Validation evidence

The validation lab exports one local JSON evidence bundle per physical measurement session. The artifact is designed to make recurrence, blinded reconstruction review, and device playability review auditable without exporting microphone audio.

Schema version 5

A validation-evidence-5 bundle contains:

  • a stable session ID and creation time;
  • the exact 40-hex software commit revision that produced the evidence;
  • a required stable physical specimenId, plus human-readable object label and material class;
  • the declared fixed-setup protocol: microphone distance, striker, strike location, and support condition;
  • actual capture settings reported by the browser;
  • exactly the retained qualified attempts, where qualification means the acquisition-quality gate passed;
  • per-attempt capture-quality metrics;
  • one terminal analysis outcome per qualified attempt: a complete versioned acoustic fingerprint or an explicit analytical failure reason;
  • one-to-one recurrence measurements using successful attempt 1 as the fixed reference;
  • browser audio-thread and output-path timing diagnostics when available;
  • blinded Gate B reviews, including the hidden A/B presentation order and exact session/attempt target;
  • Gate C reviews tied to the exact session/attempt target and to the device ID/class used for playback.

Raw microphone PCM is intentionally excluded. Every bundle contains rawMicrophoneSamplesIncluded: false, and the parser rejects a bundle that violates that invariant.

Software and algorithm provenance

Every schema-v5 bundle must contain softwareRevision, a lowercase 40-hex Git commit SHA. The validation lab disables release evidence collection when its build is unstamped. CI and the Pages deployment inject the exact build SHA through VITE_SOFTWARE_REVISION.

Each successful fingerprint also carries an explicit algorithm identifier. er-dsp-1 denotes the historical estimator. er-dsp-2 denotes the estimator with the -60 dB relative-amplitude measurement floor. The parser keeps both identifiers readable so historical evidence remains interpretable, but one physical session and one release evaluation must each use a single fingerprint algorithm version.

Gate A release evaluation requires one software revision across all imported sessions, including sessions that fail physically. Mixing evidence produced by different implementations is an evidence-integrity failure. Re-exporting one session under a different revision is also rejected by the immutable measurement-core merge.

The SHA is the authoritative implementation provenance identifier; the fingerprint algorithm identifier records the estimator semantics carried by each successful analytical outcome.

Physical specimen identity

specimenId is the release identity axis. It identifies one physical test specimen across measurement sessions. The object label is descriptive metadata only.

The same physical specimen must reuse the same normalized specimenId even if its display label changes. Multiple sessions with the same specimen ID can support repeatability and listening evaluation, but they still represent one specimen for release distinctness. Reusing a specimen ID with conflicting material classes is an evidence-integrity failure.

The parser requires a non-empty specimen ID. The release evaluator groups Gate A distinctness and Gate B/C specimen provenance through this identity, so relabeling one object cannot manufacture extra release specimens.

Qualified-attempt invariant

Acquisition-quality failures are not retained in the five-attempt Gate A2 experiment. Once acquisition quality passes, the physical attempt is final and receives the next sequential attempt ID. Its subsequent analysis outcome cannot be removed or replaced. NO_STABLE_RESONANCES, SIGNAL_TOO_SHORT, and ANALYSIS_INTERNAL_ERROR are retained analytical outcomes.

Schema v5 retains v4's qualified-attempt semantics and adds mandatory software provenance. The earlier record-only schema v3 remains superseded because it could not make analytical failures visible without a selection loophole. Schema v4 is rejected for release collection because it did not bind evidence to the implementation revision that produced it.

A true session-level internal error terminates that physical session in the validation UI. Retained evidence can be exported, but another qualified attempt is not permitted on the same potentially compromised worker/audio resources. Further capture uses a new session ID; if it is the same physical specimen, the same specimenId is retained.

Consistency checks

The retained attempts and successful fingerprints are the source of truth for Gate A2. On import, the parser validates specimen identity, the complete fingerprint shape and diagnostics, requires sequential qualified-attempt IDs, requires one fingerprint algorithm version within a session, recomputes recurrence from the retained successful fingerprints, and rejects cached recurrence rows or aggregate drift that disagree with recomputation. The release evaluator also recomputes recurrence independently instead of trusting cached medians or match counts and rejects mixed fingerprint algorithm versions across release evidence.

The first qualified attempt is the fixed recurrence reference. If it fails analysis, no later attempt is substituted. Recurrence cache entries therefore exist only for later successful attempts when attempt 1 itself succeeded.

Review targets must belong to successful attempts in their owning evidence bundle. Duplicate or non-sequential attempt IDs, malformed quality/timing values, invalid modal ranges, duplicate review IDs, duplicate logical reviewer judgments, dangling review targets, and cross-session review targets are rejected. Device IDs must also map consistently to one device class.

These checks establish internal consistency and make accidental or stale evidence fail closed. They do not constitute cryptographic attestation of the physical experiment; the protocol still relies on honest specimen identification, capture, and review practice.

Repeated exports from one session

A session ID identifies one immutable physical measurement core: software revision, specimen identity, object label and material, fixed setup, capture settings, qualified attempts, analytical outcomes, fingerprints, and derived recurrence evidence. Re-exporting the same session after adding listening/device reviews is supported.

The Release Console merges repeated exports only when that immutable measurement core is identical. Additional uniquely identified reviews are combined. Reusing the same session ID with a changed software revision, specimen identity, or qualified-attempt evidence, changing a retained failure into a success, reusing one review ID with conflicting contents, or submitting a conflicting second logical judgment is rejected instead of silently replacing earlier evidence.

Local release console

Open the web application with ?release=1 to use the Release Console. It imports schema-v5 JSON bundles locally, evaluates the frozen gate-a-2, gate-b-1, and gate-c-1 contracts, exposes every failed criterion, and exports one canonical release-verdict JSON artifact.

The console performs no upload. Imported evidence remains in browser memory for the current page session.

A release verdict does not reinterpret missing evidence as a pass. Gate A2 release distinctness is counted by normalized physical specimen ID. Gate B uses only blinded reviews tied to the final eligible attempt of Gate A2-passing sessions and groups those sessions by specimen. Gate C uses only reviews tied to the exact measurement target selected by Gate B. The overall release state is ready only when all three gates pass.

Release metrics preserve those ontology levels explicitly: Gate A reports passingSessionCount and distinctPassingSpecimenCount; Gate B and Gate C report passingSpecimenCount. A repeated passing session for one specimen therefore cannot be mistaken for another passing physical specimen in the machine-readable verdict.

Versioning rule

Thresholds and evidence contracts are frozen before the corresponding release data is collected. The v5/A2 provenance migration occurred before the release physical dataset was accepted. It preserves the v4 no-selection and specimen-identity invariants and additionally binds every bundle to one implementation commit. Once Gate A2 release data collection starts, threshold, attempt, or specimen-identity protocol changes require another explicit contract version.

Algorithm or renderer changes made after a failed gate require a versioned validation cycle. Historical evidence remains interpretable under the contract, algorithm identifier, and software revision that produced it.