You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Commit 597f946
Browse filesBrowse the repository at this point in the historyBrowse files
Maksym Shtembuliak
committed
fix: use neutral PI30 VMII identity and document Victor support
Copy file name to clipboardExpand all lines: catalog/inverter_models/models/powmr_4_2kw.json
+3-1Lines changed: 3 additions & 1 deletion
Original file line number
Diff line number
Diff line change
@@ -39,7 +39,9 @@
39
39
"The same inverter also responds to the local SmartESS 0925 Modbus map through the legacy EyeBond binary tunnel; the commercial model is PowMr 4.2kW, while the raw inverter model reports VMII-NXPW5KW."
40
40
]
41
41
},
42
-
"known_limitations": [],
42
+
"known_limitations": [
43
+
"The PI30 QMN identity VMII-NXPW5KW is shared with other commercial models and powers. Automatic detection uses the neutral PI30 VMII-NXPW5KW label; it does not uniquely identify PowMr or a 4.2 kW rating."
44
+
],
43
45
"knowledge_summary": "PowMr 4.2KW with raw model number VMII-NXPW5KW. The inverter supports PI30 ASCII and the local SmartESS 0925 Modbus runtime through the legacy EyeBond binary tunnel.",
"Uses the existing PI30 VMII profile; no new commands, transport or wider write ranges are introduced.",
27
+
"The owner confirmed Output Source Priority, Charge Source Priority and battery bulk, float, cut-off and recharge voltage controls on integration 0.1.53. Other controls and firmware variants are not confirmed by this report."
28
+
]
29
+
},
30
+
"known_limitations": [
31
+
"QMN reports the shared VMII-NXPW5KW identity, not a unique Victor retail model. Automatic detection therefore displays PI30 VMII-NXPW5KW; the public catalog records the owner-reported brand separately.",
32
+
"QVFW3 and optional QET/QLT/QT energy commands returned NAK in the supplied archive.",
33
+
"Hardware confirmation was supplied for integration 0.1.53; replay on current code does not replace a current-version hardware test."
34
+
],
35
+
"knowledge_summary": "Victor NM-PRO-6.2KW is confirmed by the issue #54 owner and support archive as a 6200 W / 48 V PI30 inverter using the shared VMII-NXPW5KW profile, with working telemetry and a specifically reported subset of controls.",
"title": "Victor NM-PRO-6.2KW PI30 archive and owner control report",
6
+
"reference": "project-issue:54",
7
+
"captured_at": "2026-09-30",
8
+
"visibility": "public",
9
+
"summary_publishable": true,
10
+
"summary": "The owner identifies the unit as Victor NM-PRO-6.2KW and reports working telemetry on integration 0.1.53. The archive records QPI=PI30, shared QMN=VMII-NXPW5KW, a 25-field QPIRI response rated 6200 W / 48 V, live QPIGS, QFLAG, QMOD and firmware replies. The owner explicitly confirms Output Source Priority, Charge Source Priority and battery bulk, float, cut-off and recharge voltage changes. The read-only archive itself is not a write trace, and the report does not qualify every inherited control or uniquely identify the brand from QMN.",
- Tier: full | Read-only: no | Profile: pi30_ascii/models/vmii_nxpw5kw.json | Schema: pi30_ascii/models/vmii_nxpw5kw.json
451
452
- Capabilities: 20 (tested 20); support tiers: standard 20 | Telemetry: 77 measurements, 16 binary sensors
452
-
- Known limitations: —
453
+
- Known limitations:
454
+
- The PI30 QMN identity VMII-NXPW5KW is shared with other commercial models and powers. Automatic detection uses the neutral PI30 VMII-NXPW5KW label; it does not uniquely identify PowMr or a 4.2 kW rating.
- Uses the existing PI30 VMII profile; no new commands, transport or wider write ranges are introduced.
536
+
- The owner confirmed Output Source Priority, Charge Source Priority and battery bulk, float, cut-off and recharge voltage controls on integration 0.1.53. Other controls and firmware variants are not confirmed by this report.
537
+
- Summary: Victor NM-PRO-6.2KW is confirmed by the issue #54 owner and support archive as a 6200 W / 48 V PI30 inverter using the shared VMII-NXPW5KW profile, with working telemetry and a specifically reported subset of controls.
538
+
- Variants:
539
+
-`pi30_vmii_nxpw5kw` — PI30 VMII-NXPW5KW, 25-field 6200 W / 48 V rating
- Tier: full | Read-only: no | Profile: pi30_ascii/models/vmii_nxpw5kw.json | Schema: pi30_ascii/models/vmii_nxpw5kw.json
545
+
- Capabilities: 20 (tested 20); support tiers: standard 20 | Telemetry: 77 measurements, 16 binary sensors
546
+
- Known limitations:
547
+
- QMN reports the shared VMII-NXPW5KW identity, not a unique Victor retail model. Automatic detection therefore displays PI30 VMII-NXPW5KW; the public catalog records the owner-reported brand separately.
548
+
- QVFW3 and optional QET/QLT/QT energy commands returned NAK in the supplied archive.
549
+
- Hardware confirmation was supplied for integration 0.1.53; replay on current code does not replace a current-version hardware test.
0 commit comments