Home Assistant integration for the LG ThermaV R290 monobloc heat pump, using Home Assistant's shared Modbus connection (requires 2026.9+). Successor to ha-lg-thermav-r290.

Resources

Stars

2 stars

Watchers

0 watching

Forks

Repository files navigation

LG ThermaV R290 — Home Assistant Integration

LG ThermaV R290

HACS custom integration for the LG ThermaV R290 heat pump via Modbus TCP or RTU.

Replaces a hand-crafted YAML Modbus configuration with native HA entities: sensors, binary sensors, switches, buttons, number inputs, and select dropdowns — all updated on every poll cycle without requiring template sensors or automations.


Features

  • Sensors — temperatures (inlet, outlet, DHW, outdoor, refrigerant circuit), flow rate, pressures, compressor speed, error code, operation mode, control method, energy state
  • Computed thermal power sensors — total / heating circuit / DHW, calculated from flow rate and ΔT each poll cycle (Q = flow/60 × ΔT × 4186 W)
  • Binary sensors — compressor, pumps, DHW heating, defrost, backup heater stages, fault, silent mode, cooling, emergency modes, energy state slots 0–8
  • Switches — main power, DHW, silent mode, emergency stop
  • Buttons — start DHW disinfection (momentary trigger coil)
  • Number inputs — flow temperature setpoints (circuit 1, circuit 2), DHW target temperature, heating curve shift values (circuit 1, circuit 2)
  • Select inputs — operation mode (Heating / Cooling / Auto), control method (outlet temp / inlet temp / room air)
  • Supports Modbus TCP, Modbus TCP-RTU, and Modbus RTU (serial)
  • Configurable poll interval (default 30 s), reconfigurable without restart
  • Shares one Modbus connection with every other integration on the same gateway

Coming from basti242's YAML setup?

Entity translation table: every entity of basti242/homeassistant_lg_therma_v_modbus next to its counterpart here, including the differences that matter when switching (inverted water-flow bit, missing write entities).


Experimental registers

The device answers on 18 registers that the manual does not list (a read-only scan on 2026-10-03, R290 9 kW):

Type Registers
Input 30015, 30018, 30064
Holding 40011–40023, 40063, 40064

Nothing in the manual or in the community projects I could find explains them. To find out what they are, the integration can record them over a longer time.

Switch it on under Settings → Devices & Services → LG ThermaV R290 → Configure → Experimental registers. This adds 18 diagnostic sensors named Experimental Input 30015, Experimental Holding 40011, … They carry the raw, unscaled 16-bit value and have long-term statistics, so they can be compared with compressor speed, temperatures and defrost cycles. Switching the option off removes them again.

They are read-only. The integration only ever writes a fixed list of known addresses (holding 0, 1, 2, 4, 5, 7, 8 and coils 0–4); every other write is refused before it reaches the bus, so none of these registers can be written by the integration, whichever entity or service asks. A register that stops answering leaves its sensor empty and does not affect the other values.

The full result of the scan, what the manual lists and what it does not, is in docs/register-scan.md.

Please tell me what you see, in particular if the values move with the compressor. A first reading from my unit: input 30015 reads 64887 (−64.9 °C as a signed tenth, the pattern of a temperature channel without a sensor), input 30018 reads 12000, and all of holding 40011–40023 read 0.


Requirements

Home Assistant 2026.9.0 or newer. From version 1.0.0 the integration no longer speaks to the bus itself. It asks Home Assistant's modbus component for a unit on a shared connection, which means:

  • Every integration pointing at the same gateway with the same link settings ends up on one connection, and their requests serialize behind its lock. This matters on RS485, where the line can only carry one conversation at a time: two clients with two sockets onto one gateway interleave their requests and provoke transaction-id mismatches and framing errors that hit both of them.
  • The Modbus stack is Home Assistant's own (modbus-connection on the tmodbus backend), so nothing is installed into the container on our behalf. The requirements list in the manifest is empty.
  • The same device may not be claimed twice with different link settings — plain TCP and RTU-over-TCP on one socket, say. The config flow reports that as an error rather than silently reframing.

Installation via HACS

  1. In HACS → Integrations → ⋮ → Custom repositories, add https://github.com/cjungde/ha-lg-thermav-modbus with category Integration.
  2. Install "LG ThermaV R290".
  3. Restart Home Assistant.
  4. Settings → Devices & Services → Add Integration → search "LG ThermaV R290".

Manual installation

Copy the custom_components/lg_thermav_r290/ folder into your HA custom_components/ directory and restart.


Configuration

The config flow asks for connection type first, then connection-specific parameters:

Parameter Default Notes
Connection type — TCP / TCP-RTU / RTU
Host / IP — TCP only
Port 502 TCP only
Serial port — RTU only (e.g. /dev/ttyUSB0)
Baudrate 9600 RTU only
Parity N RTU only
Stop bits 1 RTU only
Slave ID 1 1–247
Poll interval 30 s Adjustable in Options

Entities

Sensors

Entity Description Unit
sensor.lg_thermav_r290_inlet_temperature Inlet water temperature °C
sensor.lg_thermav_r290_outlet_temperature Outlet water temperature °C
sensor.lg_thermav_r290_dhw_temperature DHW tank temperature °C
sensor.lg_thermav_r290_outdoor_temperature Outdoor air temperature °C
sensor.lg_thermav_r290_backup_heater_outlet_temperature Backup heater outlet temp °C
sensor.lg_thermav_r290_flow_temperature_circuit_2 Flow temperature circuit 2 °C
sensor.lg_thermav_r290_flow_rate Water flow rate l/min
sensor.lg_thermav_r290_water_pressure Water pressure bar
sensor.lg_thermav_r290_high_pressure_condenser High pressure (condenser) bar
sensor.lg_thermav_r290_low_pressure_evaporator Low pressure (evaporator) bar
sensor.lg_thermav_r290_compressor_speed Compressor speed rpm
sensor.lg_thermav_r290_error_code Error code —
sensor.lg_thermav_r290_thermal_power_total Total thermal power output W
sensor.lg_thermav_r290_thermal_power_heating_circuit Heating circuit thermal power W
sensor.lg_thermav_r290_thermal_power_dhw DHW thermal power W
sensor.lg_thermav_r290_operation_mode Operation mode (label) —
sensor.lg_thermav_r290_control_method Control method (label) —
sensor.lg_thermav_r290_energy_state Energy state (label) —

Binary sensors

Entity Description
binary_sensor.lg_thermav_r290_compressor Compressor running
binary_sensor.lg_thermav_r290_water_pump Water pump running
binary_sensor.lg_thermav_r290_external_water_pump External water pump
binary_sensor.lg_thermav_r290_dhw_heating DHW heating active
binary_sensor.lg_thermav_r290_defrost Defrost active
binary_sensor.lg_thermav_r290_dhw_disinfection DHW disinfection
binary_sensor.lg_thermav_r290_backup_heater_step_1 Backup heater step 1
binary_sensor.lg_thermav_r290_backup_heater_step_2 Backup heater step 2
binary_sensor.lg_thermav_r290_dhw_boost_heater DHW boost heater
binary_sensor.lg_thermav_r290_fault Fault active
binary_sensor.lg_thermav_r290_silent_mode Silent mode
binary_sensor.lg_thermav_r290_cooling_active Cooling active
binary_sensor.lg_thermav_r290_water_flow Water flow present (see note below)
binary_sensor.lg_thermav_r290_energy_state_normal_operation Energy state: normal (value 2)
… Energy states 0–8 as individual binary sensors

Note on discrete input 10001 (water flow). The LG manual documents this bit as 0 = flow rate OK / 1 = flow rate too low. On the R290 monoblock it behaves the other way round: the bit is set while water is flowing. Measured on 2026-08-18 — di[0] = 0 at 5.0 LPM with the pump off, di[0] = 1 at 15.3 and 29.5 LPM with the pump running, with di[0] and di[1] (pump) identical in every sample of the same poll. A read offset is ruled out, since di[3] (compressor) and di[5] (DHW heating) stay correctly aligned.

The entity is therefore exposed as binary_sensor.lg_thermav_r290_water_flow with device class running. Exposing it as a problem sensor (as the manual suggests) would raise a false problem alert on every pump run.

Note on discrete input 10009 (cooling status). The R290 manual (p. 158, Diskretes Register 0x02) documents this bit as 0 = no cooling / 1 = cooling operation. On this unit the bit is set while the heat pump is heating. Measured on 2026-09-24: di[8] = 1 with the compressor running, flow 37.8 °C above return 35.7 °C and 3487 W going into the heating circuit, operation mode Auto, no cooling anywhere in the system.

A read offset is ruled out. di[1]/di[2] tracked a 3-minute-on / 15-minute-off pump cycle correctly to the second, di[3] (compressor) is consistent over days, and di[13]–di[16] match the R290 manual exactly (10014 fault, 10015 emergency space heating, 10016 emergency DHW, 10017 mix pump). Note that the memory map of other Therma V models differs here — on the HN1600MC, 10014 is Emergency Operation Available (DHW). Use the R290 manual, not a generic Therma V one.

The bit does not correlate with compressor state either: it stayed on continuously from 2026-09-21 22:03 to 2026-09-24 07:02 while the unit started and stopped repeatedly. What it actually reports on this model is unknown.

The entity binary_sensor.lg_thermav_r290_cooling_active is therefore not usable for diagnostics on the R290 monoblock. It is left in place because the register is read anyway and the mapping follows the manual — but do not build automations on it.

This is the second discrete input on this model that departs from the manufacturer's description, after 10001 above.

Switches

Entity Modbus coil
switch.lg_thermav_r290_heat_pump Coil 0
switch.lg_thermav_r290_dhw Coil 1
switch.lg_thermav_r290_silent_mode Coil 2
switch.lg_thermav_r290_emergency_stop Coil 4

Buttons

Coil 3 is a momentary trigger, not a state switch. The manual specifies it as 0: hold status / 1: start operation — the unit clears the coil by itself after the write, so reading it back is never a confirmation. Use the binary sensor to see whether the operation actually started.

Entity Modbus coil Status entity
button.lg_thermav_r290_start_disinfection Coil 3 (trigger) binary_sensor.lg_thermav_r290_dhw_disinfection (discrete 6)

A trigger coil modelled as a switch would always read back off, even when the write succeeded, which is why this is a button. Note that the trigger only has an effect if disinfection is enabled on the unit itself (installer menu → DHW → disinfection active; factory default is off).

Number inputs

Entity Range Holding register
number.lg_thermav_r290_target_temperature_circuit_1_radiators 30–50 °C 2 (×0.1)
number.lg_thermav_r290_target_temperature_circuit_2_underfloor 20–40 °C 5 (×0.1)
number.lg_thermav_r290_dhw_target_temperature 35–60 °C 8 (×0.1)
number.lg_thermav_r290_setpoint_shift_circuit_1 −5…+5 K 4 (signed)
number.lg_thermav_r290_setpoint_shift_circuit_2 −5…+5 K 7 (signed)

Select inputs

Entity Options Holding register
select.lg_thermav_r290_operation_mode Heating / Cooling / Auto 0
select.lg_thermav_r290_control_method Outlet / Inlet Water Temp Control / Room Air Control 1

Modbus register map (summary)

FC Address range Content
FC04 (input) 0–24 Temperatures, flow, pressures, compressor speed, error code
FC04 (input) 9997–9998 Product info, device group
FC03 (holding) 0–9 Operation mode, control method, setpoints, shift values, energy state
FC01 (coils) 0–4 Main switch, DHW, silent mode, disinfection trigger, emergency stop
FC02 (discrete) 0–16 Status bits (compressor, pumps, defrost, faults, …)

Notes

  • Thermal power formula: Q [W] = (flow_rate [l/min] / 60) × (outlet_temp − inlet_temp) [K] × 4186 [J/(l·K)]
  • Heating circuit / DHW split is based on the di_dhw_heating discrete input; when DHW is active the full flow is attributed to DHW and the heating circuit sensor reports 0, and vice versa.
  • Shift values (holding regs 4, 7) are stored as two's-complement uint16; values ≥ 32768 are interpreted as negative.
  • Tested on LG ThermaV R290 9 kW via Modbus TCP, slave ID 33.
  • tools/make_shadow.py builds a read-only copy of the integration under a second domain so a change to the Modbus layer can be measured against the running one on the same hardware. See tools/README.md.

License

MIT