A Model Context Protocol server for PyLabRobot. It exposes a liquid handler, a plate reader, a thermocycler, and a heater-shaker as MCP tools, so any MCP client (Claude Desktop, Claude Code, or your own agent) can run lab-automation steps by calling tools instead of writing PyLabRobot code.
It ships in simulation mode by default. Every tool runs end to end against PyLabRobot's chatterbox backends with no instruments attached, so you can try the whole thing on a laptop. Point it at real hardware by setting one environment variable (see below).
Verified against PyLabRobot 0.2.1.
Driving PyLabRobot from a Claude skill or direct tool-calls is tool-use inside one agent. An MCP server is a standalone process that speaks the Model Context Protocol over stdio, so any MCP client can discover and call these tools without knowing anything about PyLabRobot. This repo is the server.
git clone https://github.com/di-omics/plr-mcp.git
cd plr-mcp
pip install -e .This pulls in mcp and pylabrobot.
python examples/smoke_test.pyIt drives every tool through the chatterbox backends and prints ALL OK when
the run succeeds.
plr-mcp # stdio transport, chatterbox simulation
PLR_MCP_BACKEND=star plr-mcp # target a real liquid handler insteadEvery tool is registered under a plr_ prefix so it stays unambiguous when this
server is loaded next to others.
| Tool | What it does |
|---|---|
plr_connect_check |
Zero-motion hardware pre-flight: open the link to a real instrument, read its identity, close. Does not move the arm. See the hardware bring-up guide. |
plr_setup_deck |
Build the liquid handler for the chosen backend and, for the liquid handler family, place a tip rack and a 96-well plate. Call this first. home=true homes a real STAR (motion; deck must be clear). |
plr_deck_state |
List the resources on the deck and the run mode. |
plr_pick_up_tips |
Pick up tips from the tip rack for a well range (for example A1:H1). |
plr_drop_tips |
Return tips to the rack. |
plr_aspirate |
Aspirate a volume from each plate well in a range. |
plr_dispense |
Dispense a volume into each plate well in a range. |
plr_transfer |
One head pass: pick up, aspirate, dispense, drop. |
plr_read_plate |
Read absorbance, fluorescence, or luminescence. |
plr_thermocycler |
Set block or lid temperature, open or close the lid, deactivate, status. |
plr_heater_shaker |
Set temperature, shake, stop, deactivate, status. |
plr_generate_analysis_pipeline |
Generate a tool-agnostic, UMI-aware single-cell RNA-seq workflow with runtime-configured hooks for optional demultiplexing, UMI preprocessing, alignment, counting, and downstream analysis. Hook implementations are not bundled. |
plr_run_pcr_enrichment_round1 |
Run a validated PCR enrichment round 1 master-mix protocol by importing and executing the operator's existing starlab script (not a reimplementation). chatterbox dry-runs; star requires confirm=true (human-gated). See below. |
Well ranges use PyLabRobot syntax: a single well A1, a column A1:H1, or a
partial column A1:D1.
Beyond names, the tools carry machine-readable metadata so an agent can use them safely:
- Annotations. Each tool advertises MCP hints (
readOnlyHint,destructiveHint,idempotentHint,openWorldHint). Probes likeplr_connect_check,plr_deck_state, andplr_read_plateare read-only;plr_setup_deck(withhome), the liquid-handling tools,plr_thermocycler,plr_heater_shaker, andplr_run_pcr_enrichment_round1are marked destructive, so a client can warn before anything moves on real hardware. simulatedflag. Every result includessimulated.truemeans the numbers came from a chatterbox backend with no instrument attached; never read asimulated: truevalue as a real measurement.- Structured output. Tools declare an output schema and return
structuredContent, so clients parse results against a named shape instead of an opaque object (requiresmcp>=1.9). - Errors. Invalid arguments and unmet preconditions (unknown backend, bad
well range, moving before
setup_deck/home) are raised as tool errors. Expected operational states a correct call can still hit (hardware unreachable from this host, missing vendor extra, a human-gated real run awaitingconfirm=true) come back as a normal result withok: falseand anoteslist to act on.
This repo ships a project-scoped .mcp.json, so just open the repo
in Claude Code and approve the plr server when prompted (check /mcp or
claude mcp list). It starts on the chatterbox backend, and Claude Code loads
CLAUDE.md for the tool catalog and safety rules. Tools appear
prefixed plr_ (for example plr_aspirate).
Prefer to register it yourself instead:
claude mcp add --transport stdio plr -- plr-mcpEither way, plr-mcp must be on PATH (pip install -e .); otherwise use the
absolute path from which plr-mcp, or -- python -m plr_mcp.server.
Add this to claude_desktop_config.json:
{
"mcpServers": {
"plr": {
"command": "plr-mcp"
}
}
}If plr-mcp is not on the client's PATH, use the absolute path to the console
script (which plr-mcp) or run it as python -m plr_mcp.server.
Pick the liquid-handling backend with PLR_MCP_BACKEND, or override it per
session in a setup_deck call (backend="star", etc.).
| Backend | PyLabRobot backend | Deck | Runs with no hardware |
|---|---|---|---|
chatterbox |
LiquidHandlerChatterboxBackend |
STARLet | yes (default) |
star |
STARBackend (liquid handler) |
STARLet | no |
ot2 |
OpentronsOT2Backend (needs host) |
OTDeck | no |
evo |
EVOBackend (Tecan Freedom EVO) |
EVO150 | no |
Only chatterbox runs with no instrument. The other three construct the real
PyLabRobot backend (correct API for 0.2.1) and attempt to connect; if no
instrument is reachable, or a vendor extra such as pylabrobot[opentrons] is
not installed, setup_deck reports that in notes instead of crashing. The
liquid handler tip and plate auto-load only for chatterbox and star; ot2 and
evo use vendor-specific labware, so load your own.
Driving a real STAR moves a physical arm. setup_deck(home=true) homes the
channels and iSWAP. The star backend defaults to a zero-motion connect and
blocks every liquid-handling tool until you home on a clear deck. Follow the
hardware bring-up guide for the first run.
For ot2, pass the robot IP:
PLR_MCP_BACKEND=ot2 PLR_MCP_OT2_HOST=169.254.1.1 plr-mcpThe non-liquid-handling instruments (plate reader, thermocycler, heater-shaker)
run on chatterbox simulation and expose real hardware backends as clearly
marked extension points in plr_mcp/lab.py (the _ensure_* methods). Wire in
your own (for example an Inheco ODTC thermocycler or a BioTek reader) and
validate on your deck before trusting a run.
run_pcr_enrichment_round1 does not reimplement a protocol. It imports an existing,
hardware-validated starlab script and calls its own functions. Liquid parameters,
geometry, and tip logic remain operator-owned in that external run card; the MCP
wrapper does not bundle them and fails closed when the transfer contract is
incomplete. Point it at the scripts:
export PLR_MCP_STARLAB_DIR=/path/to/plr-tested/liquid-handler/starlab_liveOn a real run, follow the same ladder the scripts require: a clean
chatterbox dry-run, then mode='deck' on the instrument (assignment only),
then the transfer with a person watching. The star backend refuses to run
without confirm=true, because a real run homes the arm and moves liquid.
.mcp.json Claude Code project-scoped registration (starts on chatterbox)
CLAUDE.md guide Claude Code auto-loads (tools + safety rules)
plr_mcp/
lab.py stateful PyLabRobot wrapper (all the real calls live here)
server.py FastMCP server, one thin tool per Lab method
schemas.py TypedDict result shapes (the tools' output schemas)
protocols.py validated starlab protocol wrappers (run_pcr_enrichment_round1)
analysis.py single-cell RNA-seq pipeline generator
tests/
test_lab.py pytest suite, runs on chatterbox (no hardware)
examples/
smoke_test.py end-to-end run with no hardware
evals/
plr_mcp_eval.xml agent-usability questions answerable on chatterbox
pip install -e '.[dev]'
ruff check plr_mcp tests # lint
ruff format --check plr_mcp tests
mypy plr_mcp --check-untyped-defs
pytest -qCI runs all four on Python 3.10 through 3.13 for every push and pull request.
MIT