MIN/TLX Inverter Settings

This is part of the OpenAPI V1 doc.

For MIN/TLX systems, the public V1 API provides a more robust way to read and write inverter settings:

  • Read Parameter

    • function: api.min_read_parameter
    • parameters:
      • device_sn: The device serial number
      • parameter_id: Parameter ID to read (e.g., "discharge_power")
      • start_address, end_address: Optional, for reading registers by address
  • Write Parameter

    • function: api.min_write_parameter
    • parameters:
      • device_sn: The device serial number
      • parameter_id: Parameter ID to write (e.g., "ac_charge")
      • parameter_values: Value to set (single value, list, or dictionary)
  • Time Segments

    • function: api.min_write_time_segment
    • parameters:
      • device_sn: The device serial number
      • segment_id: Segment number (1-9)
      • batt_mode: Battery mode (0=Load First, 1=Battery First, 2=Grid First)
      • start_time: Datetime.time object for segment start
      • end_time: Datetime.time object for segment end
      • enabled: Boolean to enable/disable segment
  • Read Time Segments

    • function: api.min_read_time_segments
    • parameters:
      • device_sn: The device serial number
      • settings_data: Optional settings data to avoid redundant API calls