Initial release. Developed against a live TED5000 with the solar package, 2 MTUs (Grid + Solar) and 4 Spyders (23 wired circuits).
- Net / consumption / solar power, energy and cost sensors
- Per-MTU power, voltage, power factor, apparent power
- Per-circuit (Spyder) power and energy, named from the gateway config, skipping groups with no CT assigned
- Utility rate, projected bill, days left in billing period
- Energy dashboard support (total_increasing kWh sensors)
- Config flow with optional credentials, options for polling interval and per-circuit energy sensors, diagnostics
- Uses the endpoints modern TED5000 firmware actually serves, rather than
the
LiveData.xmlendpoint the built-in integration requires
- Added line-to-line (~240 V) voltage sensors for the gateway and each MTU, derived from the reported leg voltage (auto-detects whether the MTU is wired line-to-neutral or line-to-line)
- Existing voltage sensors relabelled "(leg)" for clarity
- Integration renamed to simply "TED5000 Pro"
- Phantom (standby) load tracking: nightly quiet-window minimum, rolling average over a configurable number of days, and its monthly cost at the current utility rate
- History persists across restarts; wrapping windows (e.g. 23:00-05:00) are treated as a single night
- New options: phantom days to average, quiet window start and end