a bounded ledger. If an unresolved raw MQTT identifier becomes ambiguous across a disconnect, EMS quarantines it rather than ever attributing its callback to the wrong command.
  • A known model always writes to its canonical topic. A stale mqtt.write_topic left in an upgraded config can never misroute control; it is flagged and cleaned up by maintenance. Only the isolated custom escape hatch uses an explicit topic.
  • Validate before trusting it. To prove Cloud MQTT control end to end on real hardware, stop the EMS and use the hardware probe (developer/mqtt-write-latency-probe.md): it confirms the masked canonical topic shape, broker delivery, an exact setpoint match, the required mode properties, and a fully verified restore of every property the operation can modify. Restore verification also requires an observed post-command state transition before the complete initial state returns, so an unchanged read cannot hide a still-pending test command. The probe refuses the first write if any required initial value is missing and never substitutes a normal atomic power command for a partial restore. A read error during cleanup cannot skip the full restore attempt: the probe records the fault, keeps verification fail-closed, exits non-zero without sufficient evidence, and always stops the MQTT runtime it started. Do not conclude "Cloud MQTT control works" from movement toward the target or a broker PUBACK alone.

During the first live run

  • Watch grid power.
  • Watch inverter output.
  • Watch battery SOC.
  • Stop EMS if values look wrong.

The Admin Console dashboard and diagnostics make it easy to watch these values during the first run.

Backups before risky changes

Create a backup before updates, restore, config changes, or a reinstall. The Admin Console can create and restore backups for you — see Backup and restore.

Do not expose local control interfaces

EMS and the Admin Console are designed for trusted local networks. Do not expose the Admin Console — or the EMS ports — to the internet. Use them only on a trusted local network.

The Admin Console requires a password (the same one as the EMS Dashboard) before any setup, maintenance or backup action. This is a local safeguard, not a substitute for keeping the appliance off the public internet.

The Admin Console is intended for a trusted local network. Optional HTTPS can protect local browser traffic, but the generated self-signed certificate is not a replacement for a VPN or a properly secured reverse proxy for remote access.

Like the Dashboard, the Admin Console can write runtime overrides, but only for a fixed whitelist of keys (system power/loop limits, winter/HA enable, per-device enabled/max power/PV priority/off-grid mode) and only through the same validated runtime-write limits — never the hardware outputLimit or state-reconciliation write gates. The safety property is the whitelist, not the store: no other key can reach runtime-state.json from the Admin.

Technical safety model

For write gates, runtime write types, and control internals, see the technical safety model.