docs: align cloud learning architecture with numeric probes
1 parent c18b03a commit c3550fe

1 file changed

Lines changed: 6 additions & 2 deletions

File tree

‎docs/architecture/CLOUD_LEARNING_ARCHITECTURE.md‎

Lines changed: 6 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -93,8 +93,12 @@ This confirms collector configuration, not cloud-service telemetry availability.
9393
DESSMonitor's [official API](https://api.dessmonitor.com/chapter5/ctrlDevice.html)
9494
documents `ctrlDevice`. The active engine authenticates and resolves an exact
9595
same-PN metadata bundle before opening the protected route, then sends only
96-
provider-declared choice values or the already-reported current value. It never
97-
invents a numeric value and excludes destructive-looking controls. Every action
96+
provider-declared choices or bounded numeric probes from the shared planner.
97+
Numeric probes use current values or optional provider hints when available,
98+
otherwise explicitly probe-only samples; they do not imply operating limits.
99+
Two distinct intercepted values must confirm the supported encoding before an
100+
ordinary learned numeric control can be generated. Destructive-looking controls
101+
remain excluded. Every action
98102
is matched only against writes observed after that action's exact route cursor;
99103
a successful cloud response without such an observation stops the run as a
100104
possible unproxied write. There is no fallback to SmartESS or ValueCloud.