Soliscloud Inverter Control Script

NO LONGER SUPPORTED - I found that dynamic scheduling was only delivering tiny savings, so I've moved back to a static schedule

A simple python class to interace with a Solis inverter via the Soliscloud Control API.

Issue tracking.


Warning: Use At Your Own Risk

As the license text makes clear, this code is provided "as is", with no warranty and no claim for fitness to purpose:

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

It bears repeating, because this script calls the Soliscloud Control API in order to write values into your inverter's registers.

Although the script does some validation (and the API hopefully does), it may be possible to write incorrect values which could damage your inverter (or even burn down your house).

Use of this software is entirely at your own risk and the author accepts no liability for the results of that use.


Config

The script takes configuration via environment variable:

Mandatory:

  • API_ID: Your soliscloud API key ID
  • API_SECRET: The secret for your API key
  • INVERTER_SERIAL: The serial number of your inverter (you can get this from the Soliscloud interface)

Optional:

  • DYNAMIC_SLOT: Which timing slot to use. Valid values are 1,2 or 3 (default 3)
  • RETRIES_ENABLED: Should the script retry (once) if Soliscloud returns a failure (default true)
  • RETRY_DELAY: Delay in seconds before retrying (default 3)
  • DEBUG: When true, prints additional information to stdout

Inverter Time Slots

Solis inverters have 6 timing slots within their registers, 3 each for charge and discharge.

The Soliscloud web interface won't allow you to configure overlapping/conflicting timeranges across slots. Their API, however, offers no such protection and it's not clear whether the inverter will hande this safely.

To be safe, before using this script you should remove any timeslots that you have configured (by setting them all to 00:00).

The script itself only uses a single timeslot.

Firmware Versions

Newer inverter firmware uses a different set of registers (providing 6 slots for each of charge and discharge rather than 3).

The script detects which is in use and adjusts accordingly, so no configuration is needed. DYNAMIC_SLOT remains 1-3 either way, and slots 4-6 (where present) are left untouched.

On newer firmware, charge and discharge current are configured per-slot rather than globally, so charge_current and discharge_current only affect the slot identified by DYNAMIC_SLOT.

Newer firmware also gives every field its own register, so configuring a single start or stop needs more API calls. The upstream API enforces rate-limits, so calls can take noticeably longer to return than they do on older firmware.

To mitigate the risk of a failure part way through the call, the utility sets things in the following order:

  • Disabling existing schedule
  • Setting charge/discharge current
  • Setting new schedule
  • Arming the schedule

This should mean that the failure mode is the battery not charging, rather than charging at the wrong time.


Control Server

This repo also contains a Dockerfile for an example control server, allowing HTTP API calls to be made in order to trigger functions without the client having to implement Solis's authentication mechanism.

The server uses HTTP Basic Authentication by default, so you should set a password in environment variable PASS (if you don't, it'll generate a random password for you):

docker run \
-d \
--restart=always \
--name soliscloudcontrol \
-e API_ID=$SOLIS_API_KEY_ID \
-e API_SECRET=$SOLIS_API_KEY_SECRET \
-e INVERTER_SERIAL=$INVERTER_SERIAL_NUMBER \
-e DO_AUTH=true \
-e USER=solisuser \
-e PASS=$LOCAL_API_PASS \
-p 8081:8080 \
ghcr.io/bentasker/soliscloud-inverter-control:weekly

Or if you prefer docker compose

version: '3'

services:
  soliscloudcontrol:
    image: ghcr.io/bentasker/soliscloud-inverter-control:0.1
    container_name: soliscloudcontrol
    restart: always
    environment:
      - API_ID=${SOLIS_API_KEY_ID}
      - API_SECRET=${SOLIS_API_KEY_SECRET}
      - INVERTER_SERIAL=${INVERTER_SERIAL_NUMBER}
      - DO_AUTH=true
      - USER=solisuser
      - PASS=${LOCAL_API_PASS}
    ports:
      - 8081:8080

API

The API only has a few endpoints, allowing charging and discharging to be started and stopped.

Endpoints

POST /api/v1/setCurrent

Set the charge and/or (forced) discharge current.

Expects a JSON payload with charge_current and/or discharge_current attributes.

See below for details on the JSON payload.

POST /api/v1/startCharge

Switch to charge mode immediately.

Optionally accepts a JSON request body, see below.

If no JSON request body is present, or it lacks an end attribute, the end time will be set 3 hours in the future.

POST /api/v1/startDischarge

Start a forced discharge immediately.

Optionally accepts a JSON request body, see below.

If no JSON request body is present, or it lacks an end attribute, the end time will be set 3 hours in the future.

POST /api/v1/stopCharge

Stop the charge and or discharge. Works by zeroing out the schedule that the script interacts with.

Optionally accepts a JSON request body, allowing charge rates to be set whilst stopping current charge.

POST /api/v1/stopDischarge

Stop the charge and or discharge. Works by zeroing out the schedule that the script interacts with.

Optionally accepts a JSON request body, allowing charge rates to be set whilst stopping current charge.


JSON payload

The control server endpoints accept an optional JSON request body:

{
  "end": "2025-01-02 14:30:00+0000",
  "charge_current": 30,
  "discharge_current": 55
}

Each of the attributes is optional

  • end: when to configure the inverter to end the charge/discharge period. The inverter uses a simple clock, so if this is beyond midnight it'll be converted to midnight. Only consumed by the start* endpoints
  • charge_current: current to use when charging. Consumed by start*, stop* and setCurrent endpoints
  • discharge_current: current to use when force discharging