Map HMI/DSP firmware version to SolisCloud; fix V1 TOU doc slot count - #6

Closed
fboundy wants to merge 2 commits into
mainfrom
cloud-hmi-version-mapping
Closed

fboundy wants to merge 2 commits into
mainfrom
cloud-hmi-version-mapping

Conversation

@fboundy

@fboundy fboundy commented Jul 3, 2026

Copy link
Copy Markdown
Owner

Summary

  • Adds SolisCloud mapping for DSP Version (register 33001) and HMI Version (register 33002) from inverterDetail's dspmVersionAll/hmiVersionAll fields (4-hex-char strings == the raw register value), confirmed against a live inverterDetail dump. These sensors were previously unavailable in cloud-only/dual mode.
  • Fixes a docs error: docs/source/tou.md said Time-Charging (V1) has 4 slots; it actually has 5 (43143-43190, bases at 43143/43153/43163/43173/43183).
  • Documents SolisCloud control CID 103 as the (not yet implemented) path to V1 TOU cloud support — it only covers 3 of the 5 Modbus slots and uses per-slot charge/discharge current instead of Modbus's single global current pair. Full field layout, the worked example from the SolisCloud command-list workbook, and a step-by-step implementation plan are recorded in WORKING_NOTES.md (gitignored, not part of this diff) for a follow-up PR.

Test plan

  • tests/test_cloud_mapping.py: 3 new tests (hex-string decode for HMI/DSP version, rejection of non-hex values).
  • Full suite: 267 passed (was 264). Ruff check + format clean.

🤖 Generated with Claude Code

…docs

Adds SolisCloud support for the DSP/HMI firmware version sensors:
inverterDetail's hmiVersionAll/dspmVersionAll fields are 4-hex-char
strings equal to the raw Modbus register value (registers 33002/33001),
confirmed against a live inverterDetail dump. Cloud-only/dual entries
previously left these unavailable.

Also corrects docs/source/tou.md: Time-Charging (V1) has 5 slots on
Modbus (43143-43190), not 4, and documents SolisCloud control CID 103
as the (not yet implemented) path to V1 TOU cloud support, including
the 3-slot/per-slot-current mismatch vs Modbus's 5-slot/global-current
model. Full field layout and implementation plan recorded in
WORKING_NOTES.md.

Tests: 267 passed (3 new). Ruff clean.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
@github-actions

github-actions Bot commented Jul 3, 2026

Copy link
Copy Markdown
Contributor

Failed to generate code suggestions for PR

The official RS485_MODBUS Hybrid Inverter protocol document only
documents Time-Charging slot 1 (43141-43150); registers 43152-43249
are one contiguous Reserved block. SolisConnect's own hybrid_sensors.py
extends this to slots 2-3 (43153, 43163) - undocumented in that PDF
revision but independently confirmed by SolisCloud control CID 103,
which covers exactly 3 slots - and then further to "slots 4-5"
(43173, 43183), which fall inside the vendor's Reserved range with no
confirmation from any source.

Corrects the previous doc pass (which had already wrongly corrected
"4 slots" to "5"); the real count is 3. Adds a "Known issue" section
flagging slots 4-5 as an unresolved, likely-fictional feature pending
the user's decision on remediation. Also updates the CID 103
implementation plan notes in WORKING_NOTES.md (26 registers = 2 global
+ 3 slots x 8, not affected by this correction) to reflect that, once
implemented, cloud coverage of V1 TOU would actually be complete
rather than partial.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
@fboundy

fboundy commented Jul 3, 2026

Copy link
Copy Markdown
Owner Author

Consolidated onto the patch branch directly per request — this content is now on patch (commits 0b6be11, d042255) and will go out via the patch -> main PR instead of its own branch.

@fboundy fboundy closed this Jul 3, 2026