Distinguish operational controls from configuration entities
Follow-up to the EntityCategory work in #28: introduces a "control"
flag on sensor/switch/select/time entity definitions so genuine
operational controls (storage-mode bits, TOU V2 enable switches, TOU
V2 SOC/current/voltage/time entities, Work Mode select, the active-
protocol select) stay in the default category instead of being
lumped into EntityCategory.CONFIG alongside one-time settings.
Also renames storage-mode switch bits to a shorter "Mode - X" scheme,
disables two rarely-used bits (Battery Forcecharge Peakshaving,
Battery Current Correction) by default, and unifies TOU V2 entity
names to "Timed Charge {field} N" (N=1-6 charge slots, 7-12 discharge
slots), mirroring how V1 TOU already uses "Time-Charging" as an
umbrella term for both directions.
A new _apply_control_metadata() helper in hybrid_sensors.py tags and
renames entities by register instead of hand-annotating each dict.