Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathems-solarflow-api-control.py
More file actions
531 lines (481 loc) · 17.4 KB
/
Copy pathems-solarflow-api-control.py
File metadata and controls
531 lines (481 loc) · 17.4 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
# SPDX-License-Identifier: AGPL-3.0-or-later
import argparse
import logging
import os
import sys
import time
from ems import config as cfg
from ems import paths
from ems.clients import (
HAClient,
ZendureClient,
close_grid_meter_client,
create_grid_meter_client,
create_session,
)
from ems.controller import EMSController
from ems.device_identity import broker_sources_from_config
from ems.logging_utils import log_event, setup_logging
from ems.runtime_state import RuntimeState, build_runtime_defaults
from ems.simulation import (
built_in_simulation_frames,
load_replay_frames,
run_frames,
run_live_preflight,
run_self_tests,
)
from ems.zendure_mqtt.config_entries import (
duplicate_device_name_startup_error,
duplicate_zendure_identity_startup_error,
)
# =====================
# CLI
# =====================
def parse_args():
parser = argparse.ArgumentParser(
description="Local Zendure SolarFlow EMS controller"
)
parser.add_argument(
"--dry-run",
action="store_true",
help="Read live telemetry and calculate targets without hardware writes"
)
parser.add_argument(
"--config",
help="Path to config file"
)
parser.add_argument(
"--no-ha",
action="store_true",
help="Disable Home Assistant reads and writes for this run"
)
parser.add_argument(
"--simulate",
action="store_true",
help="Run deterministic built-in simulation without hardware access"
)
parser.add_argument(
"--replay",
help="Replay a JSONL runtime trace without hardware access"
)
parser.add_argument(
"--once",
action="store_true",
help="Run one loop iteration and exit"
)
parser.add_argument(
"--duration",
type=float,
default=0,
help="Run for this many seconds and then exit"
)
parser.add_argument(
"--max-cycles",
type=int,
default=0,
help="Run for this many EMS cycles and then exit"
)
parser.add_argument(
"--preflight",
action="store_true",
help="Read telemetry and validate live-test prerequisites without control writes"
)
parser.add_argument(
"--self-test",
action="store_true",
help="Run local helper tests without hardware access"
)
return parser.parse_args()
def main():
args = parse_args()
base_dir = os.path.dirname(os.path.abspath(__file__))
cfg.initialize(args, base_dir)
setup_logging(cfg.LOG_LEVEL)
dashboard_enabled = cfg.safe_bool(cfg.DASHBOARD_CONFIG.get("enabled", False), False)
if dashboard_enabled:
# Install the in-memory log ring buffer right after logging is set up so
# the dashboard log viewer captures output from startup onward.
from ems.log_buffer import install_log_buffer
install_log_buffer(
capacity=cfg.safe_int(
cfg.DASHBOARD_CONFIG.get("log_buffer_lines", 5000),
5000,
minimum=1,
)
)
log_event(
logging.INFO,
"startup",
dry_run=cfg.DRY_RUN,
simulation=cfg.SIMULATION_MODE,
replay=bool(args.replay),
allow_hardware_writes=cfg.ALLOW_HARDWARE_WRITES,
allow_state_reconciliation_writes=cfg.ALLOW_STATE_RECONCILIATION_WRITES,
ha_enabled=cfg.HA_ENABLED,
ha_control_enabled=cfg.HA_CONTROL_ENABLED
)
if args.self_test:
sys.exit(0 if run_self_tests() else 2)
if cfg.SIMULATION_MODE and not args.replay:
run_frames(built_in_simulation_frames(), "built_in_simulation")
sys.exit(0)
if args.replay:
try:
replay_frames = load_replay_frames(args.replay)
except Exception as e:
log_event(
logging.ERROR,
"replay_load_error",
source=args.replay,
error=e
)
sys.exit(1)
run_frames(replay_frames, args.replay)
sys.exit(0)
# A physical Zendure device must be configured only once. Refuse to start
# rather than let two entries (e.g. an API device and an MQTT telemetry
# entry for the same serial) drive conflicting state.
duplicate_identity = duplicate_zendure_identity_startup_error(
cfg.CONFIG.get("devices"),
broker_sources=broker_sources_from_config(cfg.CONFIG),
)
if duplicate_identity:
log_event(
logging.ERROR,
"startup_abort",
reason="duplicate_zendure_device_identity",
**duplicate_identity,
)
sys.exit(1)
# Device names are the runtime identity key for controller state,
# runtime-state.json and history: two active devices sharing a name would
# silently merge, so refusing to start is the safe behavior.
duplicate_name = duplicate_device_name_startup_error(cfg.CONFIG.get("devices"))
if duplicate_name:
log_event(
logging.ERROR,
"startup_abort",
reason="duplicate_device_name",
**duplicate_name,
)
sys.exit(1)
session = create_session()
ha = None
if cfg.HA_ENABLED and not cfg.SIMULATION_MODE and not args.replay:
ha = HAClient(
cfg.HA_URL,
cfg.HA_TOKEN,
session
)
devices = [
ZendureClient(
d["name"],
d["ip"],
d["sn"],
session,
d.get("min_soc", 0),
d.get("max_soc", 0),
d.get("smart_mode", 1),
d.get("grid_off_mode"),
d.get("max_power", cfg.MAX_DEVICE_POWER),
d.get("pv_kwp", 1.0),
d.get("battery_kwh", 1.0),
d.get("pv_priority_factor", 1.0)
)
for d in cfg.http_control_device_configs()
]
# An unsafe, unmigrated MQTT control config must not be silently rewritten at
# startup: refuse to run the control runtime and point the operator at the
# EMS-owned migration (emsctl config migrate-zendure-mqtt). Telemetry-only and
# already-pinned control devices never block.
from ems.zendure_mqtt.migration import (
zendure_mqtt_control_migration_startup_error,
)
migration_required = zendure_mqtt_control_migration_startup_error(cfg.CONFIG)
if migration_required and not (
cfg.SIMULATION_MODE or args.replay
):
log_event(
logging.ERROR,
"startup_abort",
reason=migration_required["code"],
control_devices_needing_migration=migration_required["count"],
)
sys.exit(1)
# Write-capable Zendure MQTT devices join the same control loop as HTTP
# devices. Publishing is additionally guarded by the MQTT write gates.
zendure_mqtt_control_runtime = None
from ems.zendure_mqtt.control_runtime import (
MqttControlStartupError,
build_zendure_mqtt_control_runtime_or_abort,
)
try:
zendure_mqtt_control_runtime = build_zendure_mqtt_control_runtime_or_abort(
cfg.CONFIG
)
except MqttControlStartupError as e:
# MQTT control is configured but its runtime could not be built. Aborting
# is safer than silently running with fewer controllable inverters than
# configured.
log_event(
logging.ERROR,
"startup_abort",
reason="mqtt_control_runtime_build_failed",
error=e.__cause__ or e,
)
sys.exit(1)
if zendure_mqtt_control_runtime is not None:
accepted = len(zendure_mqtt_control_runtime.devices)
rejected = zendure_mqtt_control_runtime.rejected
configured = accepted + len(rejected)
# An enabled but invalid control device must not be silently skipped:
# starting with fewer controllable inverters than configured is unsafe.
if rejected:
codes = sorted(
{
issue["code"]
for entry in rejected
for issue in entry.issues
if issue.get("code")
}
)
log_event(
logging.ERROR,
"startup_abort",
reason="invalid_mqtt_control_device",
configured_control_devices=configured,
accepted_control_devices=accepted,
rejected_control_devices=len(rejected),
issue_codes=",".join(codes),
)
sys.exit(1)
if zendure_mqtt_control_runtime.devices:
zendure_mqtt_control_runtime.start()
devices = devices + zendure_mqtt_control_runtime.devices
log_event(
logging.INFO,
"zendure_mqtt_control_runtime",
configured_control_devices=configured,
accepted_control_devices=accepted,
rejected_control_devices=len(rejected),
)
if not devices:
log_event(logging.ERROR, "startup_abort", reason="no_devices")
sys.exit(1)
shelly = create_grid_meter_client(
cfg.GRID_METER_CONFIG,
session
)
runtime_state = RuntimeState(
cfg.runtime_state_path(),
build_runtime_defaults(devices)
)
runtime_state.load_or_create()
dashboard_store = None
if cfg.safe_bool(
cfg.DASHBOARD_CONFIG.get("enabled", False),
False
):
try:
from dashboard.server import start_dashboard_server
from dashboard.sqlite_store import DashboardStore
from dashboard.runtime_write import build_validation_context
from ems.log_buffer import get_log_buffer
dashboard_store = DashboardStore(
cfg.dashboard_database_path(),
retention_hours=cfg.safe_int(
cfg.DASHBOARD_CONFIG.get("history_hours", 48),
48,
minimum=1
),
energy_savings=cfg.ENERGY_SAVINGS_CONFIG
)
start_dashboard_server(
dashboard_store,
host=str(cfg.DASHBOARD_CONFIG.get("host", "0.0.0.0")),
port=cfg.safe_int(
cfg.DASHBOARD_CONFIG.get("port", 8080),
8080,
minimum=1
),
runtime_state=runtime_state,
auth_file=cfg.dashboard_file_path(
"auth_file",
"config/dashboard-auth.json"
),
ssl_enabled=cfg.safe_bool(
cfg.DASHBOARD_CONFIG.get("ssl_enabled", False),
False
),
ssl_cert_file=cfg.dashboard_file_path(
"ssl_cert_file",
"config/dashboard.crt"
),
ssl_key_file=cfg.dashboard_file_path(
"ssl_key_file",
"config/dashboard.key"
),
ssl_auto_generate=cfg.safe_bool(
cfg.DASHBOARD_CONFIG.get("ssl_auto_generate", True),
True
),
base_dir=base_dir,
config_path=cfg.config_path(),
runtime_state_path=cfg.runtime_state_path(),
log_buffer=get_log_buffer(),
log_redaction=cfg.safe_bool(
cfg.DASHBOARD_CONFIG.get("log_redaction", False),
False
),
animation_mode=str(
cfg.DASHBOARD_CONFIG.get("animation_mode", "normal")
),
session_timeout_seconds=cfg.safe_session_timeout(
cfg.DASHBOARD_CONFIG.get(
"session_idle_timeout_seconds", 1800
),
1800
),
session_absolute_max_seconds=cfg.safe_session_timeout(
cfg.DASHBOARD_CONFIG.get(
"session_absolute_max_seconds", 43200
),
43200
),
runtime_validation=build_validation_context(
cfg.CONFIG,
runtime_state
)
)
except Exception as e:
log_event(
logging.WARNING,
"dashboard_start_failed",
error=e
)
if args.preflight:
ok = run_live_preflight(devices, shelly, ha)
close_grid_meter_client(shelly)
sys.exit(0 if ok else 2)
# Native InfluxDB telemetry writer: active only when influxdb is enabled and
# we are reading real hardware (not simulation/replay). Started lazily and
# non-blocking; InfluxDB being unavailable never blocks or stops the EMS.
influx_writer = None
if (
cfg.INFLUXDB_CONFIG
and cfg.INFLUXDB_CONFIG.get("enabled")
and not cfg.SIMULATION_MODE
and not getattr(args, "replay", None)
):
try:
from ems.history.influx_writer import InfluxTelemetryWriter
influx_writer = InfluxTelemetryWriter(cfg.INFLUXDB_CONFIG)
influx_writer.start()
except Exception as e:
log_event(logging.WARNING, "influx_writer_start_failed", error=e)
influx_writer = None
# Zendure MQTT telemetry runtime. It reads snapshots and drives no writes;
# any control device shares its broker service so a broker used by both keeps
# a single connection and snapshot cache.
zendure_mqtt_runtime = None
zendure_mqtt_status_path = None
def _mqtt_control_status():
if zendure_mqtt_control_runtime is None:
return None
return zendure_mqtt_control_runtime.status()
try:
from ems.zendure_mqtt.runtime import build_zendure_mqtt_runtime
shared_services = (
zendure_mqtt_control_runtime.services_by_ref
if zendure_mqtt_control_runtime is not None
else None
)
zendure_mqtt_runtime = build_zendure_mqtt_runtime(
cfg.CONFIG, shared_services=shared_services
)
zendure_mqtt_runtime.start()
status = zendure_mqtt_runtime.status()
log_event(
logging.INFO,
"zendure_mqtt_runtime",
enabled=status["enabled"],
broker_configured=status["broker_configured"],
broker_count=status.get("broker_count", 0),
running=status["running"],
configured_devices=status["configured_device_count"],
invalid_devices=status["invalid_device_count"],
)
# Persist a live status snapshot Admin can prefer over its config-derived
# fallback. Read-only: no broker publish is involved. Control devices are
# merged in so they appear in runtime status too.
zendure_mqtt_status_path = paths.resolve_zendure_mqtt_status_path()
zendure_mqtt_runtime.write_status_file(
zendure_mqtt_status_path, control_status=_mqtt_control_status()
)
except Exception as e:
log_event(logging.WARNING, "zendure_mqtt_runtime_start_failed", error=e)
ems = EMSController(
devices,
shelly,
ha,
runtime_state=runtime_state,
dashboard_store=dashboard_store,
influx_writer=influx_writer,
zendure_mqtt_runtime=zendure_mqtt_runtime
)
log_event(logging.INFO, "ems_started")
start_time = time.time()
cycles = 0
try:
while True:
ems.run_once()
cycles += 1
# Self-heal: re-attempt broker connections that failed at boot.
# start() is idempotent, never raises on connection failure and
# throttles failed attempts internally.
if zendure_mqtt_control_runtime is not None:
zendure_mqtt_control_runtime.start()
if zendure_mqtt_runtime is not None:
zendure_mqtt_runtime.start()
if zendure_mqtt_runtime is not None and zendure_mqtt_status_path is not None:
zendure_mqtt_runtime.write_status_file(
zendure_mqtt_status_path, control_status=_mqtt_control_status()
)
if args.once:
log_event(
logging.INFO,
"ems_stopped",
reason="once",
cycles=cycles
)
break
if args.max_cycles and cycles >= args.max_cycles:
log_event(
logging.INFO,
"ems_stopped",
reason="max_cycles",
cycles=cycles
)
break
if args.duration and time.time() - start_time >= args.duration:
log_event(
logging.INFO,
"ems_stopped",
reason="duration",
cycles=cycles,
duration_s=round(time.time() - start_time, 1)
)
break
finally:
# Release the grid-meter client's runtime resources (the MQTT grid meter
# owns a network loop/connection/thread; HTTP clients own none). Safe and
# idempotent, and never masks a primary shutdown error.
close_grid_meter_client(shelly)
if influx_writer:
influx_writer.stop()
if zendure_mqtt_runtime is not None:
zendure_mqtt_runtime.stop()
if zendure_mqtt_control_runtime is not None:
zendure_mqtt_control_runtime.stop()
if __name__ == "__main__":
main()