Optional PCB:

The Optional PCB connects to the HP via the CN-CNT connector. If a CZ-TAW1 is also used, the wiring chain is HP → Optional PCB → CZ-TAW1: the Optional PCB connects directly to the HP's CN-CNT, and has its own CN-CNT connector for the CZ-TAW1 to connect to. The Optional PCB communicates with the HP in a similar way to the CZ-TAW1: alongside the standard Magic Packets, the Optional PCB sends its own specific commands to the HP, and alongside the HP's normal answers there is an additional answer/confirmation addressed to the Optional PCB.

Optional PCB emulation support:

Recent firmware allows (experimental) support for optional PCB emulation. This lets you set SmartGrid or Demand Control values without having the optional PCB installed, and lets you send the temperatures normally connected to that board to the heat pump.

You can publish MQTT messages to 'topic base/commands/pcb_topic', for example "panasonic_heat_pump/commands/SetSolarTemp". For temperatures, just send the real temperature — the hexadecimal value is calculated for you. For SmartGrid and Demand Control, send the decimal representation of the hex value you want to send (see below for the possible hex values).

Before enabling optional PCB emulation, be aware of the following:

Remark 1: You need to set Optional PCB to YES in the HP's service settings, along with the appropriate function, for the MQTT topics to have any effect.

Remark 2: Setting Optional PCB to YES gives HeishaMon (as the Optional PCB emulator) an obligation to continuously send the Optional PCB Set Command. If that communication stops for around 40 seconds, the HP raises an H74 error and switches to standby. Continuous communication is therefore essential — be careful during a HeishaMon reboot, factory reset, or similar action.

Remark 3: With optional PCB emulation enabled, HeishaMon will not boot into a WiFi config hotspot if it fails to connect to the configured WiFi at boot. It will also keep running and retry the WiFi connection on failure instead of rebooting into hotspot config mode — because it needs to keep sending optional PCB commands to the heat pump, it can't afford to react to WiFi failures the normal way. As a result, if HeishaMon is running and you need to reconfigure its WiFi SSID or password, you must first factory reset it (or, if a normal factory reset isn't possible in that situation, use the double-reset trick to clear its configuration).

Remark 4: Enabling Optional PCB in the HP's options disables the Room Thermo 1 input (H/J series only). The PCB topics "SetExternalThermostat1State" and "SetExternalThermostat2State" can be used as a replacement, with SetExternalThermostat1State taking over Room Thermo 1's role.

Set command byte decrypt:

PCB Topic Topic value Byte# Possible Value Value decrypt Value Description
- 00 F1 Header
- 01 11 Data length ( Packet length = Data length + 3 ) Header
- 02 01 Header
- 03 50 Header
- 04 00 Acknowledge for Z1/Z2/Pool Water Pump & Mixing valves state
- 05 00 Acknowledge for Alarm
SetHeatCoolMode
SetCompressorState
SetSmartGridMode
SetExternalThermostat1State
SetExternalThermostat2State
0/1
0/1
0/1/2/3
0/1/2/3
0/1/2/3
06 40 1st bit = Heat/Cool
2nd bit = Compressor state
3rd/4th bit == SmartGrid Mode (00 = normal, 10 = HP/DHW off, 01 = Capacity 1, 11 = Capacity 2)
5th/6th bit = Thermostat 1 (00 = no demand, 01 = cool demand, 10 = heat demand, 11 = heat and cool demand)
7th/8th bit = Thermostat 2 (00 = no demand, 01 = cool demand, 10 = heat demand, 11 = heat and cool demand)
SG ready values , External Compressor SW , Heat/Cool SW, Thermostat 1 (H/J series only), Thermostat 2
SetPoolTemp Temp [C] 07 FF NTC 6,5kOhm resistance characteristic value Temp. Pool
SetBufferTemp Temp [C] 08 FF NTC 6,5kOhm resistance characteristic value Temp. Buffer
(H/J series only)
- 09 E5 but also93,92,91 (90) ,A2 ?
SetZ1RoomTemp Temp [C] 10 FF NTC 6,5kOhm resistance characteristic value Temp. Z1_Room
(H/J series only)
SetZ2RoomTemp Temp [C] 11 FF NTC 6,5kOhm resistance characteristic value Temp. Z2_Room
- 12 00 0 byte
SetSolarTemp Temp [C] 13 FF NTC 6,5kOhm resistance characteristic value Temp. Solar
SetDemandControl from
43 -5%
to
234 - 100%
14 EA HEX: EB-100% ,B8 - 75% ,85 -50%,52 - 25% ,2B - 5% Demand Control
SetZ2WaterTemp Temp [C] 15 FF NTC 6,5kOhm resistance characteristic value Temp. Z2_Water
SetZ1WaterTemp Temp [C] 16 FF NTC 6,5kOhm resistance characteristic value Temp. Z1_Water
- 17 00 0 byte
- 18 00 0 byte
- 19 2C CHECKSUM

Answer/confirmation from HP to Optional PCB

Answer/confirmation contains also steering parameters :

71 11 01 50 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 2D

Byte# Possible Value Value decrypt Value Description
04 C4 1st bit = Z1 Water pump
2nd bit = Z1 Mixing Valve +
3rd bit = Z1 Mixing Valve -
4th bit = Z2 Water pump
5th bit = Z2 Mixing Valve +
6th bit = Z2 Mixing Valve -
7th bit = Pool Water pump
8th bit = Solar Water pump
05 01 00 - No Alarm
01 - Alarm

NTC 6,5kOhm characteristic:

Values are direct measurement of NTC thermistor conected to Optional PCB. It can be approximate by function : Uref * (RT / (Rf + RT)) where Uref = 255 and Rf=6480. RT is calculated as R25 * exp(constant * (1 / (temp + K) - 1 / (T25 + K))) where R25 = 6340, T25=25, K=273.15, constant=3695 and temp the input temperature.

Exact values table

HEX Val. Temp [C] HEX Val. Temp [C] Hex Val. Temp [C] Hex Val. Temp [C]
00 120 40 53 80 24 C0 0
01 120 41 53 81 24 C1 0
02 120 42 52 82 24 C2 -1
03 120 43 51 83 23 C3 -1
04 120 44 51 84 23 C4 -2
05 120 45 50 85 22 C5 -2
06 120 46 50 86 22 C6 -3
07 120 47 49 87 22 C7 -3
08 120 48 49 88 21 C8 -4
09 120 49 48 89 21 C9 -4
0A 120 4A 48 8A 21 CA -4
0B 120 4B 47 8B 20 CB -5
0C 117 4C 47 8C 20 CC -5
0D 114 4D 46 8D 19 CD -6
0E 111 4E 45 8E 19 CE -6
0F 108 4F 45 8F 19 CF -7
10 106 50 44 90 18 D0 -7
11 103 51 44 91 18 D1 -8
12 101 52 44 92 18 D2 -8
13 99 53 43 93 17 D3 -9
14 97 54 43 94 17 D4 -9
15 95 55 42 95 17 D5 -10
16 93 56 42 96 16 D6 -10
17 92 57 41 97 16 D7 -11
18 90 58 41 98 15 D8 -12
19 88 59 40 99 15 D9 -12
1A 87 5A 40 9A 15 DA -13
1B 86 5B 39 9B 14 DB -13
1C 84 5C 39 9C 14 DC -14
1D 83 5D 38 9D 14 DD -15
1E 82 5E 38 9E 13 DE -15
1F 80 5F 38 9F 13 DF -16
20 79 60 37 A0 12 E0 -16
21 78 61 37 A1 12 E1 -17
22 77 62 36 A2 12 E2 -18
23 76 63 36 A3 11 E3 -18
24 75 64 35 A4 11 E4 -19
25 74 65 35 A5 11 E5 -20
26 73 66 35 A6 10 E6 -21
27 72 67 34 A7 10 E7 -21
28 71 68 34 A8 9 E8 -22
29 70 69 33 A9 9 E9 -23
2A 69 6A 33 AA 9 EA -24
2B 68 6B 32 AB 8 EB -25
2C 67 6C 32 AC 8 EC -26
2D 66 6D 32 AD 8 ED -27
2E 66 6E 31 AE 7 EE -28
2F 65 6F 31 AF 7 EF -29
30 64 70 30 B0 6 F0 -30
31 63 71 30 B1 6 F1 -31
32 62 72 30 B2 6 F2 -32
33 62 73 29 B3 5 F3 -33
34 61 74 29 B4 5 F4 -35
35 60 75 28 B5 4 F5 -36
36 60 76 28 B6 4 F6 -38
37 59 77 28 B7 4 F7 -40
38 58 78 27 B8 3 F8 -41
39 58 79 27 B9 3 F9 -44
3A 57 7A 27 BA 2 FA -46
3B 56 7B 26 BB 2 FB -49
3C 56 7C 26 BC 2 FC -53
3D 55 7D 25 BD 1 FD -57
3E 54 7E 25 BE 1 FE -64
3F 54 7F 25 BF 0 FF -78

To do:

  • Byte #9 decode ( probably connected with Buffer)