You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Commit 024411d
Browse filesBrowse the repository at this point in the historyBrowse files
Copy file name to clipboardExpand all lines: catalog/inverter_models/models/anenji_anj_11kw_48v_wifi_p.json
+16-1Lines changed: 16 additions & 1 deletion
Original file line number
Diff line number
Diff line change
@@ -13,6 +13,19 @@
13
13
"anenji_anj_11kw"
14
14
],
15
15
"known_firmware": []
16
+
},
17
+
{
18
+
"variant_key": "layout4_model33793",
19
+
"label": "Anenji 11kW model-code 0x8401 variant",
20
+
"device_descriptor_keys": [
21
+
"anenji_anj_11kw_8401"
22
+
],
23
+
"validation": {
24
+
"hardware": "captured",
25
+
"telemetry": "confirmed",
26
+
"controls": "partial"
27
+
},
28
+
"known_firmware": []
16
29
}
17
30
],
18
31
"validation": {
@@ -27,6 +40,7 @@
27
40
"notes": [
28
41
"Device-specific runtime profile is user-confirmed.",
29
42
"Communication Protocol No. 3-10 documentation defines the protocol-4 telemetry projection used by this model.",
43
+
"The captured 0x8401 hardware fingerprint uses the documented Protocol 4 telemetry surface; its write controls remain untested and require explicit Full Control.",
30
44
"Register 602 secondary-output priority is documented and hardware-read-correlated; local write behavior remains conditional pending a device retest."
"summary": "A beta.4 support archive captured the exact Modbus fingerprint layout 4 and model code 0x8401 for an Anenji ANJ-11KW-48V-WIFI-P. The same collector and inverter identity had previously been classified by the cloud as devcode 6544 and had operated through the Anenji Protocol 4 map on v0.2.0. The new fingerprint therefore receives exact commercial identity and Protocol 4 telemetry, while its local write controls remain explicitly untested.",
Copy file name to clipboardExpand all lines: custom_components/eybond_local/protocol_catalogs/inverter_catalog.json
+43-1Lines changed: 43 additions & 1 deletion
Original file line number
Diff line number
Diff line change
@@ -1,6 +1,6 @@
1
1
{
2
2
"schema_version": 2,
3
-
"catalog_version": "2026.08.7",
3
+
"catalog_version": "2026.08.8",
4
4
"description": "Universal offline inverter catalog with reusable protocol actions, runtime surfaces, and deterministic identity evidence.",
5
5
"protocols": [
6
6
{
@@ -1925,6 +1925,48 @@
1925
1925
"confidence": "capture-derived"
1926
1926
}
1927
1927
},
1928
+
{
1929
+
"entry_key": "anenji_anj_11kw_8401",
1930
+
"fingerprint": {
1931
+
"layout_code": 4,
1932
+
"model_code": 33793
1933
+
},
1934
+
"structural": [
1935
+
"serial_ascii_plausible"
1936
+
],
1937
+
"model_name": "Anenji ANJ-11KW-48V-WIFI-P",
1938
+
"surface_key": "smg_protocol_4_family_fallback",
1939
+
"runtime_probe": {
1940
+
"validation": [
1941
+
{
1942
+
"key": "output_rating_voltage",
1943
+
"min": 1
1944
+
},
1945
+
{
1946
+
"key": "output_rating_frequency",
1947
+
"min": 1
1948
+
},
1949
+
{
1950
+
"key": "protocol_number",
1951
+
"one_of": [
1952
+
4
1953
+
]
1954
+
}
1955
+
]
1956
+
},
1957
+
"cloud_hints": {
1958
+
"devcodes": [
1959
+
6544
1960
+
]
1961
+
},
1962
+
"provenance": {
1963
+
"sources": [
1964
+
"project-issue:13 support archive (2026-08-30): layout_code=4, model_code=0x8401, stable serial and responsive Protocol 4 telemetry",
1965
+
"project-issue:13 historical evidence: the same collector/inverter identity was cloud-classified as devcode 6544 and operated through the Anenji Protocol 4 map on v0.2.0"
@@ -107,6 +108,7 @@ Runtime descriptors with no specific commercial model record. These are generic
107
108
- Coverage notes:
108
109
- Device-specific runtime profile is user-confirmed.
109
110
- Communication Protocol No. 3-10 documentation defines the protocol-4 telemetry projection used by this model.
111
+
- The captured 0x8401 hardware fingerprint uses the documented Protocol 4 telemetry surface; its write controls remain untested and require explicit Full Control.
110
112
- Register 602 secondary-output priority is documented and hardware-read-correlated; local write behavior remains conditional pending a device retest.
111
113
- Summary: Anenji 11kW unit with a model-specific control profile over the shared protocol-4 register projection, backed by donor captures, user-confirmed controls, and the Protocol No. 3-10 documentation.
112
114
- Variants:
@@ -117,9 +119,17 @@ Runtime descriptors with no specific commercial model record. These are generic
0 commit comments