You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Commit 181386f
Browse filesBrowse the repository at this point in the historyBrowse files
Copy file name to clipboardExpand all lines: catalog/inverter_models/models/eybond_short_ascii_family.json
+6-4Lines changed: 6 additions & 4 deletions
Original file line number
Diff line number
Diff line change
@@ -28,21 +28,23 @@
28
28
"vendor_register_map": "partial",
29
29
"notes": [
30
30
"Runtime support is family-only and read-only. Compatible devices appear as EyeBond Short-ASCII family; retail model and serial are not inferred.",
31
-
"Optional RB/F/RH entities are disabled by default and expire on TTL or invalid replies."
31
+
"Optional RB/F/RH and aux-0200 MPPT/PV entities are disabled by default and expire on TTL or invalid replies."
32
32
]
33
33
},
34
34
"known_limitations": [
35
35
"Family identity only: no retail commercial model (including no Anern SPI-12000W claim) and no inverter serial from MP/Q1/MD.",
36
36
"Read-only: no inverter controls; Full Control does not invent settings.",
37
-
"Live PV power is absent; offline MPPT decode is maintainer-only and does not create HA entities.",
38
-
"Quiet fault/diagnostic sensors beyond the existing Q1 flags (Q2) are deferred; mppt_error waits on any future live-PV admission.",
37
+
"Optional live PV/MPPT uses the documented auxiliary 0200 runtime read only (not tip AABB harvest, not settings 0202). Matching schema sensors stay disabled by default; mppt_error_code is diagnostic and quiet. Samples use 30 s solicit / 60 s TTL; at most one optional read per Q1 cycle, with FC4 RB/F/RH preferred when both are due.",
38
+
"Offline decode_short_ascii_mppt is a maintainer capture inspector only; it is not the live optional admission path and does not create entities by itself.",
39
+
"Live PV/MPPT admission is code-complete but not yet live-qualified on site HA (family cutover / Support Archive RECEIPT still pending).",
40
+
"Quiet fault/diagnostic sensors beyond Q1 flags and the quiet mppt_error_code (Q2 extras) remain deferred.",
39
41
"estimated_ac_load_power is load% × rated VA from F — an estimate, not measured active power; load_percent stays separate. Output frequency is not grid frequency.",
40
42
"Optional BMS currents and battery_power publish only when RH reports BMS current display accuracy=1 (decimals) and F ratings are available for I/P hard-reject bounds; RH=0, unread, expired or failed RH omits those keys. RH=1 is the discriminator (no retail-model gate).",
41
43
"Impossible RB V/SoC/I/P values are hard-rejected. Link-loss (V=0 ∧ SoC=0) may hold last-good BMS for up to 180 s without refreshing sample age; normal RB TTL remains 60 s.",
42
44
"Diagnostic counters: bms_link_loss_count and rb_hard_reject_count are runtime-scoped; reading_hold_pending_count stays 0 (physics confirmation-hold deferred).",
43
45
"BMS current / battery_power path is SmartValue-correlated on one live family member; other members (e.g. Maxinn) are not separately live-proven and only light up if RH=1."
44
46
],
45
-
"knowledge_summary": "EyeBond Short-ASCII is a capture-qualified read-only family for the fixed MP/Q1/MD dialect shared by some Anern and Maxinn sites. Optional F/RH/RB add rated values and BMS telemetry with TTL expiry, hard-reject/link-loss hold, and an RH+F gate for currents. Labelled AC-load estimate is separate from measured battery DC power. Live PV and retail-model identity remain out of scope.",
47
+
"knowledge_summary": "EyeBond Short-ASCII is a capture-qualified read-only family for the fixed MP/Q1/MD dialect shared by some Anern and Maxinn sites. Optional F/RH/RB add rated values and BMS telemetry with TTL expiry, hard-reject/link-loss hold, and an RH+F gate for currents. Optional live PV/MPPT uses aux 0200 with opt-in entities and TTL; offline MPPT decode stays maintainer-only. Labelled AC-load estimate is separate from measured battery DC power. Retail-model identity remains out of scope; site live-qualification for the PV path is still pending.",
- Runtime support is family-only and read-only. Compatible devices appear as EyeBond Short-ASCII family; retail model and serial are not inferred.
266
-
- Optional RB/F/RH entities are disabled by default and expire on TTL or invalid replies.
267
-
- Summary: EyeBond Short-ASCII is a capture-qualified read-only family for the fixed MP/Q1/MD dialect shared by some Anern and Maxinn sites. Optional F/RH/RB add rated values and BMS telemetry with TTL expiry, hard-reject/link-loss hold, and an RH+F gate for currents. Labelled AC-load estimate is separate from measured battery DC power. Live PV and retail-model identity remain out of scope.
266
+
- Optional RB/F/RH and aux-0200 MPPT/PV entities are disabled by default and expire on TTL or invalid replies.
267
+
- Summary: EyeBond Short-ASCII is a capture-qualified read-only family for the fixed MP/Q1/MD dialect shared by some Anern and Maxinn sites. Optional F/RH/RB add rated values and BMS telemetry with TTL expiry, hard-reject/link-loss hold, and an RH+F gate for currents. Optional live PV/MPPT uses aux 0200 with opt-in entities and TTL; offline MPPT decode stays maintainer-only. Labelled AC-load estimate is separate from measured battery DC power. Retail-model identity remains out of scope; site live-qualification for the PV path is still pending.
268
268
- Variants:
269
269
-`urtu1920_checksum` — EyeBond Short-ASCII read-only family (URTU1920 checksum dialect)
- Family identity only: no retail commercial model (including no Anern SPI-12000W claim) and no inverter serial from MP/Q1/MD.
278
278
- Read-only: no inverter controls; Full Control does not invent settings.
279
-
- Live PV power is absent; offline MPPT decode is maintainer-only and does not create HA entities.
280
-
- Quiet fault/diagnostic sensors beyond the existing Q1 flags (Q2) are deferred; mppt_error waits on any future live-PV admission.
279
+
- Optional live PV/MPPT uses the documented auxiliary 0200 runtime read only (not tip AABB harvest, not settings 0202). Matching schema sensors stay disabled by default; mppt_error_code is diagnostic and quiet. Samples use 30 s solicit / 60 s TTL; at most one optional read per Q1 cycle, with FC4 RB/F/RH preferred when both are due.
280
+
- Offline decode_short_ascii_mppt is a maintainer capture inspector only; it is not the live optional admission path and does not create entities by itself.
281
+
- Live PV/MPPT admission is code-complete but not yet live-qualified on site HA (family cutover / Support Archive RECEIPT still pending).
282
+
- Quiet fault/diagnostic sensors beyond Q1 flags and the quiet mppt_error_code (Q2 extras) remain deferred.
281
283
- estimated_ac_load_power is load% × rated VA from F — an estimate, not measured active power; load_percent stays separate. Output frequency is not grid frequency.
282
284
- Optional BMS currents and battery_power publish only when RH reports BMS current display accuracy=1 (decimals) and F ratings are available for I/P hard-reject bounds; RH=0, unread, expired or failed RH omits those keys. RH=1 is the discriminator (no retail-model gate).
283
285
- Impossible RB V/SoC/I/P values are hard-rejected. Link-loss (V=0 ∧ SoC=0) may hold last-good BMS for up to 180 s without refreshing sample age; normal RB TTL remains 60 s.
0 commit comments