312 | 312 | 254: {"name": "voltage_delta_hysteresis", "unit": "V", "scale": 0.1, "desc": "Voltage delta/hysteresis", "min": 0, "max": 100}, |
313 | 313 | 260: {"name": "bus_voltage_high_limit", "unit": "V", "scale": 0.1, "desc": "Bus voltage high limit", "min": 0, "max": 800}, |
314 | 314 | 261: {"name": "discharge_recovery", "unit": "%", "scale": 1.0, "desc": "Discharge recovery", "min": 0, "max": 100}, |
| 315 | + |
| 316 | + # ── Function-enable bitfields (21, 110, 120, 179) ── |
| 317 | + # These pack many on/off toggles into a single 16-bit register. They are |
| 318 | + # writable, but the UI should present them as bit toggles, not raw numbers. |
| 319 | + 21: {"name": "function_enable_1", "unit": "", "scale": 1.0, "desc": "Function enable 1 (bitfield: EPS, derate, DRMS, LVRT, anti-island, neutral detect, soft start, AC charge, seamless switch, standby, forced dischg/chg, ISO, GFCI, DCI, grid export)", "min": 0, "max": 65535}, |
| 320 | + 110: {"name": "function_enable_3", "unit": "", "scale": 1.0, "desc": "Function enable 3 (bitfield: PV grid-off, fast zero-export, micro-grid, battery shared, charge-last, CT sample ratio, buzzer, PV CT type, take-load-together, on-grid mode, green/eco mode)", "min": 0, "max": 65535}, |
| 321 | + 120: {"name": "system_enable_2", "unit": "", "scale": 1.0, "desc": "System enable 2 (bitfield of system-level toggles)", "min": 0, "max": 65535}, |
| 322 | + 179: {"name": "function_enable_4", "unit": "", "scale": 1.0, "desc": "Function enable 4 (bitfield of function toggles)", "min": 0, "max": 65535}, |
| 323 | + |
| 324 | + # ── Optimal charge/discharge time marks (126-131) ── |
| 325 | + # Each register packs 8 half-hour marks (00:00-03:30, etc.). Each mark is |
| 326 | + # 2 bits: 0=no op, 1=AC charge, 2=PV charge, 3=discharge. |
| 327 | + 126: {"name": "optimal_chg_dischg_0_3", "unit": "", "scale": 1.0, "desc": "Optimal charge/discharge marks 00:00-03:30 (2 bits per half-hour: 0=off, 1=AC chg, 2=PV chg, 3=dischg)", "min": 0, "max": 65535}, |
| 328 | + 127: {"name": "optimal_chg_dischg_4_7", "unit": "", "scale": 1.0, "desc": "Optimal charge/discharge marks 04:00-07:30", "min": 0, "max": 65535}, |
| 329 | + 128: {"name": "optimal_chg_dischg_8_11", "unit": "", "scale": 1.0, "desc": "Optimal charge/discharge marks 08:00-11:30", "min": 0, "max": 65535}, |
| 330 | + 129: {"name": "optimal_chg_dischg_12_15", "unit": "", "scale": 1.0, "desc": "Optimal charge/discharge marks 12:00-15:30", "min": 0, "max": 65535}, |
| 331 | + 130: {"name": "optimal_chg_dischg_16_19", "unit": "", "scale": 1.0, "desc": "Optimal charge/discharge marks 16:00-19:30", "min": 0, "max": 65535}, |
| 332 | + 131: {"name": "optimal_chg_dischg_20_23", "unit": "", "scale": 1.0, "desc": "Optimal charge/discharge marks 20:00-23:30", "min": 0, "max": 65535}, |
| 333 | + |
| 334 | + # ── Grid regulation / meter / LCD (203, 225, 230, 251) ── |
| 335 | + 203: {"name": "grid_regulation", "unit": "", "scale": 1.0, "desc": "Grid regulation settings (bitfield)", "min": 0, "max": 65535}, |
| 336 | + 225: {"name": "lcd_password", "unit": "", "scale": 1.0, "desc": "LCD advanced-page password", "min": 0, "max": 65535}, |
| 337 | + 230: {"name": "meter_config", "unit": "", "scale": 1.0, "desc": "Meter config (meter count, measure type, install phase)", "min": 0, "max": 65535, "capabilities": {"wattnode"}}, |
| 338 | + 251: {"name": "wattnode_ct_directions", "unit": "", "scale": 1.0, "desc": "WattNode CT direction and frequency settings (bitfield)", "min": 0, "max": 65535, "capabilities": {"wattnode"}}, |
| 339 | + |
| 340 | + # ── Generator start/end times (256-259) — GENERATOR capability ── |
| 341 | + 256: {"name": "generator_start_time", "unit": "time", "scale": 1.0, "desc": "Generator start time (hour+minute)", "min": 0, "max": 2359, "capabilities": {"generator"}}, |
| 342 | + 257: {"name": "generator_end_time", "unit": "time", "scale": 1.0, "desc": "Generator end time (hour+minute)", "min": 0, "max": 2359, "capabilities": {"generator"}}, |
| 343 | + 258: {"name": "generator_start_time_1", "unit": "time", "scale": 1.0, "desc": "Generator period 1 start time (hour+minute)", "min": 0, "max": 2359, "capabilities": {"generator"}}, |
| 344 | + 259: {"name": "generator_end_time_1", "unit": "time", "scale": 1.0, "desc": "Generator period 1 end time (hour+minute)", "min": 0, "max": 2359, "capabilities": {"generator"}}, |
| 345 | + |
| 346 | + # ── Intentionally NOT exposed as writable (read-only or dangerous) ── |
| 347 | + # 7-10 firmware/version codes (read-only) |
| 348 | + # 11 reset (dangerous — restarts inverter) |
| 349 | + # 12-14 inverter clock (dangerous — changing time disrupts operation) |
| 350 | + # 16 language + device type (read-only, used for model detection) |
| 351 | + # 19 device type high-speed (read-only) |
| 352 | + # 113 set composed phase (write-only) |
| 353 | + # 114 clear parallel alarm (write-only) |
| 354 | + # 224 LCD config (read-only) |
| 355 | + # 231 reset G100 lockout (dangerous) |
| 356 | + # 241 permit service (dangerous) |
| 357 | + # 244-245 bootloader/flash (read-only) |
| 358 | + # 500-723 7-day scheduling — requires WriteMultipleRegisters (0x10), |
| 359 | + # which lux-mon does not implement yet. Deferred. |
315 | 360 | } |
316 | 361 |
|
317 | 362 | # Friendly display labels matching the reference portal's terminology. |
|