* Guard against GRID_EXPORT as timed-export restore mode (#26)
If the inverter is already in GRID_EXPORT when a new timed export starts
(e.g. due to a stale duplicate scheduler instance), saving GRID_EXPORT as
the restore mode would leave the inverter exporting indefinitely with no
SOC floor protection after the timed window ends. Extend the existing
TOU→SELF_POWERED redirect to also cover GRID_EXPORT→SELF_POWERED.
* Add high_soc_export_set flag to prevent mid-period safety export oscillation (#27)
The mid-period high-SOC safety export had no one-shot guard — unlike the
clipping check (gated by clipping_export_set), it evaluated every tick.
Once an export ended at the SOC floor, solar would recharge past the 50%
trigger threshold and it would fire again after the 15-minute cooldown,
causing repeated export/restore cycles within the same period.
Add high_soc_export_set (same pattern as clipping_export_set) to
DayStateEntry. Once a mid-period high-SOC export fires, the flag prevents
re-triggering for the rest of that period. Auto-extension in
maybe_restore_timed_grid_export handles continuous strong solar during the
active window.
* Set 10% gap for mid-period high-SOC safety export (trigger 55%, floor 45%) (#27)
Raise trigger threshold from 50% to 55% and use DAYTIME_TIMED_EXPORT_MIN_SOC_PERCENT
(45%) as the SOC floor directly, replacing the headroom-target-based floor that
was collapsing the gap to zero for Green days (max(45, 50) = 50%).
Result: export only fires when battery is above 55%, stops at 45%, giving a
10% band of guaranteed discharge per export window.