Development Log

This document is a short, GitHub-friendly summary of the raw research notes and project files in this folder.

2025 - Research and Concept Phase

October 2025

  • The project direction was defined around rapid prototyping and learning through a working physical system rather than abstract specification alone.
  • The main focus became a bilateral haptic connection in which movement and resistance can be perceived mutually.
  • Visits to OORI and related institutional contexts reinforced the idea that small-scale, sensitive, therapist-adjacent systems may be more relevant than large industrial-style robotics.

November 2025

  • The rehabilitation context became clearer.
  • The project started to take shape as a research platform rather than a finished device.

2026 - Hardware and Software Development

January 2026

  • Component sourcing and technical selection began.
  • Main components included:
    • ESP32-based 20A FOC board
    • BLDC motors
    • programming interface, jumpers, and connectors
    • external power supply
  • Early research focused on SimpleFOC, ESP32, gate driver mapping, and current sensing options.

February 1-2, 2026

  • The fixed board GPIO mapping was identified.
  • The first stable open-loop motor spin was successful.
  • Key lesson: the gate driver pins on this board are not freely assignable, so correct pin mapping is critical.

Validated open-loop configuration:

Function Pin / value
Phase A GPIO16
Phase B GPIO17
Phase C GPIO5
Enable GPIO4
Power supply 24V test environment
PWM frequency 40 kHz

February 3, 2026

  • The PWM and Enable mapping was fully verified.
  • The board's current sensing capabilities were also documented.
  • ESP-NOW communication setup began, including recording the MAC addresses of both boards.

Recorded current sensing data:

Item Value
Type inline current sensing
Shunt 0.01 Ohm
Gain 50
Phase A ADC GPIO39
Phase B ADC GPIO36

February 4-12, 2026

  • Iterative experiments continued around motors, wiring, and stability.
  • ESP32 core and library compatibility issues were addressed.
  • The fundamentals of closed-loop operation were checked in a one-motor / one-controller setup.

February 13, 2026

  • The first stable bilateral mirror system was achieved.
  • The two ESP32 boards exchanged angle data in real time over ESP-NOW.
  • The system produced a mutual physical resistance sensation.
  • The first working version was published to GitHub.

What the February 2026 Sketch Implemented

The historical v2 code:

  • reads the local motor angle
  • sends it to the other board
  • receives the remote angle
  • generates a spring-like torque from the angle difference
  • falls back to zero torque if the link is lost

This is not a rigid position-following system. It is a haptic coupling strategy designed to create a mutually perceivable physical connection.

Important Note

The research notes also describe current sensing and additional closed-loop possibilities at the platform level, but the February 2026 sketch primarily documents a sensor-based SimpleFOC and ESP-NOW mirror behavior. It is now preserved under firmware/legacy/; the current MKS Mega firmware is firmware/MKS_Parallel_Mirror/MKS_Parallel_Mirror.ino.

July 14, 2026 - MKS ESP32 FOC Mega Port

The bilateral controller was ported to and tested on two Makerbase MKS ESP32 FOC Mega boards with iPower GM3506 motors and AS5048A SPI encoders.

Validated configuration:

Item Value
Motor PWM GPIO32 / GPIO33 / GPIO25
Motor enable GPIO12
AS5048A SPI SCK 18 / MISO 19 / MOSI 23 / CS 5
Motor pole pairs 11 (24N / 22P)
ESP-NOW update period 4 ms
Measured packet age typically 1-4 ms
Control voltage limit 0.25 V

Stored FOC calibration was verified on both nodes. Bidirectional haptic coupling was tested from each motor, with the final reverse-direction test settling to about 0.04 rad of position difference without a protection trip.

The MKS firmware also includes link timeout, speed and following-error limits, torque slew limiting, automatic disarm, and a 150 ms zero-position synchronization window. The synchronization window prevents a stale packet from causing a false following-error trip when the two nodes are armed sequentially.

The M0 inline current-sense circuit was verified from the official Makerbase schematic and on the physical boards. It uses 10 mOhm shunts, INA240A2 amplifiers with gain 50, and ESP32 ADC inputs GPIO39 / GPIO36. Measured zero-current reference levels were about 1685 mV on node A and 1676 mV on node B. During a bilateral load test, the held peak currents were 0.204 A and 0.176 A; steady holding current was approximately 0.05-0.07 A.

The first current-monitored firmware retained voltage-mode torque control, monitored both measured phases, reconstructed the third phase, and disarmed after sustained phase current above 0.75 A. A standalone non-switching ADC test is available in firmware/MKS_Current_Sense_Diagnostic/.

Autonomous foldback prototype

The controller was subsequently changed from manually armed, latched motion protection to autonomous startup and continuous foldback regulation. Both nodes now arm without a USB host after a 1.5 s peer synchronization period. Position error is bounded before entering the spring model, drive torque fades between 4-7 rad/s, and phase-current foldback acts between 0.30-0.50 A. A real radio timeout still disables the power stage and initiates automatic recovery when the link returns.

The first loaded test of the 1.2 V control profile reached held peak currents of 0.360 A on node A and 0.441 A on node B. Current foldback intervened on both nodes, neither node latched off, and both returned to near-zero position and torque after release. The configured 7 V value is the power-stage ceiling, not an unconditional motor torque command.

Mega RGB hardware erratum

Macro photographs identified the indicator between the sensor connectors as an XL-3528RGBW-WS2812B. RMT tests covered standard WS2812 timing, the Xinglight datasheet timing, and alternate free GPIOs on both boards without producing light. Static probing then confirmed that GPIO2 reaches the package's top-left VDD lead, while the top-right DI lead is permanently at 3.3 V. The PCB footprint swaps the LED supply and data nets on both tested boards. This cannot be corrected in firmware; the upper leads must be lifted and cross-wired, or an external status LED must be used. After the hardware fault was established, the standalone RGB diagnostic and the inactive LED driver code were removed from the current firmware. Serial telemetry remains the supported status interface.

Input-voltage calibration

The boot-time voltage monitor was calibrated with the motors stopped against multimeter readings taken directly at each board's green power input. Node A reported 11.55 V at an actual 11.25 V; node B reported 12.71 V at an actual 12.42 V. The resulting individual divider factors (8.279 and 8.306) agree within 0.33%, so the shared VIN_SCALE was changed from 8.50 to 8.29. Expected readings after calibration are approximately 11.27 V and 12.40 V for the same input voltages.

Motion refinement

The first feel-oriented refinement removes the 0.10 V discontinuity at the edge of the position deadband. Static-friction compensation now rises smoothly over 0.060 rad, reducing the center notch while retaining useful breakaway torque. Each node also transmits its filtered velocity and applies damping to the relative velocity between the two motors. Common motion therefore receives less drag, while rapid opposing motion receives additional damping.

The first dynamic test of this revision reached 17.75 rad/s. Current foldback kept the observed peaks to 0.435 A on node A and 0.497 A on node B without latched shutdown, and the mechanism settled with about 0.04 rad position difference. At that small residual error the position integrator could still build repeating correction pulses. Integration is therefore enabled only above 0.10 rad; below that threshold its contribution decays at 0.80 V/s. The foldback counter now counts entries into limiting rather than control-loop iterations spent limiting.

A subsequent one-sided load test held node A while node B moved. Neither node latched off; measured peaks were 0.391 A and 0.427 A. The near-center torque remained steady after release, confirming that the integrator pulse was removed. The test also exposed rapid soft-limit crossings caused by using raw instantaneous phase-current samples. Foldback now uses a peak envelope with immediate attack, an 80 ms release time constant, and 0.95 / 0.99 entry/exit hysteresis. A raw sample at or above the 0.50 A hard limit still commands zero drive immediately.

The repeated one-sided hold test validated the envelope: each node recorded one foldback entry instead of hundreds of threshold crossings. Peak phase currents were 0.391 A on node A and 0.425 A on node B, with no hard-limit event, latched shutdown, or communication disturbance. This foldback behavior is the new baseline for subsequent feel and force-profile tuning.

Synchronized force profiles

The controller now provides gentle, normal, and strong profiles. Normal is the autonomous startup default and retains the validated 1.20 V behavior. Gentle reduces command voltage, virtual spring strength, friction compensation, and integral action. Strong raises the command ceiling to 1.60 V and increases spring and damping gains, while retaining the same measured 0.30-0.50 A current envelope. Serial commands g, n, and s select profiles during development. The selected profile is included in every ESP-NOW packet; torque is held at zero whenever the two nodes disagree, preventing asymmetric gains.

The first direct normal-to-strong comparison completed without a hard-current event, latched shutdown, or communication fault. Normal reached 0.408 A on node A and 0.412 A on node B, with a final relative position error of about 0.073 rad. Strong reached 0.453 A and 0.425 A; it added one foldback entry on A and eleven on the actively loaded B, and settled at about 0.057 rad relative error. The hand-driven trajectories were not identical, so this is a safety and behavior validation rather than a calibrated force comparison. Runtime profile selection now resets peak-current, foldback-event, and dynamic scaling telemetry so later profile tests start from clean counters.

Structured strong-profile motion test

A roughly three-minute structured test covered slow one-sided following in both directions, release and settling, resisted motion, common-mode motion, and rapid short reversals. Node A reached 0.439 A with 15 foldback entries; node B reached 0.453 A with 24 entries. Neither node reached the 0.50 A hard-current threshold, disarmed unexpectedly, or lost its peer. Packet age remained mostly within 0-4 ms, with an observed isolated 6 ms sample. During the rapid reversal section node B reached approximately 8.35 rad/s; the speed scale fell to zero as designed, so the controller stopped adding drive above its configured speed envelope. After release, the two reported positions differed by about 0.067 rad and the remaining correction command was approximately 0.06 V. The test validates the strong profile for continued prototype tuning, while the foldback counts show that repeated fast reversals are already using the intended soft current boundary.

Subjective evaluation found no vibration, but detected a slightly stepped, deliberate return when one motor was held, the other displaced, and then released. To make the elastic link more immediate without raising its current envelope, the position deadband was reduced from 0.035 to 0.025 rad and the normal torque slew rate increased from 3 to 6 V/s. Strong-profile spring gain increased from 1.55 to 2.00, friction compensation from 0.13 to 0.15 V, and integral gain from 0.20 to 0.24. Local viscous damping was reduced to 0.020, while relative coupling damping increased to 0.040, aiming for less common-motion drag and a tighter connection between opposing motions. The 0.30-0.50 A current foldback envelope remains unchanged.

Free-motion evaluation described the revised response as substantially livelier and more natural, with some remaining stepped feel and a still-deliberate return from large angular offsets. The test reached short raw-current peaks of 0.540 A and 0.524 A, with 39 and 37 foldback entries but no unexpected disarm or link fault. Since measured packet age remained around 0-4 ms, communication was not identified as the primary source of the stepped feel; motor cogging, voltage-mode torque control, and repeated foldback remain likely contributors. As a final low-risk refinement, the ESP-NOW period was reduced from 4 to 2 ms, the velocity filter time constant from 30 to 20 ms, and the spring exponent from 1.35 to 1.20. This increases update continuity and medium-to-large-error spring force without raising the 1.60 V strong-profile command ceiling or the configured current envelope.

The next evaluation found little force difference between approximately 20 and 200 degrees. Inspection showed that control error was intentionally clamped at 0.9 rad (52 degrees), and the strong voltage curve saturated near the same point. The strong profile now uses a progressive virtual spring: its ordinary spring section extends to 0.9 rad, followed by a quadratic end-stop term that reaches full force at 3.5 rad (about 200 degrees). The strong ceiling is 2.20 V; its reduced base gain preserves low-angle compliance while the end-stop becomes increasingly difficult to wind farther. The GM3506 vendor lists a 1 A load-current point at 12 V; the prototype remains below this, with soft/hard phase-current thresholds cautiously raised to 0.40 / 0.65 A. This higher-force mode still requires short tests and manual temperature checks because the boards do not measure motor winding temperature.

The first progressive-end-stop test remained below the new hard threshold: node A peaked at 0.461 A and node B at 0.546 A. The soft foldback envelope recorded 150 and 64 entries during repeated winding and return, with no link fault or unexpected disarm. The final reported position difference was about 0.006 rad (0.34 degrees). This is the final validated firmware state for the day; longer-duration thermal validation is still required before treating the higher-force strong profile as a continuous-duty operating mode.

Subjectively, the progressive curve produced the intended convincing spring feel up to roughly 200 degrees. Beyond that point and over multiple turns the return became slower and felt fatigued. This matches the present design: the virtual end-stop reaches full command and control error is capped at 3.5 rad, while sustained multi-turn motion invokes speed and current foldback. Multi-turn operation is outside the expected working range, but remains a tracked edge case. Future work should define an explicit travel policy and add thermal or energy-budget derating rather than merely increasing current further.

No perceptible motor heating, vibration, or abnormal motion noise was observed during the short progressive-spring and multi-turn edge-case tests. This is a positive qualitative result, but does not replace the planned instrumented continuous-duty thermal test.

Software thermal-load estimate

The controller now adds a non-latching long-duration protection layer based on an exponentially filtered phase-current-squared estimate. Its 45 s time constant preserves short force peaks while approximating sustained winding load. The resulting torque scale fades between 0.45 A and 0.60 A estimated thermal current and automatically recovers as the estimate cools. Telemetry reports thermalA and thermalScale. This is deliberately conservative and is not a substitute for a physical winding or driver temperature sensor.

A six-minute mixed endurance test exercised continuous 30-90 degree motion, alternating held offsets, and brief 150-200 degree excursions. Node A reached 0.628 A and 148 fast-foldback entries; node B reached 0.619 A and 240 entries, both remaining below the 0.65 A hard threshold. At shutdown the thermal-current estimates were approximately 0.126 A and 0.124 A, with thermalScale=1.00 on both nodes. Neither motor nor power board felt perceptibly warm, and no abnormal noise, vibration, link fault, or unexpected disarm was observed. This validates the estimator under representative short-duration use; the checklist's instrumented 10-15 minute continuous-duty test remains open.

Persistent operating profile

The selected gentle, normal, or strong profile is now stored in ESP32 NVS and restored before radio startup. A standalone power cycle therefore returns both nodes to their last selected behavior without a USB host. Flash is written only when the profile actually changes. Invalid stored values fall back to normal, and the existing peer-profile agreement check continues to suppress torque if the two boards restore different profiles.

After charging, a fresh boot measured 12.47 V on node A against 12.48 V at the input with a multimeter; node B measured 12.41 V. The resulting startup estimates of 94% and 91% agreed with the charger's roughly 90% indication. Earlier lower percentages were stale pre-charge boot readings, confirming that the voltage calibration is sound and that the documented boot-only limitation, not scale error, caused the apparent discrepancy.

Startup and peer compatibility hardening

Automatic startup is now inhibited below the existing conservative 11.1 V minimum rather than only below the absolute 10.5 V empty-pack endpoint. Every ESP-NOW packet also carries an explicit protocol version. Packets from an incompatible firmware version are discarded before updating peer state, so a partial firmware update cannot produce torque between mismatched controllers. Telemetry reports both local and peer protocol versions.

The compatibility guard was validated with a staged update. After updating only node A, it remained armed=0 with ageMs=never, rx=0, and peerProtocol=0 while node B still ran the prior packet format. Once B was updated, both nodes reported protocol=1, peerProtocol=1, restored their persisted strong profile, and resumed normal 0-2 ms peer communication.

Coordinated run intent

Protocol version 2 adds an explicit run-enabled flag. A manual stop issued to either node propagates to its peer and disables both power stages. Starting one node gives it a short local synchronization window; the peer follows only the stopped-to-running edge, avoiding a start request that could echo indefinitely. A valid edge clears the coordinated stop latch and permits peer-synchronized automatic arming. A node below the boot-voltage threshold cannot be restarted by its peer and propagates its stopped run intent to the healthy node.

The coordinated state machine was validated on both powered motor controllers. With both nodes armed, sending x only to A produced manual stop on A and peer stop on B, with both reporting armed=0 and auto=0. Sending a only to B then restored both nodes to armed=1, auto=1, and cleared A's manual stop latch. Finally, sending x only to B propagated peer stop to A. Both drivers were left disabled after the test; peer packet age remained typically 1-3 ms throughout.

Rejected directional travel-policy experiment

An experimental strong-profile policy added outward velocity damping from 2.8 rad to 3.5 rad and retained a 30% return-drive floor near the boundary. It did not produce a meaningful subjective improvement over the established progressive spring, but introduced a position-periodic clicking sensation. The experiment was therefore removed and the previous validated spring controller restored without increasing voltage or current limits.

The first bidirectional 90/160/180-200 degree hand test completed without an unexpected disarm. Node A reached 0.481 A and 194 current-foldback entries; node B reached 0.631 A and 75 entries, remaining just below the 0.65 A hard threshold. Post-test thermal estimates were approximately 0.18 A and 0.16 A with thermalScale=1.00, so no long-duration derating was active. Both nodes were stopped through the coordinated stop command after collecting telemetry. The result is retained here as a rejected experiment rather than a validated control change.

After restoring the prior controller on both nodes, the same slow bidirectional 0-200 degree sweep no longer produced the periodic clicking sensation. Peak currents also fell to 0.437 A on A and 0.511 A on B, compared with 0.481 A and 0.631 A during the rejected experiment. The rollback is therefore the current validated firmware state. Both nodes were left in coordinated stop.

Bidirectional reset recovery

One-sided controller resets were validated in both directions while the peer remained powered and armed. Resetting A caused B to disable on link timeout; resetting B likewise caused A to disable, with the first sampled stopped status showing ageMs=264 against the 250 ms timeout. During each peer reboot the healthy node remained disabled. After compatible packets resumed, both nodes re-zeroed, armed locally, waited for peer arm, and returned to synchronized operation without manual intervention. A coordinated stop was issued after the test. This establishes the fault-recovery baseline needed before raising the strong-profile output.

Experimental boost profile

Protocol version 3 adds a manually selected boost profile while retaining the validated strong profile unchanged. Boost uses the same progressive spring shape with a 2.50 V command ceiling, slightly higher base spring gain, and a profile-specific 0.45-0.70 A fast current-foldback envelope. The existing software thermal estimator and 0.45-0.60 A sustained-load derating remain unchanged and retain final authority. Boost is selected with b on both nodes and deliberately is not persisted to NVS, so the next standalone boot returns to the last validated gentle, normal, or strong profile.

The first 30-45 s boost hand test completed without an unexpected disarm. Node A peaked at 0.418 A with no foldback entry; node B peaked at 0.555 A with 24 foldback entries, remaining well below the boost 0.70 A hard limit. Thermal estimates were approximately 0.15 A on both nodes with thermalScale=1.00. The test ended with a coordinated stop. Subjective force, smoothness, noise, and temperature feedback are still required before boost is promoted beyond experimental status.

The first subjective boost tests reported a repeatable position-periodic click, approximately seven events over 180 degrees, while the lower strong profile remained smooth. The GM3506 encoder variant is consistently specified as 24N/22P, so the configured 11 pole pairs remain correct. A follow-up boost experiment changes FOC modulation from space-vector PWM to sine PWM to target low-speed commutation torque ripple without raising voltage or current limits.

The sine-PWM comparison reduced the subjective ripple from roughly seven to five or six weaker clicks over 180 degrees. Peak currents remained moderate at 0.514 A and 0.589 A. Inspection of SimpleFOC 2.4.0 then showed that the existing c command reused the configured electrical zero instead of measuring it again. The command now explicitly clears the offset, retains the validated CCW sensor direction, and performs a fresh offset alignment at 1.5 V before printing the measured value. This enables a controlled per-motor electrical-zero recalibration before further boost tuning.

Two forced measurements per motor were repeatable: A returned 0.634301 and 0.625865 rad; B returned 5.947243 and 5.934587 rad. Their mechanical spread was only about 0.04-0.07 degrees. Firmware protocol version 4 stores the pairwise means, 0.630083 rad for A and 5.940915 rad for B. Compared with the previous stored values, the corrections are about 1.38 degrees and 1.65 degrees mechanical respectively, large enough to plausibly explain why commutation ripple became apparent only in the higher-output boost profile.

The protocol-4 boost retest with the averaged electrical-zero values produced a noticeably faster return and made the remaining position-periodic clicking less intrusive, although it did not remove it completely. No meaningful motor or controller heating, vibration, or abnormal noise was observed. Post-test telemetry showed peak currents of 0.558 A on A and 0.574 A on B, with only 33 and 22 current-foldback entries. Thermal estimates had already decayed to approximately 0.08 A and 0.06 A; both nodes retained thermalScale=1.00. This confirms that the revised offsets are an improvement and that the current thermal policy still has comfortable margin. Both nodes were left in coordinated manual stop. The residual click should next be investigated as low-speed commutation/control ripple rather than addressed by raising the current ceiling alone.

With both drivers disabled, neither motor exhibited the clicking during a manual rotation. The effect is therefore generated by active commutation, not by passive magnetic cogging or the mechanism. Protocol version 5 begins an isolated PWM-frequency comparison at the ESP32 MCPWM backend's supported maximum of 40 kHz, up from 25 kHz. Sine PWM, calibrated electrical offsets, control gains, voltage ceilings, and current/thermal limits remain unchanged.

The 40 kHz comparison reduced the subjective click count from five or six to roughly two over 180 degrees. The remaining events changed position and count with hand speed, ruling out a fixed rotor-angle defect. Telemetry recorded 12 soft current-foldback entries on A and 34 on B, despite modest peaks of 0.541 A and 0.580 A and thermal estimates near 0.11 A. Protocol version 6 therefore raises only the experimental boost soft-current threshold from 0.45 A to 0.52 A. The 0.70 A hard ceiling and all sustained thermal limits remain unchanged, allowing a direct test of whether repeated soft foldback was producing the residual tactile steps.

The protocol-6 hand test felt more continuous overall, with the clearest improvement at higher hand speed. Repeated subjective comparisons had reached the point of tester fatigue, so no finer ranking is claimed. Peak currents were 0.663 A on A and 0.653 A on B, below the unchanged 0.70 A hard limit; thermal estimates were only about 0.07-0.08 A with no thermal derating. Soft foldback entries fell to 13 and 21. Both nodes were stopped. Further tuning will use a repeatable logged A/B procedure instead of relying on many consecutive free-form hand comparisons.

Supervised handoff build

Protocol version 7 packages the latest validated tactile configuration for a same-day supervised handoff. Handoff mode ignores profile values left in NVS, locks both nodes to boost, increases the automatic startup delay to 5 seconds, disables calibration/manual-zero/profile commands, and enforces a 10-minute session limit. A runtime ESP-NOW timeout or peer stop now latches both nodes off; normal operation resumes only after both controllers are fully power-cycled (or an explicit development serial start). A forced one-node reset confirmed that the healthy peer entered stopLatch=1 on link timeout and did not re-arm when communication returned. Initial protocol-7 startup was also verified with both nodes armed, matched, and idle at 11.69 V and 11.68 V respectively.