4 | 4 | "manufacturer": "Kevolt", |
5 | 5 | "model": "PD0080G-TPM-EU", |
6 | 6 | "aliases": [ |
7 | | - "Kevolt 80 kW Three-Phase Hybrid" |
| 7 | + "Kevolt 8 kW Three-Phase Hybrid" |
8 | 8 | ], |
9 | 9 | "lifecycle": "experimental", |
10 | 10 | "variants": [ |
11 | 11 | { |
12 | 12 | "variant_key": "deye_3ph_high_80kw", |
13 | | - "label": "Deye-compatible FC03 high-power map, protocol 0x0104, 80 kW", |
| 13 | + "label": "Deye-compatible FC03 high-power map, protocol 0x0104, 8 kW", |
14 | 14 | "device_descriptor_keys": [ |
15 | 15 | "deye_3ph_high_80kw" |
16 | 16 | ], |
|
21 | 21 | } |
22 | 22 | ], |
23 | 23 | "validation": { |
24 | | - "hardware": "captured", |
| 24 | + "hardware": "confirmed", |
25 | 25 | "telemetry": "partial", |
26 | 26 | "controls": "partial" |
27 | 27 | }, |
|
31 | 31 | "vendor_register_map": "documented", |
32 | 32 | "notes": [ |
33 | 33 | "The supplied SmartValue proxy capture contains repeated, CRC-valid Modbus FC03 request/response pairs for the Deye-compatible three-phase runtime map at registers 500-683.", |
34 | | - "Runtime identification uses four local raw anchors: device type 5, protocol version 0x0104, and low-first rated-power words 0x3880/0x0001 (80000 raw W).", |
35 | | - "The translated document labels the rated-power words as 0.1 W, but that scale conflicts with both the reported 80 kW hardware and its captured raw value 80000. Runtime therefore uses the hardware-correlated 1 W scale and fingerprints the unscaled words.", |
| 34 | + "Runtime identification uses four local raw anchors: device type 5, protocol version 0x0104, and low-first rated-power words 0x3880/0x0001 (80000 raw; documented 0.1 W scale = 8000 W).", |
| 35 | + "Direct hardware feedback confirms this is the 8 kW model, so the runtime now follows the protocol document's 0.1 W rated-power scale. The raw words remain the stable fingerprint anchors.", |
| 36 | + "Hardware feedback confirms the exposed battery values already use the expected negative-on-charge sign; the integration preserves that wire sign.", |
36 | 37 | "Runtime reads use small register blocks of at most 15 words rather than the unsupported 500-599 bulk read reported in the issue.", |
37 | 38 | "A bounded document-backed operational subset with unambiguous register encoding is available as 118 untested controls only in Full control mode. It covers battery, charging, generator, smart-load, export, metering, TOU, topology, and selected advanced functions.", |
38 | 39 | "Settings read-back is rotated one compact block per poll so the expanded control surface does not delay live telemetry. Every write uses FC 0x10, preserves unrelated shared-register bits, and requires an immediate wire read-back before it is accepted." |
|
41 | 42 | "known_limitations": [ |
42 | 43 | "All 118 document-backed controls are untested and disabled by default. Users must explicitly select Full control and then enable only the individual entities they intend to test.", |
43 | 44 | "Factory reset, production-test, EEPROM initialization, calibration, BMS-owned live words, parallel-cluster addressing, and grid-code/certification curves are intentionally not exposed as user controls even though they occupy writable registers in the protocol document.", |
44 | | - "Battery output power/current retain the documented wire sign as diagnostic values; their charge/discharge sign has not yet been promoted to canonical battery telemetry.", |
| 45 | + "Battery output power/current retain the hardware-confirmed wire sign; no additional canonical sign projection is inferred.", |
45 | 46 | "Heat-sink temperature is diagnostic because the observed raw value requires the offset-1000 convention used by adjacent Deye storage maps, while the translated table omits that offset for register 541.", |
46 | | - "The commercial Kevolt identity comes from the public issue report; the local fingerprint identifies the compatible 80 kW Deye-family wire layout and may be shared by OEM siblings.", |
| 47 | + "The commercial Kevolt identity comes from the public issue report; the local fingerprint identifies the compatible 8 kW Deye-family wire layout and may be shared by OEM siblings.", |
47 | 48 | "A current-release hardware retest is still required before telemetry support can be marked confirmed." |
48 | 49 | ], |
49 | | - "knowledge_summary": "Kevolt PD0080G-TPM-EU is a reported 80 kW three-phase hybrid inverter behind an EyeBond Wi-Fi collector. The latest SmartValue proxy capture proves a Modbus RTU FC03 layout with device type 5, protocol version 0x0104, rated-power words resolving to 80000 raw W, and live telemetry in the Deye-compatible 500-683 register range. Deye Modbus RTU V1.04 corroborates the telemetry and documents a broader FC 0x10 settings range. The exact wire fingerprint therefore exposes the current document-backed telemetry surface plus 118 opt-in, untested controls whose encodings are unambiguous, with shared-field-safe writes and mandatory immediate read-back confirmation.", |
| 50 | + "knowledge_summary": "Kevolt PD0080G-TPM-EU is a hardware-confirmed 8 kW three-phase hybrid inverter behind an EyeBond Wi-Fi collector. The latest SmartValue proxy capture proves a Modbus RTU FC03 layout with device type 5, protocol version 0x0104, rated-power words 80000 raw at the documented 0.1 W scale (8000 W), and live telemetry in the Deye-compatible 500-683 register range. Deye Modbus RTU V1.04 corroborates the telemetry and documents a broader FC 0x10 settings range. The exact wire fingerprint therefore exposes the current document-backed telemetry surface plus 118 opt-in, untested controls whose encodings are unambiguous, with shared-field-safe writes and mandatory immediate read-back confirmation.", |
50 | 51 | "source_keys": [ |
51 | 52 | "github_issue_15", |
52 | 53 | "proxy_capture_issue_15_20260811", |
53 | 54 | "documentation_deye_three_phase_modbus_high_map", |
54 | | - "maintainer_kevolt_control_readback_20260826" |
| 55 | + "maintainer_kevolt_control_readback_20260826", |
| 56 | + "maintainer_kevolt_hardware_feedback_20260827" |
55 | 57 | ] |
56 | 58 | } |
0 commit comments