Diagnostic commands are an advanced support tool for running a short, developer-provided scenario through the collector connection that already belongs to an EyeBond Local entry.

Most users never need this tool. Start with a Support Archive and use diagnostic commands only when a developer asks for a specific scenario.

Safety boundary

  • read and sleep do not change inverter settings.
  • write, write_bit, and free-form ascii commands can change the device.
  • Any scenario containing a potentially changing command is refused unless Confirm commands that may change settings is enabled.
  • The scenario can temporarily override the driver or wire addresses for that run, but it does not rewrite the config entry.
  • Only one diagnostic scenario runs for an entry at a time, using its current owned collector session.

Do not invent a write scenario or copy one intended for a different model. Only run the exact commands supplied for your device by a developer you trust.

How to run a scenario

  1. Open Settings → Devices & Services → EyeBond Local → Configure.
  2. Open Diagnostics and service tools.
  3. Choose Run diagnostic commands.
  4. Paste the complete multiline scenario.
  5. Leave Stop after the first error enabled unless the developer says otherwise.
  6. Enable the write confirmation only when the supplied scenario contains a deliberate write or ASCII command.
  7. Submit the form and wait for the result.

The same runner is available as the eybond_local.run_diagnostic_commands action under Developer Tools → Actions.

Scenario format

Optional directives must appear before the first command:

Directive Meaning
driver <key> Temporarily use a specific installed driver.
devcode <number> Override the run-scoped inverter device code.
collector_addr <number> Override the collector-side address.
device_addr <number> Override the inverter address.
stop_on_error <true|false> Stop or continue after a failed command.
operation_timeout <seconds> Set the per-operation timeout for this run.

Supported commands are:

Command Meaning
read <register> [count] Read one or more Modbus registers.
write <register> <value> [value ...] Write one or more register values.
write_bit <register> <bit> <0|1> Change one bit in a register.
ascii <command> Send one driver-supported ASCII command.
sleep <milliseconds> Pause between commands.

A harmless example that reads one register is:

read 171 1

Driver and address overrides are intentionally not shown in a generic example; they must match the exact collector and inverter protocol.

Results and downloads

The form shows the output from the latest run and the local result path.

If Create shareable download link is enabled, EyeBond Local creates a redacted copy and a short-lived signed download URL. The URL is scoped to the current entry and result. The unredacted local result is not exposed through that download route or copied into /config/www.

Download the shareable result promptly and attach it to the relevant issue. A normal Support Archive may still be requested because it contains the wider runtime and device context.

If a scenario fails

Check that:

  • the EyeBond Local entry is loaded;
  • the collector is connected;
  • inverter entities are not in the middle of a reconnect or protocol scan;
  • the scenario was copied completely, with directives before commands;
  • write confirmation was enabled only when required.

If the same developer-provided scenario still fails, create a fresh Support Archive and report both the visible error and the command result.