Expand Up @@ -150,11 +150,27 @@ def update(self, lp: Loadpoint) -> None:
s["/Status"] = status
s["/Connected"] = 1

# Cumulative counters only refreshed while connected. UNVERIFIED:
# chargedEnergy is treated as Wh (-> /1000 = kWh). Must be confirmed
# against a real EVCC /api/state sample before deploy.
# chargeTotalImport is EVCC's cumulative kWh meter value. It keeps
# increasing for IntegratedDevice loadpoints (heatpump, sgready-
# relay, …) where chargedEnergy stays at 0 because EVCC has no
# session semantics for "always connected" chargers. Fall back to
# chargedEnergy / 1000 when the meter value is missing.
total_import = float(lp.charge_total_import or 0.0)
if total_import > 0:
candidate = total_import
elif status != STATUS_DISCONNECTED:
candidate = float(lp.charged_energy) / 1000.0
else:
candidate = None

if candidate is not None:
# /Ac/Energy/Forward must be monotonic for VRM. Guard against
# transient source switches (e.g. EVCC briefly returning
# chargeTotalImport: null) rolling the counter backwards.
previous = float(s["/Ac/Energy/Forward"] or 0.0)
s["/Ac/Energy/Forward"] = max(candidate, previous)

if status != STATUS_DISCONNECTED:
s["/Ac/Energy/Forward"] = float(lp.charged_energy) / 1000.0
s["/ChargingTime"] = int(lp.charge_duration_ns) // 1_000_000_000

idx = (int(s["/UpdateIndex"]) + 1) % 256
Expand Down
2 changes: 2 additions & 0 deletions evcc_api.py
Original file line number Diff line number Diff line change
Expand Up @@ -26,6 +26,7 @@ class Loadpoint:
charge_voltages: List[float] = field(default_factory=lambda: [230.0, 230.0, 230.0])
effective_max_current: int = 16
charged_energy: float = 0.0
charge_total_import: float = 0.0
charge_duration_ns: int = 0


Expand Down Expand Up @@ -61,6 +62,7 @@ def _parse_loadpoints(state: dict) -> List[Loadpoint]:
charge_voltages=_normalize_triple(raw.get("chargeVoltages"), 230.0),
effective_max_current=int(raw.get("effectiveMaxCurrent") or 16),
charged_energy=float(raw.get("chargedEnergy") or 0.0),
charge_total_import=float(raw.get("chargeTotalImport") or 0.0),
charge_duration_ns=int(raw.get("chargeDuration") or 0),
))
return out
Expand Down
1 change: 1 addition & 0 deletions tests/fixtures/evcc_state_1lp.json
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,7 @@
"chargeVoltages": [230, 230, 230],
"effectiveMaxCurrent": 20,
"chargedEnergy": 250.0,
"chargeTotalImport": 12.345,
"chargeDuration": 600000000000
}
]
Expand Down
3 changes: 3 additions & 0 deletions tests/fixtures/evcc_state_3lp.json
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,7 @@
"chargeVoltages": [230, 230, 230],
"effectiveMaxCurrent": 16,
"chargedEnergy": 0.0,
"chargeTotalImport": 1.234,
"chargeDuration": 0
},
{
Expand All @@ -22,6 +23,7 @@
"chargeVoltages": [230, 230, 230],
"effectiveMaxCurrent": 20,
"chargedEnergy": 1800.0,
"chargeTotalImport": 98.765,
"chargeDuration": 3600000000000
},
{
Expand All @@ -34,6 +36,7 @@
"chargeVoltages": [230, 230, 230],
"effectiveMaxCurrent": 16,
"chargedEnergy": 0.0,
"chargeTotalImport": 19341.908,
"chargeDuration": 0
}
]
Expand Down
75 changes: 72 additions & 3 deletions tests/test_dbus_service.py
Original file line number Diff line number Diff line change
Expand Up @@ -111,7 +111,8 @@ def test_update_connected_not_charging(monkeypatch):

def test_update_charging_uses_per_phase_voltages(monkeypatch):
svc, vedbus, _ = _make_svc(monkeypatch)
vedbus.__getitem__.return_value = 5
# /UpdateIndex starts at 5 (wraps to 6); other paths are uninitialised.
vedbus.__getitem__.side_effect = lambda k: 5 if k == "/UpdateIndex" else 0
lp = Loadpoint(
title="HeatingElement", connected=True, charging=True, mode="pv",
charge_power=4500.0,
Expand All @@ -132,13 +133,81 @@ def test_update_charging_uses_per_phase_voltages(monkeypatch):
assert sets["/Current"] == 19.5
assert sets["/MaxCurrent"] == 20
assert sets["/Mode"] == MODE_AUTO
# UNVERIFIED unit: chargedEnergy treated as Wh; must confirm against
# a live EVCC /api/state sample before merging the deploy.
# Fallback for EVCC payloads without chargeTotalImport.
assert sets["/Ac/Energy/Forward"] == 1.8
assert sets["/ChargingTime"] == 3600
assert sets["/UpdateIndex"] == 6


def test_update_prefers_charge_total_import_for_cumulative_energy(monkeypatch):
svc, vedbus, _ = _make_svc(monkeypatch)
vedbus.__getitem__.return_value = 0
lp = Loadpoint(
title="Heatpump", connected=True, charging=False, mode="off",
charge_power=90.25,
charge_currents=[0.93, 0.49, 0.5],
charge_voltages=[237.5, 236.9, 236.9],
charged_energy=0.0,
charge_total_import=19341.908,
)
svc.update(lp)
sets = dict(c.args for c in vedbus.__setitem__.call_args_list)
assert sets["/Ac/Energy/Forward"] == 19341.908


def test_update_energy_forward_is_monotonic_across_source_switch(monkeypatch):
"""EVCC may transiently return chargeTotalImport: null / 0 (e.g. on a
loadpoint without a meter). The fallback to chargedEnergy/1000 must not
roll /Ac/Energy/Forward backwards for VRM.
"""
svc, vedbus, _ = _make_svc(monkeypatch)

state = {"/Ac/Energy/Forward": 0.0, "/UpdateIndex": 0}
vedbus.__getitem__.side_effect = lambda k: state.get(k, 0)
vedbus.__setitem__.side_effect = lambda k, v: state.__setitem__(k, v)

lp_high = Loadpoint(
title="Heatpump", connected=True, charging=True, mode="pv",
charged_energy=0.0, charge_total_import=19341.908,
)
svc.update(lp_high)
assert state["/Ac/Energy/Forward"] == 19341.908

# EVCC transiently drops the meter value; chargedEnergy is 0 on a heating LP
lp_drop = Loadpoint(
title="Heatpump", connected=True, charging=True, mode="pv",
charged_energy=0.0, charge_total_import=0.0,
)
svc.update(lp_drop)
assert state["/Ac/Energy/Forward"] == 19341.908 # held, no regression

# Meter value comes back and grows
lp_resume = Loadpoint(
title="Heatpump", connected=True, charging=True, mode="pv",
charged_energy=0.0, charge_total_import=19500.0,
)
svc.update(lp_resume)
assert state["/Ac/Energy/Forward"] == 19500.0


def test_update_disconnected_with_total_import_still_publishes_cumulative(monkeypatch):
"""A disconnected loadpoint with a positive chargeTotalImport (e.g. an
EV that just unplugged) should still publish the lifetime counter so
VRM history doesn't stall on disconnect. /ChargingTime stays unpublished.
"""
svc, vedbus, _ = _make_svc(monkeypatch)
vedbus.__getitem__.return_value = 0
lp = Loadpoint(
title="Carport", connected=False, charging=False, mode="pv",
charged_energy=0.0, charge_total_import=15303.908,
)
svc.update(lp)
sets = dict(c.args for c in vedbus.__setitem__.call_args_list)
assert sets["/Status"] == STATUS_DISCONNECTED
assert sets["/Ac/Energy/Forward"] == 15303.908
assert "/ChargingTime" not in sets


def test_update_index_wraps_at_255(monkeypatch):
svc, vedbus, _ = _make_svc(monkeypatch)
vedbus.__getitem__.return_value = 255
Expand Down
2 changes: 2 additions & 0 deletions tests/test_evcc_api.py
Original file line number Diff line number Diff line change
Expand Up @@ -30,6 +30,7 @@ def test_fetch_state_returns_loadpoints_1lp(requests_mock):
assert lp.charge_currents == [6.5, 0, 0]
assert lp.effective_max_current == 20
assert lp.mode == "pv"
assert lp.charge_total_import == 12.345


def test_fetch_state_returns_loadpoints_3lp(requests_mock):
Expand Down Expand Up @@ -90,6 +91,7 @@ def test_missing_optional_fields_use_defaults():
assert lps[0].charge_currents == [0, 0, 0]
assert lps[0].connected is False
assert lps[0].charge_power == 0.0
assert lps[0].charge_total_import == 0.0
assert lps[0].effective_max_current == 16