Step / Transient-Response Metrics

Overview & Motivation

When a control system or filter receives a step input, its output traces a transient trajectory before settling at the final value. Quantifying that trajectory with standardised scalar metrics — rise time, settling time, percent overshoot, peak time, and steady-state error — is the primary acceptance test for any closed-loop design. These metrics translate the raw sample sequence into the language of control specifications, allowing automated pass/fail decisions without manual inspection of time-domain plots.

Mathematical Theory

Definitions

Let $y[k]$, $k = 0, \ldots, N-1$ be the sampled step response and $y_{ss}$ the steady-state value. The sample period is $\Delta t$.

Rise Time $T_r$

The elapsed time for the response to travel from 10 % to 90 % of steady state:

$$T_r = (k_{90} - k_{10}),\Delta t$$

where $k_{10} = \min{k : y[k] \ge 0.1,y_{ss}}$ and $k_{90} = \min{k \ge k_{10} : y[k] \ge 0.9,y_{ss}}$.

Settling Time $T_s$

The first time after which the response remains permanently inside the band $[(1-\delta)y_{ss},,(1+\delta)y_{ss}]$ (typically $\delta = 0.02$):

$$T_s = (k^* + 1),\Delta t, \quad k^* = \max{k : |y[k] - y_{ss}| > \delta,|y_{ss}|}$$

Percent Overshoot $%OS$

$$%OS = 100,\frac{y_{\max} - y_{ss}}{y_{ss}}, \quad y_{\max} = \max_k y[k]$$

For an underdamped second-order system with damping ratio $\zeta$:

$$%OS = 100,\exp!\left(-\frac{\pi\zeta}{\sqrt{1-\zeta^2}}\right)$$

Peak Time $T_p$

$$T_p = k_p,\Delta t, \quad k_p = \arg\max_k y[k]$$

For a continuous underdamped second-order system with natural frequency $\omega_n$:

$$T_p = \frac{\pi}{\omega_n\sqrt{1-\zeta^2}}$$

Steady-State Error $e_{ss}$

$$e_{ss} = r - \bar{y}_{\text{tail}}$$

where $r$ is the reference (command) value and $\bar{y}_{\text{tail}}$ is the mean of the final quarter of the response buffer, providing a robust estimate of the achieved steady state.

Complexity Analysis

Case Time Space Notes
All $O(N)$ $O(1)$ Single forward pass; no auxiliary storage

Each metric requires at most one traversal of the $N$-element vector. The tail-mean for steady-state error adds a constant-fraction second scan of the same data — still $O(N)$ total.

Step-by-Step Walkthrough

Consider a 10-sample ramp to $y_{ss} = 1$ followed by a constant plateau (N = 20):

k:  0  1  2  3  4  5  6  7  8  9 10 11 …
y: 0  .1 .2 .3 .4 .5 .6 .7 .8 .9 1  1  …
  • Rise Time: $k_{10} = 1$ (first sample $\ge 0.1$), $k_{90} = 9$ (first sample $\ge 0.9$). $T_r = 8,\Delta t$.
  • Settling Time: With $\delta = 0.02$, last sample outside the band is $k = 9$. $T_s = 10,\Delta t$.
  • Percent Overshoot: $y_{\max} = 1.0 = y_{ss}$, so $%OS = 0$.
  • Peak Time: $k_p = 10$ (first occurrence of max). $T_p = 10,\Delta t$.
  • Steady-State Error: Tail mean $= 1.0$, reference $= 1.0$. $e_{ss} = 0$.

Pitfalls & Edge Cases

Zero steady state. Division by $y_{ss}$ in percent overshoot is guarded; the function returns zero when $y_{ss} = 0$ to avoid a NaN.

Non-monotone ramp. If the response crosses 90 % before 10 % (e.g., DC offset or wrong initial condition), $k_{10}$ may be found after the first 90 % crossing. The implementation returns the first pair that satisfies the threshold order.

Oscillatory settling. Settling time is defined as the last time the trajectory leaves the band, not the first time it enters it. Repeated crossings near the boundary extend the metric correctly.

Finite buffer. With a bounded vector of length $N$, if the response has not yet settled by the final sample, SettlingTime returns $N,\Delta t$ and RiseTime returns $(N-1),\Delta t$ as conservative bounds.

Tail-mean length. Using the last $\lfloor N/4 \rfloor + 1$ samples for the steady-state estimate assumes the transient has decayed to within numerical noise by that point. Poorly chosen $N$ relative to the system time constant degrades the estimate.

Variants & Generalizations

  • Delay Time $T_d$: the time to reach 50 % of steady state — obtainable with the same threshold-scan pattern.
  • Band-relative rise time: using a band other than 10–90 % (e.g., 20–80 %) is a trivial parameter change.
  • Multi-channel: applying the scalar functions element-wise to each row of a response matrix generalises to MIMO systems without algorithmic change.

Applications

  • Automated controller tuning acceptance: verify that a PID or LQR design meets specification ($T_r < T_{r,\text{spec}}$, $%OS < %OS_{\text{spec}}$, etc.).
  • Filter characterisation: measure the transient of a step fed through an IIR or FIR filter.
  • Hardware-in-the-loop test harnesses: compute metrics directly from sampled actuator responses.

Connections to Other Algorithms

  • Statistics (this library): the tail-mean for steady-state error replicates the Mean function on a sub-range.
  • LinearTimeInvariant: the primary source of step responses whose metrics are evaluated here.
  • Filters/active (Kalman, EKF): step-excitation tests use these metrics to validate estimator transient behaviour.
  • Controllers: PID and LQR tuning loops iterate until all five metrics satisfy design targets.

References & Further Reading

  • K. J. Åström and R. M. Murray, Feedback Systems: An Introduction for Scientists and Engineers, Princeton University Press, 2008. Chapter 10.
  • G. F. Franklin, J. D. Powell, and A. Emami-Naeini, Feedback Control of Dynamic Systems, 8th ed., Pearson, 2019. Chapter 3.