wallbox-modbus

My Wallbox Pulsar Plus will only do Power Boost (dynamic load management) if it sees an INEPRO N1-CT energy meter on its RS485 port. This program pretends to be that meter, fed with live grid power from Home Assistant.

I didn't want to buy the accessory, and the meter turned out to be a stock Modbus device.

Status

Everything here comes from one charger, mine.

  • Works. Pulsar Plus, single phase, Home Assistant. I've watched it throttle the charge when the house load goes up.
  • Untested. Eco-Smart (solar). See Solar.
  • Refuses to run. Three-phase supplies. See Three-phase.
  • Needs. Linux, Python 3.10+, a USB-RS485 adapter, and access to the charger's terminal block.

Other Wallbox models (Copper SB, Commander 2, Quasar) use the same EMS docs and will probably work, but I haven't tried that. If you do, please tell me what happened.

How it works

The Power Boost accessory is an off-the-shelf INEPRO N1-CT, and the charger polls it as a plain Modbus RTU master:

Layer
Wiring RS485: D+, D−, GND
Serial 19200 8N1
Slave id 1 (it also scans 2 and 12)
Function 03 to read, 06 to write
Encoding big-endian float32 over two registers

The N1-CT manual says 9600 8E1, but that's wrong for this bus. I think Wallbox reconfigures the meter it ships. Set baud: auto and parity: auto if you want the emulator to find it for you.

So: read the house load, put it on the registers the charger asks for, and the charger does its own balancing. That's the right place for it, since the charger is the only thing that knows how much it's drawing.

The handshake

I couldn't find this documented anywhere, so here's what a Pulsar Plus does.

It only looks for a meter for about two minutes after it boots, then gives up until the next restart. This is why the app keeps saying no meter is connected while your wiring is perfectly fine. Start this program first, then reboot the charger from the app.

During those two minutes it cycles three probes, roughly every 0.6 s, against unit ids 1, 2 and 12:

Probe Looking for
1 register at 0x000B Carlo Gavazzi id code (EM340 answers 340)
1 register at 0x4002 INEPRO meter code
8 registers at 0x0000 and 0x0008 Carlo Gavazzi measurement block

0x4002 is the gate. Answer 0x0102 and it starts polling measurements 60 ms later. 0x0103 is rejected, even though that's the CT variant code and an N1-CT is a CT meter. Everything else can stay zero.

After that it settles into about 7.5 requests/second: voltage at 0x5002, current at 0x500C, power at 0x5014, energy at 0x6000 and 0x6018. It reads all three phases even from a single-phase meter. Zeros for L2 and L3 are fine.

Safety

  • Kill the breaker before you open the charger. The RS485 terminals are low voltage but the rest of the box isn't.
  • Opening it may void your warranty. Your call.
  • This thing guards a fuse. If it lies about the house load, the charger will happily pull its maximum on top of everything else. Read Failsafe.
  • Set the charger's rotary switch low (16 A) until you've seen it throttle.
  • It's not a certified load-management device and the MIT licence means what it says. The rotary switch is the only limit that survives this crashing.

Hardware and wiring

A USB-RS485 adapter with A, B and GND broken out. Not a USB-TTL programmer, they look alike and TTL levels on A/B can damage things. Automatic direction control (CH340, CH343, CP2102, FTDI) saves you fiddling with RTS. CH340 and FTDI show up as /dev/ttyUSB0; CH343 and CH9102 are CDC-ACM and show up as /dev/ttyACM0. TX/RX LEDs are worth it, they tell you the charger is transmitting before any software works.

Behind the front cover there's a four-pin block:

Charger N1-CT Your adapter
D+ 20 (A) A / D+
D- 21 (B) B / D−
GND 24 GND
12V 23 leave it, power your box separately

Connect GND. RS485 is differential but not ground-referenced. Skipping it works on the bench and fails in a meter cupboard.

Running it over spare pairs in Cat-5? Put D+ and D− on the two wires of one twisted pair. That twist is the whole noise-rejection mechanism. Use a second pair, both wires together, for ground.

Also set the RS485 switch to T (you're the only slave, so terminate), and the rotary switch to your maximum charging current (1=6A 2=10A 3=13A 4=16A 5=20A 6=25A 7=32A).

Then install the udev rules. They drop the FTDI latency timer from 16 ms to 1 ms, which otherwise lands right on the Modbus turnaround, and give you a stable device name so a second adapter can't steal /dev/ttyUSB0:

sudo cp udev/99-wallbox-rs485.rules /etc/udev/rules.d/
sudo udevadm control --reload && sudo udevadm trigger

Install

git clone https://github.com/erwindamsma/wallbox-modbus /opt/wallbox-modbus
cd /opt/wallbox-modbus
python3 -m venv .venv
./.venv/bin/pip install .
cp config.example.yaml config.yaml

Three settings have no sensible default:

  • limits.installation_current_a — your main fuse rating. Required. Set the same number under Load Management in the app.
  • source.token — a Home Assistant long-lived token (profile → Security).
  • source.power_entity — the sensor with net grid power, positive when importing. --list-entities will find it.

failsafe.current_a is derived from your fuse rating unless you set it.

As a service:

sudo useradd -r -G dialout wallbox
sudo install -D -m 640 -o wallbox config.yaml /etc/evse-meter/config.yaml
sudo cp systemd/evse-meter.service /etc/systemd/system/
sudo systemctl enable --now evse-meter

config.yaml has a token in it. It's gitignored and the unit installs it 0640.

Bring-up

Do these in order, each one fails differently.

1. Test the logic. ./.venv/bin/python tools/selftest.py — pty pair, no hardware.

2. Test the data. --list-entities to find your sensor, then --check-source to watch it live without touching the serial port. Switch on a kettle. The number must go up. If it goes down your sensor is inverted, and Power Boost would speed up exactly when it should back off.

3. Test the stack. Three terminals, no hardware:

./.venv/bin/python tools/vlink.py
./.venv/bin/python -m evse_meter -c config.yaml --port /tmp/wallbox-a --parity none
./.venv/bin/python tools/test_master.py /tmp/wallbox-b --parity N

Use parity none here. A pty has no UART and can't emulate parity.

4. Test the wiring with a second adapter over real RS485, A–A, B–B, GND–GND.

5. Listen first. Wire it to the charger, run with --passive --log-level DEBUG, and reboot the charger. It decodes but never transmits, so you can see what the charger asks for. Leave baud and parity on auto and it'll log what it locked onto.

Seeing nothing at all? try swapping D+ and D−.

6. Answer it. Drop --passive, reboot the charger. Success is a burst of 0x4000 reads followed by steady polling of 0x500A and 0x5012.

7. Prove it throttles. The charger should allow you to enable Power Boost / Dynamic load balancing in the app. Enable it and start a charge, confirm it's charging at whatever max you chose, then switch on an oven. The charge current should drop within seconds. That's the whole point, and until you've seen it you don't have load management.

When the charger won't accept the meter

  1. Is it still hunting? Two minutes after boot, that's it. Restart it.
  2. Read the log. Unmapped reads get logged once each as charger read unmapped register 0x40XX. A register it insists on that isn't in the N1-CT manual is the best clue you can get, and I'd like to see it.
  3. Check for writes. charger wrote 0x4004 means it's reconfiguring baud or parity. The emulator applies it and reopens the port.
  4. Try other identity values. meter_code first, [0x0102, 0x0103] tries both in one detection window. Then software_version, then serial_number.
  5. Try unknown_register_policy: exception. Answering zeros to everything is permissive, and a charger ruling models out may expect a refusal.
  6. Check the app. Installer settings must have the meter set to N1-CT. Picking EM340 or the P1 module gives you a completely different register map.

Three-phase

Not supported. meter.phases must be 1 and the program exits if it isn't.

The N1-CT is single phase and I only have one number to report, so L2 and L3 would read 0 A. The charger takes that as "those phases are idle" and draws freely on them. It would look like it was working while protecting nothing, which is worse than not running.

Doing it properly needs per-phase data and emulation of a meter Wallbox actually pairs with three-phase installs (INEPRO N3, or the Carlo Gavazzi EM340 the charger already probes for). I can't test either. PRs welcome.

Limits

Two separate limits, doing separate jobs:

  • The rotary switch caps the charger in its own firmware. It holds if this crashes, if the cable falls out, if Home Assistant dies, and if everything I think I know about Power Boost is wrong. Nothing here can override it.
  • limits.installation_current_a is your fuse, and what the charger balances against. Match it to the app.

With a 35 A fuse and the switch at 16 A: idle house, charger takes 16 A. House at 25 A, Power Boost allows 10 A. This program dies, charger is still capped at 16 A.

The emulator has no limit of its own on purpose. A meter can't address the charger and can't separate the charger's draw from the rest of the house, so anything it did here would mean lying about the measurement, and it would fall apart while exporting.

Solar

I have not tested this. Power Boost I proved with a kettle. Eco-Smart I've never even switched on, and no charge session has run on solar surplus.

What I do know is that the meter reports export correctly: 0x5012 goes negative, current stays an unsigned magnitude, reverse energy accumulates. That matches what a real CT does, direction lives in the sign of the power.

What I don't know is whether the charger reads that sign or just the magnitude. If it throttles while you're exporting, it's ignoring the sign, and current_sign: signed should fix it. That setting exists precisely because I couldn't test this. If you find out which one is right, please tell me.

Failsafe

If no fresh reading arrives within failsafe.max_data_age_s (15 s), the meter reports failsafe.current_a instead of the last value it had. The charger sees the installation over its limit and backs off.

That number has to be above installation_current_a and the config won't start otherwise. Reporting exactly the limit is a fixed point of the charger's control loop (allowance = limit − (limit − own_current)), so it would just sit there instead of backing off.

This matters more than it looks. Home Assistant restarting, wifi dropping, the P1 reader hanging: all of them leave a perfectly plausible last reading. A stale "house is drawing 300 W" is exactly what lets the charger sit at maximum while the oven is on. Better to keep the link up and lie pessimistically, because a charger that loses its meter may fault instead of throttling.

Energy counters are integrated from power and persisted, so they stay monotonic across restarts like a real meter's would.

Register map

From the N1 CT manual V1.17 section 9. Two registers each, big-endian float32 unless noted. --dump-map prints it with live values.

Register Contents Type
0x4000 Serial number int32
0x4002 Meter code int16
0x4003 Modbus id int16
0x4004 Baud rate int16
0x4005 Protocol version
0x4007 Software version
0x4009 Hardware version
0x400B Meter amps int32
0x400F Combination code int16
0x4011 Parity (1=even, 2=none, 3=odd) int16
0x401B Software CRC int32
0x5000 0x5002 Voltage, L1 voltage V
0x5008 Frequency Hz
0x500A 0x500C Current, L1 current A
0x5012 0x5014 Active power, L1 kW
0x501A 0x5022 Reactive, apparent power kvar, kVA
0x502A Power factor
0x6000 0x6006 Total energy, L1 kWh
0x600C 0x6018 Forward, reverse energy kWh

Writable with 06: 0x4003, 0x4004, 0x4011, 0x400F. The emulator accepts those and reopens the port with the new settings.

Power is in kW, not W. Send watts and the charger thinks your house is pulling 3450 kW.

Layout

File
rtu.py Modbus RTU slave: framing, CRC, resync, baud/parity probing
n1ct.py Register map, and logging what the charger asks for
model.py Meter state, energy integration, failsafe
sources/base.py What a data source is; source.type picks one
sources/homeassistant.py WebSocket with REST fallback
tools/selftest.py End-to-end over a pty pair
tools/test_master.py Polls the emulator like the charger does

Frames are delimited by expected length and CRC, not the usual 3.5-character idle gap, because USB serial adapters buffer with milliseconds of jitter.

Home Assistant isn't special, it's just the only source written so far. source.type picks a class out of a registry and that class brings its own config options. MQTT or a P1 reader would be one module, see CONTRIBUTING.md.

Alternatives

Any of these may suit you better, and two of them are supported products:

  • Wallbox's own Power Boost accessory. A meter, an install guide, and someone to call.
  • Wallbox's P1 module (P1MB) reads the Dutch smart meter's P1 port. Same idea, supported, in the official EMS guide.
  • A real N1-CT, wired as the accessory would be. No software to maintain.
  • Drive the charger instead. The myWallbox API can set the charging current from Home Assistant. Cloud-dependent and slow (tens of seconds), so it's a convenience feature rather than fuse protection.

Sources

Licence

MIT. Not affiliated with Wallbox Chargers S.L. or inepro Metering B.V.