Merge: Tank-Heizstab an WP1 bleibt bewusst auf extern
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2 parents 52afd3e + 469f577 commit 22c3046

2 files changed

Lines changed: 14 additions & 1 deletion

File tree

‎MQTT-Topics.md‎

Lines changed: 8 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -480,6 +480,14 @@ was visible before:
480480
unit 2 runs hot water - it uncouples itself from the hydraulics for a DHW run
481481
while unit 1 keeps heating. It becomes live the moment a tank is configured
482482
there, which is worth knowing before that day and not after it.
483+
484+
**It stays as it is, deliberately** (owner, 2026-08-31). Correcting it is not
485+
possible without first enabling the tank connection on unit 1 - and that would
486+
mean configuring hardware that is not there, which is precisely the fault that
487+
took unit 2 down that morning. Tidying the value would risk the very failure
488+
the value documents. The topic is what makes leaving it safe: it reports the
489+
setting without anyone having to open a menu, so if a tank is ever fitted
490+
there, the state is known before it is needed rather than after.
483491
* **Heater capacity read `9 kW` on unit 1 against `3 kW` on unit 2** - and this
484492
one turned out to be the sharpest argument for reading these bytes at all.
485493
This model only ships with a 3 kW backup heater, so unit 1 was configured for

‎src/version.h‎

Lines changed: 6 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -55,7 +55,12 @@
5555
// der gemeinsame Ausgangszustand beider Anlagen. An WP1 ist er
5656
// derzeit folgenlos: dort haengt kein Speicher (TOP10 = -128, TOP58
5757
// Blocked, TOP91 = 0 Stunden). Er wird scharf, sobald dort ein Tank
58-
// konfiguriert wird.
58+
// konfiguriert wird - und BLEIBT BEWUSST STEHEN (Owner,
59+
// 2026-08-31): Den Menuepunkt gibt es erst nach Freigabe der
60+
// Tank-Verbindung, und die freizugeben hiesse, Hardware zu
61+
// konfigurieren, die es nicht gibt. Genau daran ist WP2 an diesem
62+
// Morgen ausgefallen. Das Aufraeumen des Wertes wuerde also den
63+
// Fehler riskieren, den der Wert dokumentiert.
5964
// - Die Heizstab-Leistung las an WP1 9 kW, an WP2 3 kW - und dieser
6065
// Befund ist das schaerfste Argument fuer die ganze Aenderung.
6166
// Diesen Geraetetyp gibt es nur mit 3 kW; WP1 war also auf Hardware

0 commit comments