Make inverter serial optional for hybrid Modbus setup
Issue #20's follow-up added serial auto-detection (registers
33004-33019) but the schema still required typing something into a
blank field even though hybrid models immediately overwrite it once
validated. CONF_INVERTER_SERIAL is now optional (default ""); if it's
still blank after validation (grid/string model, or a failed
detection read), the form is shown again with a clear error instead
of silently creating an entry with an empty serial.
The dual-protocol Modbus step needs no equivalent change: its final
entry serial always comes from the cloud-resolved value, not the
Modbus step's data.
Copy file name to clipboardExpand all lines: README.md
+4-3Lines changed: 4 additions & 3 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -117,10 +117,11 @@ Home Assistant only allows one `iot_class` value in the manifest. SolisConnect i
117
117
- The SolisCloud API is rate-limited by the integration. Avoid running another cloud integration against the same key if you are seeing slow or failed cloud updates.
118
118
- If older debug logs captured SolisCloud credentials before redaction was added, rotate the SolisCloud key secret and clear old logs.
119
119
120
-
**Inverter Serial**: (Required)
120
+
**Inverter Serial**: (Optional on hybrid Modbus models and SolisCloud; required otherwise)
121
121
122
-
- Enter your inverter's serial number. This is now **mandatory** for generating unique entity IDs and ensuring configuration stability.
123
-
- On Modbus hybrid inverters, once connectivity is confirmed the integration reads the serial directly from the device and silently corrects a mistyped value (grid/string models don't expose this register, so the typed value is used as-is). On SolisCloud, the serial is optional and auto-resolved when your plant has exactly one inverter.
122
+
- Used to generate unique entity IDs and ensure configuration stability — every entry needs one, but you don't always have to type it.
123
+
- On Modbus **hybrid** inverters, you can leave this blank: once connectivity is confirmed, the integration reads the serial directly from the device and uses it (silently correcting a mistyped value too, if you did type one). **Grid/string** models don't expose this register, so you still need to type it there — if you leave it blank on a grid/string model, the form will ask again.
124
+
- On SolisCloud, the serial is optional and auto-resolved when your plant has exactly one inverter; you only need to type it to disambiguate a plant with multiple inverters.